Gebruiksaanwijzing /service van het product APB-330V2 van de fabrikant Grindmaster
Ga naar pagina of 44
Shuttle ® Brewer & Airpot/Shuttle ® Brewers Operation and Instruction Manual For Models APB-330V2, APB-430V2, APBVSA-330V2, APBVSA-430V2, APBIC-330V2, APBIC-430V2, APB-330V2E230, APB-430V2E230, APBVSA-330V2E230, APBVSA-430V2E230, APBIC-330V2E230, PBIC-430V2E230 T able of Content s W arning Labels .
.
W arning Labels The following warning labels were on your dispenser when it was shipped from the factory . They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replacement label immediately .
Page 4 Shuttle Brewers & Airpot/Shuttle Brewers Inst allation W ARNING ELECTRIC SHOCK HAZARD! Inst allation of this appliance should be performed by qualified service personnel only . Improper inst allation could result in electrocution. Set-Up/Position 1) Remove the brewer from the packing material and att ach its legs.
Shuttle Brewers & Airpot/Shuttle Brewers Page 5 Inst allation (cont.) Electric Hook-up The brewer is designed to operate at the specified voltage on the nameplate with a tolerance of ± 10% for volt age deviation.
Page 6 Shuttle Brewers & Airpot/Shuttle Brewers Operation CAUTION HOT LIQUID HAZARD! W ater used for brewing coffee is very hot. Use caution when brewing, pouring, or transporting coffee. Accident al spills may result in severe burns. 1) Place an empty , warm Shuttle on the shelf, under the brew head.
Shuttle Brewers & Airpot/Shuttle Brewers Page 7 Adjustment s All adjustments to machine are accessible through the front display(s). Refer to specifics below and the Programming Routine section. All values are preset at the factory and may vary brewer to brewer .
Page 8 Shuttle Brewers & Airpot/Shuttle Brewers Adjustment s (cont.) Brew V olume “br” Brew time can be set for each size visually . See Setting Brew V olume Procedure below . Brew time can also be adjusted through the display . See Programming Routine section.
Shuttle Brewers & Airpot/Shuttle Brewers Page 9 Programming (cont.) T o program the following items, press the Large, Right side portion button. (refer to T able 1) 1) T emperature Scale: Choose .
Page 10 Shuttle Brewers & Airpot/Shuttle Brewers Programming (cont.) 13) By-P ASS (Set bypass volume): Choose OFF to 25% Set the amount of bypass desired during brew . If none is desired then set to OFF , otherwise, set the % of brew volume to bypass.
Shuttle Brewers & Airpot/Shuttle Brewers Page 11 Programming Sequence for Large Lef t Portion T able 1 PRE IN FUSI ON PRE IN FUSI ON TIME (OFF TO 2.
Page 12 Shuttle Brewers & Airpot/Shuttle Brewers Programming Sequence for Large Lef t Portion (cont.) T able 1 (cont.) PRE IN FUSI ON ADJ US T TO PULSE OF F TIME (0: 05-2:00) PULSE ON TIME (0: 05-2:00) COPY T O LEFT # OF PUL SES OR REA DING DISPL AY ADV ANC E PULSE ON PULSE OF F BY-P A SS OFF T O .
Shuttle Brewers & Airpot/Shuttle Brewers Page 13 Programming Sequence for Medium Portions T able 2 .
Page 14 Shuttle Brewers & Airpot/Shuttle Brewers Programming Sequence for Medium Portions (cont.) T able 2 (cont.) DISPLA Y WILL RE AD A S FOLLOW S: COPY T O LEFT PRES S- AND- HOLD UP & DO WN A RROW S FOR 5 S ECONDS .
Shuttle Brewers & Airpot/Shuttle Brewers Page 15 Programming Sequence for Small Portions T able 3 PRESS-AND-H OLD U P & DOWN ARROWS FOR 5 SECOND S. DISPLA Y WILL RE AD A S FOLLOW S: ADV ANC E (O F F, 1 - 10 ) ADJ US T REA DING OG G O S S (.05 TO 2.
Page 16 Shuttle Brewers & Airpot/Shuttle Brewers Cleaning W ARNING Burn Hazard! Hot liquids and surfaces are present in this equipment. T o avoid burns use caution when cleaning. Rinse hot p arts with cold water before cleaning. Use gloves or a heavy cloth when removing hot p arts from brewer .
Shuttle Brewers & Airpot/Shuttle Brewers Page 17 Service The rest of this manual contains information to aid the service person who is working on this equipment.
Page 18 Shuttle Brewers & Airpot/Shuttle Brewers Special Control Functions User Lockout User Lockout is achieved via the position of the LOCK jumper on the board header . Locate the header on the board (shown below) and place the jumper in the desired position.
Shuttle Brewers & Airpot/Shuttle Brewers Page 19 Factory/Field T est Menu (cont.) Step Function Operation Description 1 LED T est All LEDs ON V erify that all LEDs turn on. 2 Firmware V ersion Display firmware version Shows the software version of the control.
Page 20 Shuttle Brewers & Airpot/Shuttle Brewers T roubleshooting The following pages are provided to help determine the cause of problems with operation of the brewers and to indicate the appropriate solution for the problems.
Shuttle Brewers & Airpot/Shuttle Brewers Page 21 T roubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy T ank does not refill • No electrical power to equipment • No water supplied to equipment • No power to control board • No power to control board and transformer not powered.
Page 22 Shuttle Brewers & Airpot/Shuttle Brewers T roubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy T ank does not refill • Fill valve or control board is faulty • Check to ensure proper connection between 6 pin connector and con- trol board.
