Gebruiksaanwijzing /service van het product P400ESHP van de fabrikant Grindmaster
Ga naar pagina of 36
Shuttle Brewer & Airpot/Shuttle Brew ers Operation and Instruction Man u al For Models P300E, P400E, P400ESHP , RAP300E, RAP400E, RAPS300E, RAPS400E Inst allation: See rough-in drawings in this manual for di men sions and lo ca tions of electric and water input.
Page 2 Shuttle Brewers & Airpot/Shuttle Brewers Inst allation (con't) Electric Hook-up 1) The electric ratings for your brewer are printed on its nameplate. T ypical electric ratings are: P300, P400, RAP300, RAP400 Optional 120/208V , 3.8kW , 18A or 120/240V 5.
Page 3 Shuttle Brewers & Airpot/Shuttle Brewers W arning Labels The following warning labels were on your dispenser when it was shipped from the factory . They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replacement label immediately .
Page 4 Shuttle Brewers & Airpot/Shuttle Brewers Operation 1) RAPS Brewers require the accessory warmer base placed over the pegs on the brew shelf before brewing into a shuttle. Plug the base into the receptacle on the side of the brewer . The recept acle is only energized when a shuttle is in place.
Page 5 Shuttle Brewers & Airpot/Shuttle Brewers Adjustment s All adjustable component s are located under the top cover . T o access these part s: 1) Shut off the electric line to the brewer or unplug the brewer . 2) Remove the single screw fastening the top cover .
Page 6 Shuttle Brewers & Airpot/Shuttle Brewers T wo Batch Timer with Knob Adjustment, See Figure 2: This timer is adjustable from 15 seconds to 5 minutes. Locate the adjustment knobs under the top cover . Set this timer by adjusting the knob. The batch selector switch picks the adjustment potentiometer which the timer will see.
Page 7 Shuttle Brewers & Airpot/Shuttle Brewers T o Adjust the Byp ass: 1) Shut off and open brewer as described at the beginning of the adjustment s section. 2) Locate the bypass valve for the brew head you wish to adjust. V alve is on the right and front of the BREW valve.
Page 8 Shuttle Brewers & Airpot/Shuttle Brewers 4) If the maximum temperature adjustment needs to be increased, insert a small flat screwdriver into the shaft. T urn the calibration screw counter clockwise to increase the maximum temperature. Optional Solid S tate Thermostat: This control maint ains temperature within 3°F .
Page 9 Shuttle Brewers & Airpot/Shuttle Brewers Cleaning Af ter Each Brew: 1) Dispose of grounds and rinse brew basket. 2) Rinse shuttle or airpot containers before reuse. Every Day: 1) W ash brew basket with warm soapy water . The wire basket is removable to aid cleaning.
Page 10 Shuttle Brewers & Airpot/Shuttle Brewers Weekly or Bi-W eekly , Depending on Use 1) Fill shuttles with one gallon, 2/3 full, of hot water . 2) Pour into the shuttle liners the recommended concentration of urn cleaner (excessive amounts of cleaner will attack the st ainless steel).
Page 1 1 Shuttle Brewers & Airpot/Shuttle Brewers Service (con't) Drain W ater T ank Always empty the tank before shipping. Note: Brewer may cont ain over 5 gallons of hot water . 1) Prepare a heat resist ant container to drain t ank water into.
Page 12 Shuttle Brewers & Airpot/Shuttle Brewers T roubleshooting: Filling, Heating, and Brewing Overfilling water t ank even when power is off. Fill valve not sealing properly . Fill valve installed backwards. W ater entering tank continuously , usually slowly .
Page 13 Shuttle Brewers & Airpot/Shuttle Brewers If you still need help, call our T echnical Service Department at (502) 425-4776 or (800) 695-4500 (USA & Canada only) Monday thru Friday 8 am - 8 pm EST or an authorized service center in your area.
Page 14 Shuttle Brewers & Airpot/Shuttle Brewers T roubleshooting: Filling, Heating, and Brewing Brewing Problems The brewing system consists of the following component s: • S tart and S top, switches located in the top control panel. • Brew T imer , located in the top control section under the top cover .
Page 15 Shuttle Brewers & Airpot/Shuttle Brewers Part s Illustration for Models P300E & P400E Item Part # Description Item Part # Description 1 A545-034 LEG , 4” PLASTIC W/ SS FOOT 13 A725-0.
Page 16 Shuttle Brewers & Airpot/Shuttle Brewers Part s Illustration for Model P400ESHP Item Part # Description Item Part # Description 1 A545-034 LEG , 4” PLASTIC W/ SS FOOT 15 A585-021 SPRA Y .
