Gebruiksaanwijzing /service van het product PNEG-1153 van de fabrikant GSI Outdoors
Ga naar pagina of 46
PNEG-1153 CALC-U-DRI MOISTURE/MA TIC/MANAGER Owner ’ s Manual PNEG-1153 Date: 03-20-07.
2 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 3 T able of Content s Contents Chapter 1 Introduction ... ................ ................. ............ ................. ................ ................ ...... ............. ... 4 Chapter 2 Safety ....
4 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 1. INTRODUCTION DMC’s Calc-U-Dri Moisture/Matic is a grain dr ying control specifically designed for continuous flow, out-of-bin grain dryers with an SCR control and a DC motor on the metering ro lls.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 5 2 . S A F E T Y SAFETY INFORMATION PLEASE READ. WATCH FOR THIS SYMBOL! IT POINTS OUT IMPORTANT SAFETY PRECAUTIONS.
6 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 3. SAFETY DECALS 1. Read and understand the Owner’s Manual. 2. Disconnect all electrical power before se rvicing or opening control box, adjusting or lubricating the equ ipment. 3. All electrical hook-ups should be in ac corda nce to the National Electrical Code.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 7 4 . I N S T A L L A T I O N Sensor Location and Cutout Instructions Sensor Location Locations for sensor installation a re dependent on the following factors all being pre sent for proper operation. (See Figure 4A).
8 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 4. INST ALLATION Sensor Cutout Instructions Sensor Cut-Out Instructions for Six (6)" a nd Eight (8)" Augers DISCONNECT POWER TO THE AUGER MOTOR BEFORE PROCEEDIN G ANY FURTHER! 1. Look at the discharge tube and determine where the sensor can be located.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 9 4. INST ALLATION 2. Position the sensor connecting band on the discharg e tube so that the rectangular hole is toward the discharge end. Mark the outline of the rectangular hole and the edg es of the band on the discharge auger tub e.
10 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 4. INST ALLATION Figure 4E Note: If there is more than 5/8" gap b etween the bottom pan and the outer edge of the flighting, do not use a sensor in that location. Use another location, such as a take-away auger.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 1 1 4. INST ALLATION Figure 4G 5. On the flat bottom pan, make some filler pi eces 12" long to keep the grain closer to the sensor flag. See Figure 4G, See Figure 4 H, and See Figure 4I. Be sure the leading edge is closed so grain cannot get under the piec es.
12 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 4. INST ALLATION SLOWLY ROTATE THE AUGER BY HAND ONE COMPLETE REVOLUTION. THE FLIGHTING MUST MISS THE GAUGE COMPLETELY AND NOT RUB ON THE FILLER PIECES. IF THERE ARE AREAS OF BINDING OR HITTING, CORRECT THE SITUAT ION NOW.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 13 4. INST ALLATION Figure 4K 3. Secure the restrictor spout to the flat bottom with 1/4" hardware. Secure the sensor by cutting the end off of the strap and mounting with a self-drilling screw to the edg e of the flat spout.
14 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 4. INST ALLATION 4. For conditions where straw or chaff can accu mulate in the re strictor funnel, the grain can be channeled over the sensor with angled brackets in the down spout. (See Figure 4N). Figure 4N Sensor Cut-Out for Round Down Spout s 1.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 15 4. INST ALLATION Figure 4O 5. Secure the Calc-U-Dri sensor wire to the inside of the Calc-U-Dri Mo isture/Matic box with the plastic “J” clips. Connect th e sensor wires to the terminal strip marked “sensor”.
16 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 4. INST ALLATION b. In the Moisture/Matic contro l box, loca te the five (5) post terminal. This has “DC Voltmeter” written on it. The green wire should be placed on t erminal one (1) and the black on terminal two (2).
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 17 4. INST ALLATION 4. 115 Volts A/C Hook-Up a. The Calc-U-Dri Moisture/Matic requires 1 15 Volts AC. This can be on an indep endent circuit or taken from a control bo x which would automatically tu rn the Calc-U-Dri on when the dryer is on.
18 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 5. S T ART-UP AND OPERATION 1. Place the Automatic/Monitor switch in the “Monitor” position and turn the Moisture/Matic “ON”. The power indicator light should come on; if not, check the AC power input and/or Trouble Shooting Guide.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 19 5. S T ART-UP AND OPERATION d. Why take several samples? The electronics average t he grain moisture and therefore it is possible to have a sample that is either wetter or dryer than the meter is reading (if the meter is changing rapidly while sampling).
20 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 5. S T ART-UP AND OPERATION 8. The amount of speed chan ge from “Main” speed to either “Low” or “High” speed can b e varied by using the “Speed Adjustme nts” loca ted by the indicators. A speed change of approximately 15% sh ould give good performance under most conditions.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 21 6 . P R I N T E R I N S T A L L A T I O N ( O P T I O N A L ) 1. Disconnect all power (AC). 2. Remove the hole cover by removing the six (6) #8-32 screws holding it in. 3. Install the printer Wiring Decal 602L065 on the back of the inside door.
