Model AD1686B General Purpose Indoor/Outdoor Receiver Installation and Operating Instructions This manual describes the installation and operating procedures for the AD1686B Dual Channel Receiver. Receivers are designed as the remote control device for operation of a motorized pan and tilt unit and a motorized lens unit.
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
.
CONTENTS Page DESCRIPTION............................................................................... 1 FEA TURES ..................................................................................... 1 Pan/T ilt and Lens Control ...................
.
AD1686B DESCRIPTION and FEATURES DESCRIPTION The AD1686B Receiver is a 2-channel controller used with Matrix Switching Systems to control pan, tilt, zoom, focus, iris, and auxiliary functions at a camera site. This Receiver is classified as a dual-channel type since two independent control channels are supplied, Channel A and Channel B.
SETUP AD1686B 2 SETUP Pan/Tilt Output Voltage The Pan/Tilt output voltages of each channel can be independently set for either 24 VAC or line voltage (120VAC or 230VAC). Two slide switches, S4 and S5 (see Figure 1), control the output voltages for the channels.
Table 2 - S3 Configuration Select Receiver Configuration Switch S3 general description is listed below. This table is continued on page 4 to describe the switch settings in detail, with a list of individual switch position settings.
Table 2 - S3 Configuration Select (Continued from page 3) L = left ("off"); R = right ("on") SW1 - Channel B Type - The AD1686B can act as a dual camera receiver with no auxiliaries, or as a single camera receiver with a set of auxiliaries.
AD1686B SETUP 5 Table 3 - S1 Camera Number Switch Settings - Channel A L = left ("off"); R = right ("on") CAMERA Switch Position CAMERA Switch Position NUMBER 1 2 3 4 5 6 NUMBER 1 .
SETUP AD1686B 6 Table 4 - S2 Camera Number Switch Settings or Auxiliary Settings Channel B L = left ("off"); R = right ("on") CAMERA Switch Position CAMERA Switch Position NUMBER 1.
INSTALLATION This installation should be made by qualified service personnel and should conform to all local codes. Safeguards must be taken to avoid unintentional operation by employees and maintenance personnel working about the premises, by falling objects, by customers, by building vibration, and by similar causes.
CONNECTIONS Code Line Connections The AD Code Line connection to the Receiver is made with user-supplied, shielded 2-wire twisted pair, Belden 8760 or equivalent (for Plenum use Belden 88760 or equivalent).
AD1686B CONNECTIONS Pan/Tilt and Lens Connections The AD1686B Receiver connection to a Pan/Tilt and a motorized Lens is with a 12-pin connector. This connector, for Channel A, is located on the main PCB, to the right of the DIP switches S1 and S2, and is labeled J5 (see Figure 1, page 3).
CONNECTIONS AD1686B 10 Table 5 - Dual Pan/Tilt and Lens 12-pin Connector Pinout Channel A - J5 PIN No. FUNCTION Pan/Tilt PINOUT LENS PINOUT 01 Tilt Up _____________________ ____________________ 02 Til.
AD1686B CONNECTIONS Auxiliary Connections When the AD1686B Receiver is set for single camera operation with auxiliaries, connection of auxiliary equipment to Channel B is made to the 12-pin connector, labeled J4, located on the Receiver PCB. See Figure 1, page 3.
Pre-position (Preset) Connections The AD1686B Receiver connection to the Pan/Tilt and Lens pre-position servo unit is with a 9-pin connector labeled J2 (see Figure 1, page 3). For dual camera channel operation, a second 9-pin connector, labeled J3, is used for Channel B.
AD1686B CONNECTIONS 13 Table 7 - Pre-position Pan/Tilt and Lens 9-pin Connector Pinout Channel A - J2 PIN No. FUNCTION Pan/Tilt PINOUT LENS PINOUT 01 (+) REF _____________________ ____________________.
CONNECTIONS AD1686B Power Input Connections Refer to the instructions provided with the enclosure for suitable conduit connectors (when required), and mounting and caution information. Two type PG-16 liquid tight fittings are supplied for use with cord diameters from .
TYPICAL SYSTEM CONNECTIONS.
TYPICAL SYSTEM CONNECTIONS AD2150 Controller to AD1686B MAXIMUM DISTANCE between AD1686B and AD2150 is 5000 Ft, using shielded, 18 AWG cable AD2150 AD1686B BWS RS232 PORTS 123 KEYBOARDS 2345 CAMERAS A.
TYPICAL SYSTEM CONNECTIONS AD1996 Controller to AD2091 Code Generator, to AD1686B AD1686B AD2091 AD1996 ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF ABCDEF ON OFF B W S B W S B W S B W S B W S B W S B W .
TYPICAL SYSTEM CONNECTIONS AD1686B to AD1240P Pan/Tilt with Pre-position AD1686B 1240P PAN/TILT C-4 Code PWR F2 F1 S5 S4 24V 120V 24V 120V J2 J5 J3 J4 S3 8 1 OFF ON S1 6 1 S2 6 1 W S B J6 AD1240P 13-pin Connector, Pan/Tilt pins: 1. PAN/TILT COMMON 2. PAN RIGHT 3.
INDEX.
INDEX AD1686B Auto and Random Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Auxiliaries Configuration Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
SPECIFICATIONS Supply Voltage: AD1686B 120 VAC, 50/60 Hz AD1686B-X 230 VAC, 50 Hz Power: 30 W (standby) AD1686B: 1240 W maximum input @ 120 VAC AD1686B-X 1420 W maximum input @ 230 VAC Mounting: Surface Mount Size: 15.5" H x 12.8" W x 6.7" D (394 x 325 x 170 mm) Weight: 16 lbs.
Een belangrijk punt na aankoop van elk apparaat American Dynamics AD1686B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Dynamics AD1686B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Dynamics AD1686B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Dynamics AD1686B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Dynamics AD1686B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Dynamics AD1686B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Dynamics AD1686B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Dynamics AD1686B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.