1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building.
2 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! SAFETY AND W ARNING INFORMA TION READ and UNDERST AND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty .
3 T ABLE OF CONTENTS Safety and W arning Information ......................... 2 Section 1: Approvals and Codes ...................... 4 Approval Listings and Codes ................................... 4 Appliance Certification ........................
4 Approval Listings and Codes Appliance Certification The Heat-N-Glo models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICA TION MODEL LABORA T OR Y TYPE ST ANDARD 6000TR & Underwriters V ented Gas ANSI Z21.
5 2 Getting S t arted Heat-N-Glo direct vent gas fireplaces are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. The information contained in this Installers Guide , unless noted otherwise, applies to all models and gas control systems.
6 Figure 1. Diagram of the 6000TR, 6000XL T -CDN and 6000XLS The Heat-N-Glo W arranty will be voided by , and Heat-N-Glo disclaims any responsibility for , the following actions: Installation of any damaged fireplace or vent system component. Modification of the fireplace or direct vent system.
7 Figure 2. Diagram of the 6000ARCH.
8 3 Inst alling the Fireplace Step 1 Locating the Fireplace The diagram below shows space and clearance requirements for locating a fireplace within a room.
9 A B C Framing should be constructed of 2 X 4 lumber or heavier . Model A B C D E 6000TR 42 38 1/4 22 42 26 1/4 6000XLS 42 38 1/ 4 2 2 N / A 26 1/ 4 6000XL T -CDN 42 3 8 1/4 22 42 N / A 6000ARCH 4 2*.
10 VENT SYSTEM TERMINA TION KITS VENT SYSTEM COMPONENTS Figure 5. V ent Components and T erminations Step 3 Inst alling the V ent System A. V ent System Approvals These models are approved to use D-series direct vent pipe components and terminations. Approved vent system components are labeled for identification.
11 D V -90D 65 / 3 2 57 / 8 73 / 8 D V -45D 67 / 1 6 11 1/16 61 / 2 85 / 8 81 / 2 51 / 1 6 8/ 1 2 11 5/8 85 / 8 11 15/16 D V -36D 35 3/4 47 3/4 D V -48D 5 3/4 8 3/4 11 3/4 D V -12D D V -09D D V -06D 6.
12 Figure 7. Straight Up V ertical V enting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) NOTE: Model 6000ARCH A 12-inch length of straight vent pipe MUST be the first vent component attached to the unit.
13 HORIZONT AL VENTING H Kit No. Max. Run DVK-01D DVK-01TRD 24" (610 mm) NOTE: Models 6000TR and 6000XLS are tested and approved to use 45° elbows in corner inst allations.
14 VENTING WITH ONE (1) 90° ELBOW V (FT .) H (FT .) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) H = 8' MAX. (2.4m) V+H = 40' MAX.
15 VENTING WITH ONE (1) 90° ELBOW V (F T . ) H ( F T .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H = 20' MAX. (6.2m) V + H = 40 MAX.
16 VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX.
17 VENTING WITH TWO (2) 90 o ELBOWS V (FT .) H + H 1 (FT .) 1' MIN. (305mm) 5 ´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m ) 3' MIN. (914mm) 15´ MAX. (4.65m ) 4' MIN. (1.22m) 20´ MAX. (6.2m ) V+H+H 1 = 40' MAX.(12.4m) H+H 1 = 20´ MAX.
18 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52 m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1 m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65 m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2 m) V+H+H 1 +H 2 = 40 ´ MAX.(12.4 m) H=8´MAX.
19 VENTING WITH THREE (3) 90° ELBOWS V (FT .) H (FT .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H 1 = 20' MAX.
20 Figure 15 For Model 6000TR B. Inst alling V ent Components For Model 6000TR After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly . V enting Out the Rear V ent Remove the installed rear seal cap from the rear starting collars by cutting the strap at each end.
21 W ARNING: ENSURE THA T THE FIBER- GLASS ROPE GASKET SUPPLIED WITH THE FIREPLACE SEALS BETWEEN THE FIRST VENT COMPONENT & THE OUTER FIREPLACE WRAP . 1. Attach the First V ent Component to the Starting Collars T o attach the first vent component to the starting collars of the fireplace: Apply a 3/8 inch (9.
22 2. Continue Adding V ent Component s T o continue adding vent components in accordance with the pre-planned vent system configuration: Ensure that each succeeding vent component is securely fitted and locked into the preceding com- ponent in the vent system.
23 For V ertical Runs - The vent system must be supported every eight (8) feet (2.4 m) above the fireplace flue outlet by wall brackets. T o install support brackets for vertical runs: Attach wall brackets to the vent pipe and secure the wall bracket to the framing members with nails or screws.
24 TRIM HEA T SHIELD IF TOO LONG , ADD TO SHIELD IF TOO SHORT EXTERIOR FIRESTOP INTERIOR FIRESTOP HEA T SHIELD Figure 20. 12" x 12" Hole and V ent Pipe 2. Position the firestops. 3. Place the heat shield to the top. 4. Continue the vent run.
25 Drill a hole or drive a nail through this centerpoint. Check the floor above for any obstructions, such as wiring or plumbing runs. Reposition the fireplace and vent system, if neces- sary , to accommodate the ceiling joists and/or obstructions.
26 JOIST CEILING FIRESTOP CEILING NAILS (4 REQUIRED) ! If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole. This shows an attic installation. 1. Keep insulation away from the vent pipe at least 1 inch (25 mm).