Page 17 Shuttle Brewers & Airpot/Shuttle Brewers Part s Illustration for Model RAP400E Item Part # Description Item Part # Description 1 A548-072 LEG , RUBBER (RAP400) 11 A515016 PILOT LIGHT 1 A54.
Page 18 Shuttle Brewers & Airpot/Shuttle Brewers Part s Illustration for Model RAPS400E FRONT Item Part # Description Item Part # Description 1 A545-034 LEG , 4” PLASTIC W/ SS FOOT 16 A725-081 B.
Page 19 Shuttle Brewers & Airpot/Shuttle Brewers Part s Illustration for Model VSB-400 Item Part # Description Item Part # Description 1 A545-034 LEG , 4” PLASTIC W/ SS FOOT 12 A725-081 SPRA Y T.
Page 20 Shuttle Brewers & Airpot/Shuttle Brewers Part s Illustration for Shuttle CS-LL Item Part # Description 1 A537-053 F AUCET MODEL ES 2 A522078 SHANK W/ CHROME BONNET 3 A718-018 GAUGE ASSEMBL Y 4 A725-092 KIT , SHUTTLE LID A713-027 SS SHUTTLE COVER (not shown)* 5 A548-142 LID RET AINING CLIP 6 A548-140 A61365 LID STOPPER W/ O-RING * S.
Page 21 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model P-300.
Page 22 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model P-400 & P-400ESHP.
Page 23 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model RAP-300.
Page 24 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model RAP-400.
Page 25 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model RAPS-300.
Page 26 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model RAPS-400.
Page 27 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model VSB-300 W W W W W A TER IM S.
Page 28 Shuttle Brewers & Airpot/Shuttle Brewers Rough-In Drawing for Model VSB-400.
Page 29 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram for P300E/P400E, with 1 Batch T imer NOTE: THIS DRA WING SHOWS COMPONENTS ON ST ANDARD MODEL ONL Y .
Shuttle Brewers & Airpot/Shuttle Brewers Page 30 Wiring Diagram for P300E/P400E, with 2 Batch T imer NOTE: THIS DRA WING SHOWS COMPONENTS ON ST ANDARD MODEL ONL Y .
Page 31 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram for RAP300E/400E NOTE: THIS DRA WING SHOWS COMPONENTS ON ST ANDARD MODEL ONL Y . SEE 091-548 FOR WIRING OF BREWER OPTIONS Drawing #0.
Page 32 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram for RAPS 300/400E NOTE: 1) TWO SETS OF RECEPT ACLE COMPONENTS ONL Y PROVIDED ON TWIN RAPS400E MODEL. DELETE GROUP I N DASHED BOX FOR RAPS300E. 2) THIS DIAGRAM SHOWS COMPONENTS ON ST AN - DARD MODEL ONL Y .
Page 33 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram for P-400ESHP.
Page 34 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram #091-548 NOTE: 1) ONE GROUP OF W ARMER COMPONENTS PER BREW HEAD ON P AND RAPS MODELS. 2) TRANSFORMER MUST BE USED WHEN NEUTRAL LINE IS NOT PROVIDED. 3) IF MODEL RAP , DELETE W ARMER COMPONENTS.
Page 35 Shuttle Brewers & Airpot/Shuttle Brewers Wiring Diagram #091-182 T3 T3 T3 1 1 T4 A T2 T3 T3 T4 T4 T4 B T2 T3 T3 1 1 T1 C T3 T3 T3 T1 T1 T4 D T2 T3 T3 T1 T1 T4 E T2 T3 T3 T1 T1 T2 F NOTE: USE WIRE NUT FOR 1 - 1 CONNECTION 5000 W A TT / 240V HEA TERS * SEP ARA TE 120V REQUIRED FOR CONTROLS (3 AMP LOAD) 2.
Grindmaster® Coffee Grinders and Br ewers • PrecisionBr ew™ Brewing Systems • Espr essimo® Espresso Machines Crathco® Hot Beverage Dispensers • Crathco® Cold and Frozen Beverage Dispensers • AMW Cof fee and T ea Systems T el (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 (USA & Canada only) P .
Een belangrijk punt na aankoop van elk apparaat Grindmaster P400ESHP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Grindmaster P400ESHP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Grindmaster P400ESHP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Grindmaster P400ESHP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Grindmaster P400ESHP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Grindmaster P400ESHP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Grindmaster P400ESHP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Grindmaster P400ESHP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.