Heat-N-Glo Fireplace Model: A T -ZC Patents Pending Installers Guide W ARNING: IMPROPER INST ALLA TION, ADJUSTMENT , AL TERA TION, SER VICE OR MAINTENANCE CAN CAUSE INJUR Y OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSIST ANCE OR ADDITIONAL INFORMA TION CONSUL T A QUALIFIED INST ALLER, SER VICE AGENCY , OR THE GAS SUPPLIER.
i SAFETY AND W ARNING INFORMA TION READ and UNDERST AND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty . Prior to the first firing of the fireplace, READ the Using Y our Fireplace section of the Owners Guide .
ii Safety and W arning Information .................... i Section 1: Approvals and Codes ................ 1 Approval Listings and Codes .................................. 1 Appliance Certification ............................................ 1 Installation Codes .
1 Approval Listings and Codes Appliance Certification The Heat-N-Glo models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICA TION MODEL LABORA TO R Y TYPE S T ANDARD A T -ZC Underwriters Direct V ent ANSI Z21.
2 2 Getting S t arted Introducing the Heat-N-Glo Gas Appliances Heat-N-Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
3 VENTING AND INST ALLA TION 1. Heat -N-Glo gas inserts are designed for recessed installations into solid fuel Masonry or Factory Built Non Combustible fireplaces that have been installed in accordance with the National, Provincial, S tate and local building codes.
4 When planning a fireplace insert installation, its necessary to determine: The vent system configuration to be used. Gas supply piping. Whether optional accessoriesdevices such as a wall switch, or remote controlare desired. Figure 1.
5 V ent System Installation Precautions Before starting installation of vent kits, the installer should read these instructions and the V ent Kit Instructions to ensure that a proper vent installation is completed. Consult your local Building Codes before beginning the Installation.
6 A vertical vent termination system installed on this model will include one (1) length of 3-inch flexible vent pipe for the combustion air , one (1) pipe-to-cap adaptor , and one (1) SLK-991DA or SLK-980D V ertical termination Cap. NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible- vent pipe.
7 TO A VOID DOWNDRAFTS AND/OR COLD AIR PROBLEMS, IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINA TION CAP AND THE TOP OF THE SOLID-FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP HAS BEEN INST ALLED. WHEN USING THE LINK-DV4-30 VENT SYSTEM, IT IS REQUIRED TO SEAL AROUND THE FLEXIBLE VENT PIPES IN THE DAMPER AREA.
8 Figure 3. W ARNING THE EXHAUST PIPE MUST ONL Y BE CONNECTED TO THE EXHAUST ST ARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINA TION CAP . THE INLET AIR PIPE MUST ONL Y BE CONNECTED TO THE INLET A IR COLLAR OF THE UNIT AND EITHER A T T ACHED TO THE INLET A IR COLLAR OF THE TERMINA TION CAP OR TERMINA TED IN THE CHIMNEY .
9 Figure 4 Figure 5 EXHAUST ST ARTING COLLAR INLET AIR ST ARTING COLLAR.
10 1. Place the insert into position. 2. Level the insert from side to side and from front to back. If necessary use the legs included in the manual bag. Screw the legs into the nuts installed in the bottom rear of the insert. T urn legs in until insert is level.
11 Step 4 The Gas Supply Line NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes . NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air .
12 Step 5 Gas Pressure Requirement s Pressure requirements for Heat-N-Glo gas appliances are shown in the table below . Pressure Natural Gas Propane Mini mum 5.0 inches 1 1.0 inches Inlet Pressure w .c. w .c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w.
13 Optional Accessories Optional fan and remote control kits require that 1 10- 120 V AC be supplied to the factory installed junction box. Run the cord out the notch in the surround and plug into a convenient outlet. Remote W all Switch Position the remote wall switch in the desired position on a wall.
14 NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED , IT MUST BE REPLACED WITH TYPE 105 DEGREE C RA TED WIRE. NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED , IT MUST BE REPLACED WITH TYPE 105 DEGREE C RA TED WIRE.
15 GLASS DOOR Remove the glass door from the unit. Cover the top of the burner with a single layer of ember material. Then sprinkle GE-93 on top of the burner . Save the remaining ember materials for use during fireplace servicing. Replace the glass door .
16 Combustible materials MUST NEVER overlap onto the front face. Step 8 Inst alling T rim Surrounds NOTE: REMOVE FRONT TRIM DOOR AND GLASS DOOR ASSEMBLIES FROM THE INSERT BEFORE SURROUND INST ALLA TION. 1. Find the coiled low voltage wires and ON/OFF switch attached to outer right side of the insert.
17 3. Run the low voltage lead wires up the back of the right side of the surround and secure them with the three wire ties found there. Re-connect the low voltage wires to the short wires of the ON/OFF switch. 4. Position surround on face of unit by hooking surround behind top ledge on unit.
18 Step 9 Before Lighting the Appliance Before lighting the appliance, be sure to do the following: Review safety warnings and cautions Read the Safety and W arning Information section at the beginning of this Installers Guide . Double-check for gas leaks Before lighting the appliance, double-check the unit for possible gas leaks.
19 4 Maint aining and Servicing Y our Appliance Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check-up at the beginning of each heating season.
20 ST ANDING PILOT 3/8" (10 mm) Figure 14. Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADYNOT LIFTING OR FLOA TING . Figure 15. Pilot/Ignitor Flame Patterns.
21 PAR T P A RT DESCRIPTI O N PAR T N U M B E R V al v e LP SRV60–523 V alv e NG SRV60–522 Pi ez o I gn i tor SRV418-513 T h erm opi le SR V 60–512 T h er m oco u pl e SR V446- 51 1 Pi lot O rif.
22 PAR T P A RT DESCRIPTI O N P A RT NUM BE R Bu r n er SR V485-275A Bu r n er O ri fi ce N G SR V60-800 Bu r n er O r i fi ce LP SR V60-801 R otory Sw i tch SR V436-525A G l ass Door Assem b ly G L A.
23 St anding Pilot (Cont.) Accessories A CCESSO R Y P A RT DESCR I PTI O N P A RT NUM BER R em ot e Con t ro l K i t R CH- 09A RC - S MA RT SM AR T -ST A T RC -MLT W al l Sw it c h Kit - Off Wh i te W.
24 Accessories - (Continued) ZC-3624-3 DF-ZC-Carch T rim Door ZC-3627-4 DF-ZC T rim Door ZC-4028-3 ZC-3627-3.
25 DF-ZC32- T rim Door DF-ZC36- T rim Door DF-ZC32-Carch T rim Door DF-ZC36- Carch Door Accessories - (Continued).
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle AT-ZC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle AT-ZC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle AT-ZC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle AT-ZC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle AT-ZC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle AT-ZC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle AT-ZC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle AT-ZC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.