Gebruiksaanwijzing /service van het product 12 van de fabrikant GTO
Ga naar pagina of 40
Installation Manual f or the SINGLE Gate Opera tor S y stem PROFESSIONAL INST ALLA TION REC OMMENDED! W ARNING! This equipment is similar to other ga te or door equipment and meets or ex ceeds Under writers Laboratory Standard 325 (UL 325).
Class Rating The GT O 4000XLS G ate Operat or is intended for use with v ehicular swing gates in single family residential applications . The operator is syst em certied to be in compliance with UL 325, current edition, as of publication date .
T able of C ont ents Class Rating ...................................................................................................................... inside cov er Please Read This F irst ............................................................
ii GT O 4000XLS Instruction M anual © 01.10.12 Thank you f or purchasing a GTO/A CCESS SYSTEMS 4000XLS. When correctly installed and properly used , your 4000XLS operat or will give y ou many y ears of reliable service. Please read the f ollowing information to ensure y ou have the c orrect system for y our par ticular needs.
GT O 4000XLS Instruction M anual © 01.10.12 iii IMPORT ANT SAFETY INSTR UC TIONS Because automatic gate operators produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems.
iv GT O 4000XLS Instruction M anual © 01.10.12 IMPORT ANT SAFETY INSTR UC TIONS F or The Consumer W ARNING: T o reduce the risk of injury or death: 1. READ AND FOLL OW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual could cause severe injury or death, for which the manufacturer cannot be held responsible.
GT O 4000XLS Instruction M anual © 01.10.12 v IMPORT ANT SAFETY INSTRUCTIONS II. During Installation 1. Install the gate operator on the inside of the property and fence line. DO NOT install an operator on the outside of the gate where the public has access to it.
vi GT O 4000XLS Instruction M anual © 01.10.12 IMPORT ANT SAFETY INSTRUCTIONS 7. T o operate this equipment safely , YOU must know how to disconnect the operator for manual gate operation (page iii). If you have read the instructions and still do not understand how to disconnect the operator , contact the GTO Service Department.
GT O 4000XLS Instruction M anual © 01.10.12 vii IMPORT ANT SAFETY INSTRUCTIONS Secondary Means of Protection Against Entrapment As specified by Gate Operator Safety Standard, UL 325 (30A.
viii GT O 4000XLS Instruction M anual © 01.10.12 IMPORT ANT SAFETY INSTRUCTIONS ! W arning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate). Maximum Gate: 1000 lb. (453.5 kg); 20 ft. (6.1 m) V oltage: 12 Vdc; Frequency: 0 Hz; P ower: 60 W Class I V ehicular Swing Gate Operator .
GT O 4000XLS Instruction M anual © 01.10.12 1 T echnical Sp ecications GT O/AC CESS SYSTEMS 4000XLS A UT OMA TIC GA TE OPER A TOR DRIVE • Lowfrictionscrewdrive(linearactuator)ra tedfor-5ºFto+160ºF(-21ºCt o+71ºC).
2 GT O 4000XLS Instruction M anual © 01.10.12 Befor e Y ou B egin... 1. Determine Charging Option f or Battery: T ransf ormer OR S olar NEVER USE TRANSFORMER AND SOLAR P ANEL(S) A T THE SAME TIME.
GT O 4000XLS Instruction M anual © 01.10.12 3 2. Check Direction of G ate S wing The 4000XLS is designed f or PULL - T O- OPEN installations. PUSH- T O- OPEN installations requir e a Push- T o -Open Bracket [R4KPT O]. Please r efer to specic P ush- T o - Open Installation Information on page 21.
4 GT O 4000XLS Instruction M anual © 01.10.12 4. 4000XLS P ar ts List BRACKET BO X - HB4000 HARDW ARE BAG - H401P Master Oper ator Arm (1) PR O4000ARMXLS Customer Support Car d (1) ® E-Z GATE OPENER.