Shuttle Brewers & Airpot/Shuttle Brewers Page 23 T roubleshooting (cont.) Heating Problems Problem Possible Causes Service Check Remedy T ank does not heat • Low (long) electrode coated with lime or faulty . • Connection from control board to tank body faulty .
Page 24 Shuttle Brewers & Airpot/Shuttle Brewers T roubleshooting (cont.) Heating Problems Problem Possible Causes Service Check Remedy T ank does not heat • Contactor faulty .
Shuttle Brewers & Airpot/Shuttle Brewers Page 25 T roubleshooting (cont.) Brewing Problems Problem Possible Causes Service Check Remedy Brew volume too large or too small • S prayhead clogged. • Brew valves clogged with lime deposits. • W ater supply pressure or flow rate not adequate.
Page 26 Shuttle Brewers & Airpot/Shuttle Brewers T roubleshooting (cont.) Brewing Problems Problem Possible Causes Service Check Remedy Brew cycle will not st art • Controller faulty . • Check to see that the power is supplied to the controller by following instructions given in the T roubleshooting section on Filling Problems.
Shuttle Brewers & Airpot/Shuttle Brewers Page 27 ITEM DESCRIPTION P ART # Reference Front View Picture: 1 Controller PB A530-066 2 Relay , Heater* A71450 3 W ater Inlet V alve 24 V AC A725-1 17 4 .
Page 28 Shuttle Brewers & Airpot/Shuttle Brewers Front V iew (refer to key on page 27) Lower W armer (refer to key on page 27) (APB-430V2 pictured) 23 23 22 21 20 21 22 6 5 1* 7 3 4 2.
Shuttle Brewers & Airpot/Shuttle Brewers Page 29 T op V iew (refer to key on page 27) 42 30 34 T ank Lid (refer to key on page 27) 3 Heater Model shown 50 52 51 50 36 35 38 35 32 36 52.
Page 30 Shuttle Brewers & Airpot/Shuttle Brewers ITEM DESCRIPTION P ART # 1 Faucet Model ES A537-053 2 Shank w/ Chrome Bonnet A522078 3 Gauge Assembly A718-018 4 Kit, Shuttle Lid A725-092 S.S. Shuttle Cover (not shown)* A713-027 5 Lid Retaining Clip A548-142 6 Lid S topper w/ O-Ring A548-140 A61365 * S.
Shuttle Brewers & Airpot/Shuttle Brewers Page 31 VS-1.5S VS-S 3 1 8 5 2 9 6 7 4 5 1 4 6 2 3 7 8 ITEM NO. Title PART NUM BER VS-1.5S/QTY. 1 Stand Body A548-157 1 2 Tray for Sta nd A548-159 1 3 Vacuum Shuttl e VS-1.5 1 4 Sta nd Base A548-158 1 5 Tray Top A517-018 1 6 Self-Tapping Screw .
Page 32 Shuttle Brewers & Airpot/Shuttle Brewers These cleaning and sanitizing instructions are only a guideline to be used for the cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5. In-house cleaning and sanitizing methods may be more effective.
Shuttle Brewers & Airpot/Shuttle Brewers Page 33 Wiring Diagram - Precision Brew 430 Series Models APB-430V2, APBVSA-430V2, and APBIC-430V2.
Page 34 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram - Precision Brew 330 Series Models APB-330V2, APBVSA-330V2, and APBIC-330V2.
Shuttle Brewers & Airpot/Shuttle Brewers Page 35 Wiring Diagram APB-430V2E230, APBVSA-430V2E230, APBIC-430V2E230 (Single or Three Phase Models).
Page 36 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 Brewers.
Shuttle Brewers & Airpot/Shuttle Brewers Page 37 Wiring Diagram - Precision Brew 430 Series 120/208 or 120/240V Models APB-430V2, APBVSA-430V2, and APBIC-430V2 6((+($7(5&21),*62127+(56+((7 %5(:9$/9(/()7YDF 9$/9(YDF :$7(5,1/(7 :$7(57$1.
Page 38 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram - Precision Brew 330 Series 120/208V , 120/240V Models APB-330V2, APBVSA-330V2, and APBIC-330V2 9$ / 9( Y DF :$ 7 (5 ,1/ ( 7 :$ 7 (5 7 $ 1.
Shuttle Brewers & Airpot/Shuttle Brewers Page 39 Wiring Diagram 230V , 208V , or 240V without Neutral Models APB-430V2, APBVSA-430V2, APBIC-430V2, APB-430V2E230, APBVSA-430V2E230, and APBIC-430V2E230 6((+($7(5&21),*62127+(56+((7 %5(:9$/9(/()7YDF 9$/9(YDF :$7(5,1/(7 :$7(57$1.
Page 40 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram 230V , 208V , or 240V without Neutral Models APB-330V2, APBVSA-330V2, APBIC-330V2, APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 9$ / 9( Y DF :$ 7 (5 ,1/ ( 7 :$ 7 (5 7 $ 1.
Shuttle Brewers & Airpot/Shuttle Brewers Page 41 Wiring Diagram - Heater Configuration (3 Heater).
Wiring Diagram - Heater Configuration (1 Heater) Page 42 Shuttle Brewers & Airpot/Shuttle Brewers.
Shuttle Brewers & Airpot/Shuttle Brewers Page 43 Control Board all PrecisionBrew™ V2.0 models Refers to software version number . Subject to change.
T el (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 (USA & Canada only) P .O. Box 35020 • Louisville, KY 40232 • USA www .grindmaster .
Een belangrijk punt na aankoop van elk apparaat Grindmaster APB-330V2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Grindmaster APB-330V2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Grindmaster APB-330V2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Grindmaster APB-330V2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Grindmaster APB-330V2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Grindmaster APB-330V2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Grindmaster APB-330V2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Grindmaster APB-330V2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.