Gebruiksaanwijzing /service van het product Pier-HVB-IPI van de fabrikant Hearth and Home Technologies
Ga naar pagina of 40
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 1 Models: Pier-HVB-IPI ST -HVB-IPI Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 3 Safety and W arning Information .................................................. 2 Service Parts List .....................................................................
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 4 Part number list on following page. Log Assembly Service Parts Diagram Service Parts Pier-HVB-IPI Beginning Manufacturing .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 5 Service Part List PIER-HVB-IPI Î I T EM DES CRI P TI O N S ERI AL # P ART NUM BER Log Set A s s em bly LOGS -MS B Y 1L o .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 6 Service Parts Diagram Service Parts ST -HVB-IPI Beginning Manufacturing Date: June 2003 Ending Manufacturing Date: ______ Part number list on following page.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 7 Service Part List ST -HVB-IPI I T EM DES CRI P TI O N S ERI AL # P ART NUM BER Log Set A s s em bly LOGS -MS B Y 1L o g 1 .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 8 I T EM DES CRI P TI O N S ERI AL # P ART NUM BER Pilo t A s s e mb ly N G 38 5-510A Y Pilo t A s s e mb ly LP 385-511 A Y .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 9 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 10 For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in who.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 11 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 12 Figure 1. Diagram of the PIER-HVB-IPI 42-5/8 (1082mm) Ø 8 (204mm) 12 (305mm) ELECTRICAL ACCE SS GA S LI NE ACCE SS 34-3/.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 13 Figure 2. Diagram of the ST -HVB-IPI 5-14 (133 mm ) 12 (306m m ) 1/2 (13mm) (4) 46-5/ 8 (1183mm) 42 (1067 mm ) 32-5/ 16 (.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 14 3 Inst alling the Fireplace Step 1. Locating the Fireplace The diagram below shows space and clearance require- ments for locating a fireplace within a room.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 15 Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Sides or Ends .......... 3 6 .................... 9 1 4 Floor . .. ..........................
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 16 PIER-HV -IPI ST -HV -IPI D B C A A C B E Framing should be constructed of 2 X 4 lumber or heavier . Model A B C D E PIER-HVB-IPI 42-1/8 42-1/2 23 35-3/4 48 ST -HVB-IPI 47-5/8 42-1/2 23 35-3/4 48 Figure 5.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 17 NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT . Figure 6. DVP-Series Direct V ent Component Specifications (5-inch inner pipe / 8-inch outer pipe) D V P 9 0 S T 12- 9/1 6 11 - 1 / 4 7-1 /4 1-1/4 T YP 1/2 TYP 8-9 /16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 18 Figure 7. V ent System Component s and T ermination Kits Step 3. Inst alling the V ent System A. V ent System Approvals These models are approved to use DVP series direct vent pipe components and terminations (see Figures 6 and 7).
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 19 Figure 8 NOTE: On vertical venting configurations you may want to install the flue re- strictor (385-128). See flue restrictor installation in- structions. Flue Restrictor Instructions 1.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 20 Figure 14. V enting with One 90° Elbow Figure 13. V enting with One 90° Elbow V H H V NA TURAL GAS - VENTING WITH ONE 90° ELBOW V (FT .) H (FT .) 1' MIN. (305mm) 3' MAX.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 21 Figure 15. V enting with T wo 90° Elbows H 1 H V V V 1 H NA TURAL GAS VENTING WITH TWO 90° ELBOWS V (FT .) H + H 1 (FT .) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 22 Figure 16. V enting with T wo 90° Elbows Figure 17. V enting with T wo 90° Elbows H 1 V H V H H 1 NA TURAL GAS VENTING WITH TWO 90° ELBOWS V (FT .) H + H 1 (FT .) 1' MIN.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 23 Figure 18. V enting with three 90° elbows H H 1 H 2 V H V H 1 V 1 NA TURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT .) H + H 1 + H 2 (FT .) 1' MIN. (305mm) 3' MAX.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 24 Figure 19. V enting with three 90° elbows V H H 1 V 1 V H H 1 V 1 NA TURAL GAS VENTING WITH THREE 90° ELBOWS V + V 1 (FT .) H + H 1 (FT .) 90 0 Elbow on top 2.5’ MAX. (64mm) 1' MIN.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 25 1. Att ach the First V ent Component to the Starting Collars T o attach the first vent component to the starting collars of the fireplace: • Slide the first vent section onto the unit and push in until they snap lock in position.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 26 4. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 27 Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previously cut and framed hole.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 28 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. V ent T ermination Minimum Clearances A = 1 2" ....................... clearances above grade, veran- da, porch, deck or balcony B = 1 2" .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 29 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 30 Step 4. Positioning, Leveling, and Securing the Fireplace • Place the fireplace into position. • Level the fireplace from side to side and from front to back. • Shim the fireplace with non-combustible material, such as sheet metal, as necessary .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 31 • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 32 IGNITION MODULE (3V) VA LV E LOW VOL TAGE PLUG-IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SP ARKER/ SENSOR REMOTE CONTROL.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 33 Wall Switch Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W .G . minimum wire and connect it to the fireplace ON/OFF switch pigtails.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 34 If the box is being wired to a wall mounted swi tch f or use with a fan (See Figure 37): • The power supply for the appliance must be brought into a switch box.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 35 Step 9. Finishing Figures 38 and 39 show the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 36 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 37 Placing the Ember Material Ember material is shipped with this gas fireplace. The bag labeled Glowing Ember (050-721) is standard glowing em- ber material. T o place the ember material: • Remove the wing nuts and glass clips or tension springs around the glass door .
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 38 Step 1 1. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: ! ! Step 12.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 39 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and.
Heat & Glo • PIER-HVB-IPI, ST -HVB-IPI • 2006-901 Rev . C • 12/07 40 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Hearth and Home Technologies Pier-HVB-IPI (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hearth and Home Technologies Pier-HVB-IPI heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hearth and Home Technologies Pier-HVB-IPI vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hearth and Home Technologies Pier-HVB-IPI leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hearth and Home Technologies Pier-HVB-IPI krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hearth and Home Technologies Pier-HVB-IPI bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hearth and Home Technologies Pier-HVB-IPI kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hearth and Home Technologies Pier-HVB-IPI . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.