GT O 4000XLS Instruction M anual © 01.10.12 5 T ransformer (1) Battery (1) Control Box (1) Warning Signs (2) GTO T ransmitter(1) 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only.
6 GT O 4000XLS Instruction M anual © 01.10.12 7. Installation Overview Pull- T o- Open Gates (Gat e Opens into the Property) The diagram sho wn below is an example of a P ull- T o- Open installation on a chain link fence and single gate .
GT O 4000XLS Instruction M anual © 01.10.12 7 Step 1 Close the gate and place y our level against the horizontal cross member . P osition the level so that the t op should be in the center of the cr oss member and overlaps the post. Scribe a line across the cross member and post .
8 GT O 4000XLS Instruction M anual © 01.10.12 Step 5 P osition the operator r ear mount between post pivot br acket. Place a 1 / 2 ” bushing above the rear mount and a 3 / 16 ” bushing under the rear mount. Alig n the hole in rear mount, bushings and post pivot bracket and secur e with the 3 1 / 2 ” clevis pin and hair pin clip .
GT O 4000XLS Instruction M anual © 01.10.12 9 Gate in the CL OSED POSITION Pinch Area 2" minimum MAX 22" Clamp Level Operator Fence P ost Clevis Pin, Bushing, and Hairpin Clip Gate In Open .
10 GT O 4000XLS Instruction M anual © 01.10.12 Install Closed P osition Stop Plate The closed position stop plat e helps to stabilize the gat e leaf in the closed position.
GT O 4000XLS Instruction M anual © 01.10.12 11 Mount the C ontr ol Bo x and Receiv er Use mounting holes and screws provided to mount control box to a secure surface.
12 GT O 4000XLS Instruction M anual © 01.10.12 Step 1 Loosen sealing nut on strain r elief hub at bottom of c ontrol box. Insert power cable into contr ol box thr ough strain relief . Thread appro ximately 6” of the power cable into the control bo x and retighten sealing nut until the pow er cable locks into place .
GT O 4000XLS Instruction M anual © 01.10.12 13 IMPORT ANT : • Thetransf ormerisdesignedandintendedf orindooruse.Ifthetransf ormercanonlybe plugged into an outside electrical outlet, a weatherproof c over/housing (a vailable at local electrical supply stores) must be used.
14 GT O 4000XLS Instruction M anual © 01.10.12 Step 5 Strip the ends of the low voltage wir e and twist tightly . Attach these ends to the 18 V AC OR SOLAR terminals located on the POWER INPUTS terminal block. Be certain not to let the exposed wires touch each other! Inser t one transformer wire int o an 18 V AC OR SOLAR terminal.
GT O 4000XLS Instruction M anual © 01.10.12 15 RED wire to POSITIVE ( + ) terminal BLACK wire to NEGATIVE ( – ) terminal RED BLACK Step 2 IMPORT ANT: C onnec t the BLACK battery wire to the NEGA TIVE (–) batteryterminal.ConnecttheREDbatterywiretothePOSITIVE(+) terminal.
16 GT O 4000XLS Instruction M anual © 01.10.12 1 2 3 4 ON DIP ST A TUS LEARN RMT LEARN MAST LIMIT LEARN 2ND LIMIT S3 S4 S2 OFF SOFT ST ART OFF W ARNING OFF OPEN PULL 2ND OPEN DL Y .
GT O 4000XLS Instruction M anual © 01.10.12 17 Pr ogram Y our Personal T ransmitter Setting All GT O transmitters are set to a standard c ode at the factor y and are ready to oper ate your GT O gate operat or . F or your safety and security , we strongly r ecommend that you replac e the factor y setting with your own personal setting.
18 GT O 4000XLS Instruction M anual © 01.10.12 DIP S witches DIP Switch Settings (MODES) DIP Switch #1: Soft Start/Stop ON– Soft star t enabled (factor y preset). OFF– Soft star t disabled. T he Soft Star t/Stop featur e slowly star ts the gate as it begins t o open and slows the gat e as it comes to the closed position.