22 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 6. PRINTER INST ALLATION (OPTIONAL) Figure 6A.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 23 6. PRINTER INST ALLATION (OPTIONAL) 11. Plug in the printer control cable to the printer a ssembly. 12. Wire the printer power supply wire to the pr inter assembly. Connect the red wire to #1, green wire to #2.
24 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 6. PRINTER INST ALLATION (OPTIONAL) Service for Modular Printer Assembly If removal of the circuit board is necessary, follow these st eps. 1. Disconnect AC power to the control box. 2. Carefully pull the circuit board straight out o f the guides.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 25 7 . W I R I N G D I A G R A M S Wiring Diagram for Moisture/Matic Figure 7A.
26 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 7. WIRING DIAGRAMS Wiring Diagram for Mo isture/Matic Printer Figure 7B.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 27 8 . P A R T S L I S T 1. Moisture/Matic/Mana ger Module Subassembly 2. Moisture/Matic/Mana ger Control Box (Plain) 3.
28 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 8. PART S LIST Moisture/Matic/Manager Module Subassembly.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 29 8. PART S LIST Moisture/Matic/Manager Module Subassembly Ref # Part # Qty Description 1 5041 198 1 Digital Panel Meter Kit Includes Wires 2 1EL0719 1 Fu.
30 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 8. PART S LIST Moisture/Matic/Manager Control Box (Plain).
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 31 8. PART S LIST Moisture/Matic/Manager Control Box (Plain) Ref # Part # Qty Description 1 1EL0879 1 T erminal Block - 2 T erm, 30 Amp, 250 V olt 2 1EL0898 1 T erminal Block - 5 T erm, 30 Amp, 250 V olt 3 1EL0900 2 T erminal Block - 12 T erm, 30 Amp, 250 V olt 4 2EL0274 3 Relay - Gen.
32 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 8. PART S LIST Moisture/Matic/Manager Control Box (Pri nter).
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 33 8. PART S LIST Moisture/Matic/Manager Control Box (Printer) Ref # Part # Qty Description 1 1EL0854 1 Connector - Circuit Board 36 Circuits 2 1EL0879 1 T.
34 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 8. PART S LIST Printer Module Subassembly.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 35 8. PART S LIST Printer Module Subassembly Ref # Part # Qty Description 1 602E184 1 Printer Module 2 2EL0299 1 Keyboard - 12 Button 3 602E155 1 Printer -.
36 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 8. PART S LIST Calc-U-Dri Moisture/M atic/Manager Part s.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 37 8. PART S LIST Calc-U-Dri Moisture/Matic/Manager Part s Ref # Part # Qty Description 1 602C040 1 6" OD Calc-U-Dri Connecting Band 2 603C021 1 8&quo.
38 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 9. T ROUBLESHOOTING GUIDE Problem Possible Cause Solution 1. Digital readout dead. 1. Main AC power OFF . 2. Main fuse(s) or control fuse blown. 3. Circuit board not plugged in. 4. Bad circuit board. 5. Power supply not working.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 39 9. T ROUBLESHOOTING GUIDE Note: 1. Never unplug or plug in the circuit board with power “ON”. 2. Do not make field adjustments on the circuit board. This is a factory adjustment only. 3. Contact your dealer or DMC if you have any qu estions on the service of your Ca lc- U-Dri Moisture/Matic.
40 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 10. WIRING EXAMPLES APPENDIX B Hooking Up a Moisture/Matic Control Box to a DMC or newer FFI GSI Port able Dryer NOTE: 1. Connect wires to bottom section of ter minal strip located in the upper control box.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 41 10. WIRING EXAMPLES Hooking Up a Moisture/Matic Control Box to a Beard Dryer with an Altivar Drive.
42 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 10. WIRING EXAMPLES Hooking Up a Moisture/Matic Control Box to a Farm Fans Series 2100 Dryer.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 43 10. WIRING EXAMPLES Hooking Up a Moisture/Matic Control Box to a Farm Fans Series CFS-SA 410 Dryer.
44 PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 10. WIRING EXAMPLES Hooking Up a Moisture/Matic C ontrol Box to a Farm Fans Series CF/AB 270 & 320 Dryer.
PNEG-1 153 CALC-U-DRI Moisture/Matic/Manager 45 1 1 . W A R R A N T Y THE GSI GROUP, INC. (GSI) WARRANTS ALL PRODUCTS WHICH IT MANUFACTU RES TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR A PERIOD OF 12 MONTHS AFTER RETAIL SALE TO THE ORIGINAL END USER.
T his equipment shall be in stalled in a ccor dance with the cur r ent installation codes and applicable re gulations wh ich should be carefull y follo wed in all cases. Authorities having jurisdiction should be consulted before installations are made.
Een belangrijk punt na aankoop van elk apparaat GSI Outdoors PNEG-1153 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GSI Outdoors PNEG-1153 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GSI Outdoors PNEG-1153 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GSI Outdoors PNEG-1153 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GSI Outdoors PNEG-1153 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GSI Outdoors PNEG-1153 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GSI Outdoors PNEG-1153 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GSI Outdoors PNEG-1153 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.