Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1985, Graco Inc. is registered to I.S. EN ISO 9001 55 GALLON SUPPL Y PUMPS 3:1 President r , 4:1 President r , and 2:1 Monark r With drum cover and agitator Model 220575, Series B with 3:1 Ratio President Pump 500 psi (3.
2 307745 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup Grounding 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positioning the Unit 5 . . . . . . . . . . . . . .
307745 3 W ARNING MOVING P ARTS HAZARD D The air motor piston can pinch or amputate your fingers. D The rotating blades of the agitator can pinch or amputate your fingers or other body parts and can cause splashing in the eyes or on the skin.
4 307745 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
307745 5 Setup NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. D Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.
6 307745 Setup The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco representative for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories D Ground the unit as described in Grounding on page 5.
307745 7 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
8 307745 Operation 8. Shut off the air to the pump, open the bleed–type master air valve, and open the drain valve (K). Leave the solvent in the system overnight or , if possible, all weekend. 9. Start the pump and circulate it again for 30 min- utes.
307745 9 Operation Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Never allow paint to dry in the pump and lines. T o shutdown the system 1.
10 307745 Parts Drawing c Fig. 3 1 or 5 2 3 6 (MONARK PUMP SHOWN) 10 9 8 11 Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 1 1 Model 230992, Seri.
307745 1 1 Parts List Model 230992, Series B 4:1 Ratio President Carbon Steel 55 Gallon Drum System Includes items 1 to 4, and 6 to 12 Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 1 1 Ref. No. Part No.
12 307745 Parts Drawing 7679A Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Includes items 1–35 Ref No. 6 includes items 6a–6d. Ref No. 5 includes items 5a–5c. 1 2 5a 35 3 6a 6b,6c 6d 4 1 2 Remove and discard 1/2 x 3/8 npt nipple from outlet of air regulator (5a), and replace with 1/2 npt nipple (5c).
307745 13 Parts List Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Ref Part No. No. Description Qty 1 220564 PUMP , President See 308793 for parts 1 2 237309 COVER, drum, 55 gal.
14 307745 Notes.
307745 15 T echnical Data Category Model 220575 Model 230992 Model 230993 Ratio 3:1 4:1 2:1 Maximum fluid working pressure 500 psi (3.5 MPa, 35 bar) 400 psi (2.8 MPa, 28 bar) 200 psi (1.4 MPa, 14 bar) Maximum air input pressure 166 psi (1.2 MPa, 1 1.6 bar) 100 psi (0.
16 307745 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Een belangrijk punt na aankoop van elk apparaat Graco 230993 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Graco 230993 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Graco 230993 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Graco 230993 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Graco 230993 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Graco 230993 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Graco 230993 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Graco 230993 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.