Gebruiksaanwijzing /service van het product 6000V van de fabrikant Americair
Ga naar pagina of 16
READ AND SA VE THESE INSTRUCTIONS! Please read instructions before installing and using the HEP A Bypass Air Filtration System (HEP A system). This will help you obtain the full benefit of the HEP A sys- tem you have selected. It will also help you to avoid needless service costs.
2 T able of Contents Rules for Safe Installation and Operation ................1 Shipping and Packing List ........................................1 Specifications ..........................................................2 Introduction ..............
Media Filters Media filters strain particulates from the air . The filter media needs to have tiny holes to allow air to pass through, but not particulates. Filter types vary for all sorts of purposes. The most ef fective and proven filter media is HEP A.
4 Parts Identification 2500HV 4000HV Parts Identification 6000V Filter Section Access Panel Retaining Clips (4) 6” Intake Collar Cabinet 6” Outflow Collar On/Off Switch Motor Section Access Panel Cabinet Parts Inside Cabinet (Filter Section) Inside Cabinet (Filter Section) figure 1.
5 Parts Identification 6500, 8500 & 10000 Cabinet Parts 10”x12” Outflow Duct V ariable Speed Switch 10”x12” Intake Duct Filter Section Access Panel Motor Section Access Panel Finger T abs (4) Cabinet Inside Cabinet (Filter Section) figure 5.
6 HEP A Filter Pre-Filter - Foam HEP A Filter Mesh (Protects HEP A Filter) Inner Carbon Filter For third stage increased removal of chemicals and odors. Located inside the HEP A filter . Discard inner carbon filter when using the optional carbon canister .
7 Physical Dimensions of Unit E K K G C F B H I J A D MODEL NO. ABCD E F G H I J K Model 2500HV 15.75 14 16.25 6 6 15.75 1.75 1.25 1.5 1.5 8 (400) (356) (413) (152) (152) (400) (44) (32) (38) (38) (203) Model 4000HV 15.75 14 25 6 6 15.75 1.75 1.25 10.
8 Physical Dimensions of Unit Banvil OFF LOW MODEL NO. ABCD E F G H I J Models 6500, 8500 17.25 28 47.75 10 12 50.25 2.5 2.6 5.3 0.1 & 10000 (438) (71 1) (1213) (254) (254) (1276) (64) (66) (135) (3) Dimensions in inches (mm) figure 13.
T ypical Return to Return Application For homes with horizontal forced air handler/furnace systems. (Air handler/furnace is shown in an typical attic. See figure 7.) T ypical Return to Return Application For homes with upflow forced air handler/furnace sys- tems.
Preparation: Here are some things to consider as you decide where to install the HEP A system with an HRV/ER V . Location: • Make sure there is room to open the HEP A filter access panel for filter changes/inspections. • Keep the HEP A system in a location where you can still access the air han- dler/furnace filter .
Independent Operation: The HEP A systems can be used independently of any other equipment! The intake and outflow of the filtration system can be ducted into the same room to create a cleaner environment almost anywhere. The intake or out- flow can also be ducted elsewhere.
12 Operation Maintenance 1. Make sure that the unit is plugged into a grounded outflow (120 V olt, 60 Hz). 2. For optimum performance, the HEP A system should operate when the indoor air handler/furnace blower is on. 3. For model 2500HV & 4000HV : T urn the unit on by pressing the on/off switch to the ‘1’ position.
13 Dealer Filter Change Instructions - 2500HV , 4000HV & 6000V It is recommended that gloves and a filtered breathing mask be worn during filter replacement to avoid breathing particulates (dust, mold, pollen, etc.) captured on the filter that become airborne during the filter(s) changeout.
14 Dealer Filter Change Instructions - 6500, 8500 & 10000 It is recommended that gloves and a filtered breathing mask be worn during filter replacement to avoid breathing particulates (dust, mold, pollen, etc.) captured on the filter that become airborne during the filter(s) changeout.
1. Accessing the motor assembly a. T urn the unit off and unplug it from any electrical source before opening the cabinet. b. Remove the safety screw(s) from the motor section access panel. c. Lift the door up by the finger tabs and pull out to remove it from the unit.
16 Replacement Parts Replacement Parts for 2500HV & 4000HV (Qty .) Canadian U.S. International Complete Filter Kit - 2500HV (1 Pre-filter , 1 HEP A, 1 Carbon) 9100723709 9101723709 9101723709 Comp.
Een belangrijk punt na aankoop van elk apparaat Americair 6000V (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Americair 6000V heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Americair 6000V vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Americair 6000V leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Americair 6000V krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Americair 6000V bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Americair 6000V kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Americair 6000V . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.