27 For round cap termination: 1. Secure the 8-5/8 inch (219 mm) pipe, using the exterior pipelock hole on the round flange of the wall firestop. For trapezoidal termination: 1. Screw the cap to the exterior wall through the flanges in the cap. 2. Seal the joint be- tween the pipe and the exterior firestop.
28 V =VENT TERMINAL X =AIR SUPPL Y INLET =AREA WHERE TERMINAL IS NOT PERMITTED A = 12" clearances above grade, veranda, porch, deck or balcony B = 1 2" clearances to window or door that may be opened C = 9" (U.
29 ! For V ertical T erminations - T o locate the vent and install the vent sections: Locate and mark the vent centerpoint on the under- side of the roof, and drive a nail through the centerpoint. Make the outline of the roof hole around the centerpoint nail.
30 TERMINA TION CAP T o seal the roof hole, and to divert rain and snow from the vent system: Attach a flashing to the roof using nails, and use a non-hardening mastic around the edges of the flashing base where it meets the roof. Attach a storm collar over the flashing joint to form a water-tight seal.
31 The diagram below shows how to properly position, level, and secure the fireplace. 1. Place the fireplace into position. 2. Level the fireplace from side to side and from front to back. 3. Shim the fireplace with non-combus- tible material, such as sheet metal, as necessary .
32 ST ANDING PILOT NOTE: FLAMES TOO CLOSE TO THE CERAMIC INSULA TORS CAN CAUSE NUISANCE LOCKOUTS AND ELECTRODE F AILURE. DSI IGNITION Figure 29. Gas Controls Systems Step 6 The Gas Supply Line NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes .
33 At the gas line access hole, use insulation to re- pack the space around the gas pipe. Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal be- tween the pipe and the outer casing. The gas line should be installed by a qualified service technician.
34 NOTE: 6000XL T -CDN DOES NOT HA VE A LIMIT SWITCH. ! ! Figure 31. Standing Pilot Ignition Wiring Diagram Step 8 Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. Caution: Disconnect remote controls if you are absent for extended time periods.
35 Figure 32. Fan Wiring Diagram For Direct Spark Ignition (DSI) Wiring Appliance Requirements This appliance requires that 1 10-120 V AC be wired to the factory installed junction box.
36 Figure 33. Direct Spark Ignition (DSI) Wiring Diagram Step 9 Finishing The following diagram shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
37 CAUTION IF JOINTS BETWEEN THE FINISHED W ALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F . MINIMUM SEALANT MA TERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONL Y NON- COMBUSTIBLE MA TERIAL (USING 300° F . MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS F ACING TO THE FIREPLACE SURROUND.
38 Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the installation instructions that accompany the logs. Save the log instructions with this manual.
39 1. Lift the trim door up and out of the unit. EYE BOL T LA TCH BRACKET GLASS DOOR Figure 38. Placement of the Ember Material CAUTION IT IS STRONGL Y RECOMMENDED THA T TRIM DOORS WITH OPTIONAL MESH SCREENS BE INST ALLED ON PROP ANE MODELS. Figure 36.
40 Before lighting the fireplace, be sure to do the following: Remove all paperwork and documents from the fireplace. Review safety warnings and cautions Read the Safety and Warning Information section at the beginning of this Installers Guide .
41 This model is equipped with a baffle which will allow you to control usable heat output. The baffle control lever is located at the lower left corner of the unit behind the lower grille. See Figure 39. FOR MORE HEA T : Pull the baf fle lever forward and down.
42 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check-up at the beginning of each heating season.
43 ST ANDING PILOT Figure 41. Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADYNOT LIFTING OR FLOA TING . Figure 42. Pilot/Ignitor Flame Patterns DSI IGNITION NOTE: FLAMES TOO CLOSE TO THE CERAMIC INSULA TORS CAN CAUSE NUISANCE LOCKOUTS AND ELECTRODE F AILURE.
44 PAR T P A RT DESCRIPT I O N PAR T N U MB E R V al v e LP SRV60–523 V a lv e NG SRV60–522 Pi ez o I gn i tor SRV60-513 T h er mopil e SR V60– 512 T h er mo cou pl e SR V446- 51 1 Pi lot O ri f.
45 PAR T P A RT DESCRI PTI O N P A RT NUM BER Pi ez o I gn i to r SR V60-513 T h erm opi le SRV60-512 The r m o c o up l e S R V 5 7 1 - 5 11 V al v e LP SR V571-501 V al v e N G SR V571- 500 Bu rn er.
46 PAR T P A RT DESCRI PT IO N PAR T N U MB E R DSI V al v e SR V476–500 DSI M odu le SR V501–592 Electrode SR V501-591 DSI Ignition Only PAR T P A RT DESCRI PT I O N P A RT NUM BER T r im Door DF.
47 PAR T P A RT DESCRI PTI O N P A RT NUM BER H i gh T emper atu r e Li mit Sw i tch SR V92–531 Bu rn er N G SR V 446-176A Bu rn er LP SR V 446-175A B u r n e r O r if ic e 6000T R N G R ear V en ti.
48 A CCESSO R Y P A RT DESC RI PTI ON PAR T N U M B E R Fan Kit G FK-16 0A R em ot e Con t ro l Kit R C-S MAR T SM AR T - ST A T RC - MLT W al l Sw itc h Kit - Off Whi te WS K -2 1 - W h it e W SK- 21.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle 6000ARCH (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle 6000ARCH heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle 6000ARCH vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle 6000ARCH leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle 6000ARCH krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle 6000ARCH bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle 6000ARCH kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle 6000ARCH . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.