Gebruiksaanwijzing /service van het product CFL-18LP-C van de fabrikant Heat & Glo
Ga naar pagina of 28
1 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODELS: NA TURAL GAS PROP ANE CFL-18NG-C CFL-18LP-C CFL-24NG-C CFL-24LP-C CFL-30NG-C CFL-30LP-C ST -CFL-24NG.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ D.
3 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 = Contains updated information. T able of Contents 1 Introduction A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 4 opening provided by the fi replace chimney damper to vent the fl ue products must not be less than 51 square inches (328 cm 2 ). The chimney damper MUST be fi xed in a man- ner to maintain the minimum permanent vent opening.
5 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODEL CFL-18-C MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 1/2 ” (750mm) REAR WIDTH : 19 1/2 ” (521mm) DEPTH.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 6 Figure 2. DAMPER CLAMP OPEN DAMPER These models contain complete gas-burner , grate(s), and log components needed. Use caution when handling logs to avoid damage.
7 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Figure 3. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI 7. T est fi re the unit after referring to the SAFETY INFOR- MA TION and LIGHTING INSTRUCTIONS found in Section 3 in this manual, or on the label plate assembly found on the gas-burner .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 8 • If a remote control is used, the receiver cannot be placed under the burner . If possible, place the receiver outside the combustion chamber . • If the receiver must be placed in the combustion chamber , the protective heat shield MUST be used.
9 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Upon completing the gas line connection, a small amount of air will be in the lines. When fi rst lighting the pilot light, it will take a few minutes for the lines to purge themselves of this air .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 10 Lighting Instructions (IPI) The IPI system must be operated with two D-cell batteries. 1. Turn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner.
11 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 12 A. Standing Pilot Ignition System 4 4 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
13 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) c. V alve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 14 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. a. Incorrect wiring.
15 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite.
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 16 Service Parts Diagram CFL-18NG-C, CFL-18LP-C A. Service Parts 5 5 Reference Materials Part number list on following page. Log Set Assembly 5 2 4 9 8 6 1 3 10 7 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov .
17 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-18NG-C, CFL-18LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 18 Service Parts Diagram Service Parts CFL-24NG-IPI, CFL-24LP-IPI Part number list on following page.
19 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 20 Service Parts Diagram Service Parts CFL-24NG-C, CFL-24LP-C Part number list on following page. Log Set Assembly 5 10 6 1 3 4 2 7 9 8 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov .
21 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-24NG-C, CFL-24LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 22 Service Parts Diagram Service Parts CFL-30NG-C, CFL-30LP-C Part number list on following page. Log Set Assembly 11 12 13 14 15 16 17 10 8 9 5 11 7 1 3 2 4 6 Beginning Manufacturing Date: Nov .
23 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-30NG-C, CFL-30LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 24 Service Parts Diagram Service Parts ST -CFL-24NG-B, ST -CFL-24LP-B Part number list on following page. Log Set Assembly 11 12 9 8 1 10 7 2 4 3 5 6 13 14 15 16 17 18 19 20 Beginning Manufacturing Date: Nov .
25 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 ST -CFL-24NG-B, ST -CFL-24LP-B Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 26 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnolo.
27 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface .
Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 28 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo CFL-18LP-C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo CFL-18LP-C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo CFL-18LP-C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo CFL-18LP-C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo CFL-18LP-C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo CFL-18LP-C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo CFL-18LP-C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo CFL-18LP-C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.