GT O 4000XLS Instruction M anual © 01.10.12 19 C onnec ting Ac cessories Input Connections • Allcontrolinputsaredry- contact,normallyopen,inputs.DONO Tapplyex ternalvoltagesour cesto these inputs.
20 GT O 4000XLS Instruction M anual © 01.10.12 GRN CO MC OM CYCLE CLOSE SAFETY SHADOW LOOP CLOSE EDGE OPEN EDGE EXIT OPEN BLK RECEIVER RED AL M ORG LU E BRN RED STER INPUTS BLK STER CABL E CO NTROL I.
GT O 4000XLS Instruction M anual © 01.10.12 21 P ush- T o - O pen Installation Inf ormation Swinging ga tes shall not open into public ac cess areas! A “ Push-to-Open ” gate opens out from the pr oper ty (operator arm extends to open the gate). A P ush- T o - Open installation requir es the purchase of a P ush- T o- Open Bracket [R4KPT O].
22 GT O 4000XLS Instruction M anual © 01.10.12 Set Con trol Board f or Push- T o -O pen Make sure the contr ol box po wer switch is OFF . Use a small screwdriv er to mov e the Number 3 DIP switch from the factor y setting (OFF / Pull- T o- Open) to ON for P ush- T o- Open.
GT O 4000XLS Instruction M anual © 01.10.12 23 If this operator will be used with gates that ar e mounted on masonry , brick, or rock (etc.) columns , read the following car efully before proceeding A. The simplest solution is to install the operat or in a push-to- open conguration.
24 GT O 4000XLS Instruction M anual © 01.10.12 T roubleshooting Guide If your gate operat or does not function properly after it is installed, use this guide befor e calling the GT O Ser vice Depar tment.
GT O 4000XLS Instruction M anual © 01.10.12 25 Generation 3 V isual F eedback SY MPT OM DIA GNOSIS CHECK: Status (clear)1 blink Cycle T erminal Shor ted •Disconnectthepushbutton,keypad,inter comkeypad ,or any other acc essor y wired to this t erminal.
26 GT O 4000XLS Instruction M anual © 01.10.12 If your GT O 4000XLS Gate Operator is not oper ating properly , please follow the st eps below: 1. First use the pr ocedures f ound in the T roubleshooting Guide (see page 24). 2. Use the 24/7 T roubleshooting Wizard a t http://suppor t.
GT O 4000XLS Instruction M anual © 01.10.12 27 A cc essories f or 4000XLS POWERING A C CESSORIES Low V oltage Wire [RB509] The 16 gauge, str anded, dual conductor low v oltage Wire is f or connecting the AC power edtransf ormer ,solarpanelorwiredaccessoriestothesy stem ’ scontrolboard .
28 GT O 4000XLS Instruction M anual © 01.10.12 Residential Wireless En tr y Interc om [F3100MBC] Designed for added security to your aut omated gate with the ability to “ speak to ” and “ screen ” visitors safely fr om inside your home . Ideal for securing gat e entrances while providing c ontrolled acc ess.
GT O 4000XLS Instruction M anual © 01.10.12 29 ADDITIONAL A C CESSORIES Photo Beams [R4222] Primary “through beam ” photo beam device . Pr ovides “non-contact ” entrapment protection. Pin L ock [FM345] Use as a substitute f or the clevis pin at the front moun t of the PRO-SW4000XLS to preven t theft of the operator .
3121 Har tseld Road • T allahassee, F lorida, USA 32303 (850) 575-0176 • F ax (850) 575-8912 W eb site w w w .gtoacc ess.com 24/7 T roubleshooting W izard: http://suppor t.
Een belangrijk punt na aankoop van elk apparaat GTO 12 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GTO 12 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GTO 12 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GTO 12 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GTO 12 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GTO 12 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GTO 12 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GTO 12 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.