Gebruiksaanwijzing /service van het product 8000TV-OAK-IPI van de fabrikant Heat & Glo LifeStyle
Ga naar pagina of 46
1 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Models: 8000TV -OAK 8000TV -OAK-IPI 8000TVLP-OAKIPI In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fi tter; • a CO detector shall be installed in the room where the appliance is installed.
2 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Congratulations Listing Label Information/Location Model Name: _______________________________________.
3 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Î = Contains updated information. T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . .
4 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 MODELS: 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: B-Vent Decorative STANDARD: ANSI Z21.50-2002 • CGA2.
5 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 E. Non-Combustible Materials Speci fi cation Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
6 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Design and Installation Considerations Heat & Glo B-type vent gas appliances are designed to operate with all exhaust gases expelled to the outside of the building, and combustion air pulled from the room.
7 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Figure 2.
8 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 D. Inspect Appliance and Components C. T ools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available.
9 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 AB C D E F G Inches 55-7/8 1/2 79 49 Min. 1 37-3/8 22 Millimeters 1419 13 2007 1245 25 949 559 Figure 3.
10 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 CLEARANCES TO COMBUSTIBLES AB C D E F G H I J Rough Opening (V ent Pipe) Rough Opening (Height) Rough.
11 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 D. Mantel Projections 1/2 INCH (13 mm) 32 IN. (813 mm) TOP OF HOOD 12 IN. (305 mm) NON-COMBUSTIBLE MA TERIAL ONL Y 13 IN. (330 mm) CEILING TOP FRONT EDGE OF FIREPLACE Note: Clearance from opening to perpendicular wall.
12 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ..................................
13 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 MET AL PLUMBER’S STRAP 9 FEET MINIMUM VENT SUPPORTS ARE PER VENT MANUF ACTURER’S SPECIFICA TIONS MINIMUM CLEARANCES ARE PER VENT MANUF ACTURER’S SPECIFICA TIONS MET AL PLUMBERS' STRAP MAXIMUM HORIZONTAL RUN IS 50% OF VERTICAL.
14 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Fire Risk. Explosion Risk. Insulation and other combustibles must not infringe on clearances. • AL WA YS maintain speci fi ed clearances around venting and fi restop systems.
15 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Note: This product MUST terminate vertically . Follow vent pipe manufacturer ’s instructions for all clear- ances around pipe. B. V ertical Penetration Framing Use B-vent manufacturer ’s fi restops to provide adequate clearances.
16 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Installing Outside Air Kit Damper Assembly Asphyxiation Risk. Fire Risk. Do NOT draw outside combustion air from: • W all, fl oor or ceiling cavity .
17 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Figure 7.3 Proper Positioning, Leveling and Securing of a Appliance NAILING T ABS (BOTH SIDES) Fire Risk. • AL WA YS maintain speci fi ed clearances around the appliance.
18 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Assembly of V ent Sections This appliance requires a 6-inch B-vent double-wall pipe. Follow the pipe manufacturer ’ s installation guidelines when installing the unit.
19 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Note: Have the gas supply line installe d in acco rdance w i t h l o c a l b u i l d i n g c o d e s , i f a n y . I f n o t , f o l l o w A N S I 223. 1 .
20 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury .
21 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 • This appliance MUST be used with a wall switch or a remote control. • This unit is not for use with thermostats. • Keep wire lengths short as possible by removing any excess wire length.
22 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 C. Intelli fi re Ignition System Wiring This appliance requires a 1 10 V AC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.
23 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 D. Standing Pilot Ignition System Wiring This s tanding pilot ignition system wiring does not require a 110 VAC supply to operate. Figure 10.3 Standing Pilot Ignition Wiring Diagram Figure 10.
24 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 If the box is being wired from the appliance: • Remove the screw attaching the junction box to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.
25 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Fire Risk Explosion Risk • Facing and/or finishing materials must never overhang into the glass opening. • Overhanging materials may ignite. • May interfere with proper operation of glass assembly .
26 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Ember material is shipped with this gas appliance. T o place the ember material: • When placing Glowing Embers ® onto the burner care should be taken so that the ports are not covered.
27 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Log Assembly: LOGS-8OAK F . Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions.
28 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 STEP 5: (SR V2057-723): Mate the top of log 4 with the right metal tab on log 3. The bottom of log 4 should touch the inside face of the right grate tine.
29 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 H. Screen Mesh The screen mesh is a protective barrier and must be at- tached. I. Grilles and T rim Install optional marble and brass trim surround kits as de- sired.
30 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Before operating this appliance have a qualified technician: • Remove all shipping materials from inside and/or underneath the fi rebox. • Review proper placement of logs, rockwool, lava rock, and vermiculite.
31 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 C. Lighting Appliance 1. T urn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner .
32 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position.
33 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
34 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 A. Standing Pilot Ignition System 1 4 14 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
35 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position.
36 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 B. Intelli fi re Ignition System Sympton Possible Cause Corrective Action 1.
37 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3. (Continued) Pilot lights but continues to spark, and main burner will not ignite.
38 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 1 5 15 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and mainten.
39 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present.
40 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 1 6 16 R eference Materials ELECTRICAL ACCESS A B C D E F G I GAS LINE ACCESS J K L M O P Q R H N A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
41 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Service Parts Service Parts Diagram 8000TV-OAK, 8000TV-OAK-IPI Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ 8 9 10 11 12 13 7 Log Set Assembly Part number list on following page.
42 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 IMPORT ANT : THIS IS DA TED INFORMA TION, When requesting service or replacement parts for your appliance please provide model number and serial number .
43 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Service Parts V alve Assembly Parts List 8000TV-OAK-IPI Beginning Manufacturing Date: Feb.
44 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Service Parts V alve Assembly Parts List 8000TV -OAK Beginning Manufacturing Date: Feb.
45 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 © 2007 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY HEA T & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 C. Limited Lifetime W arranty BASIC ONE-YEAR W ARRANTY .
46 Heat & Glo • 8000TV -OAK, 8000TV -OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev . L • 08/08 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle 8000TV-OAK-IPI (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle 8000TV-OAK-IPI heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle 8000TV-OAK-IPI vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle 8000TV-OAK-IPI leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle 8000TV-OAK-IPI krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle 8000TV-OAK-IPI bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle 8000TV-OAK-IPI kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle 8000TV-OAK-IPI . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.