Gebruiksaanwijzing /service van het product EXCLAIM-36T-C van de fabrikant Heat & Glo LifeStyle
Ga naar pagina of 48
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 1 Owner ’ s Manual Installation and Operation Models: EXCLAIM-36H-C EXCLAIM-36T -C Woodburning Fireplace DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 2 Read this manual before installing or operating this fi replace. Please retain this owner ’ s manual for future reference. Congratulations on selecting a Heat & Glo wood burning fi re- place.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 3 T able of Contents 1 Listing and Code Approvals 4 A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Getting Started 5 A. Design and Installation Considerations .
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 4 1 1 Listing and Code Appro v als A. Appliance Certi fi cation This fi replace system has been tested and listed in accor- dance with UL 127 and ULC-S610 standards by Underwrit- ers Laboratories Inc.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 5 2 2 Get ting Star ted A. Design and Installation Considerations Draft is the pressure difference needed to vent fi replaces successfully . Considerations for successful draft include: • Preventing negative pressure • Location of fi replace and chimney B.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 6 Location of the fi replace and chimney will affect performance. As shown in Figure 2.1 the chimney should: • Be installed through the warm airspace enclosed by the building envelope.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 7 C. T ypical Fireplace System The Heat & Glo fi replace system consists of the following: • Fireplace/integral.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 8 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 9 3 3 F raming and Clearances A. Selecting Fireplace Location Several options are available to you when choosing a loca- tion for your fi replace. This fi replace may be used as a room divider , installed along a wall, across a corner or used in an exterior chase.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 10 B. Clearances 0 in. to floor 1 in. (25 mm) to side of appliance (except at nailing flanges where it is 1/2 in. (13 mm)) 1 in. (25 mm) to b ack of appliance Attic Insulation Shield Ceiling Firestop (ceiling) (roof) (attic) (ceiling) 2 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 11 C. Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum of 12 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 12 E. Construct the Chase A chase is a vertical boxlike structure built to enclose the fi replace and/or its vent system. V ertical chimneys that run on the outside of a building may be, but are not required to be, installed inside a chase.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 13 Risk of Smoke Spillage Outside air inlet must be located to prevent blockage from: • Leaves • Snow/ice • Other debris Blockage may cause combustion air starvation.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 14 Handle up - open Handle down - closed Figure 4.4 Locating the Outside Air Control Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 15 B. Secure the Fireplace • Position the Fireplace This fi replace may be placed on either a combustible or noncombustible continuous fl at surface. Follow the in- structions for framing in Section 3.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 16 NOTE: • Chimney performance may vary . • Trees, buildings, roof lines and wind conditions af fect performance. • Chimney height may need adjustment if smoking or overdraft occurs.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 17 A. Chimney Requirements V ertical distances are measured from the base of the fi re- place as shown in Figure 5.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 18 B. Using Offsets/Returns T o bypass any overhead obstructions, the chimney may be offset using a 30-deg (SL430) of fset/return. An offset and return may be attached together or a chimney section(s) may be used between an offset and return.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 19 C. Assemble the Chimney Sections Attach either a straight chimney section or an offset to the top of the fi replace (depending on your installation require- ment).
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 20 E. Install the Attic Insulation Shield An insulation shield must be installed when there is a pos- sibility of insulation coming into contact with the factory built chimney system.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 21 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 22 T ermination Cap Storm Collar Slope Downward T urn-down Drip Edge Chase (Chimney) 2 in. (51 mm) Collar on Chase T op Caulk .018 (26 ga) min. Galvanized Chase T op Figure 6.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 23 2 in. (51 mm) min. 4-1/2 in. (1 14 mm) max. 1-1/2 in. (38 mm) min.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 24 A. Gas Log/Lighter Provisions A certi fi ed gas log lighter or decorative gas log set can be installed in this fi replace. • Maximum input is 100,000 BTU/hr . • Decorative gas appliance must be certi fi ed to ANSI Z21.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 25 8 8 Fin i shi ng A. Hearth Extension A hearth extension must be installed with all fi replaces to protect the combustible fl oor in front of the fi replace from both radiant heat and sparks.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 26 3 0 in. (762 mm) min . 12 in. (305 mm) Min. 12 in. (305 mm) Min. Figure 8.4 Raised Hearth Extension Figure 8.5 Flush Hearth Extension 12 in. (305 mm) Min. 12 in. (305 mm) Min.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 27 B. Finishing Material • Combustible Material Material which is made of or surfaced with wood, compressed paper , plant fi bers, plastics, or any material capable of igniting and burning, whether fl ame proofed or not, plastered or not plastered.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 28 HOT! DO NOT TOUCH. SEVERE BURNS MA Y RESUL T . CLOTHING IGNITION MA Y RESUL T . • Keep children away . • CAREFULL Y SUPERVISE children in same room as fi replace.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 29 D. Flue Damper The fl ue damper must be in full open position, and is oper- ated by moving the handle up toward the top of the fi replace. Before lighting the fi re, verify this by looking up from the in- side of the fi replace.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 30 G. Grate The factory installed integral grate must be used to hold the logs from falling out of an open fi replace and to allow air to pass between the burning logs.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 31 I. Starting a Fire Check the fl ue damper to be certain it is in the full open po- sition. Place crumpled or twisted paper under the fi replace grate. Loosely arrange kindling or small pieces of wood to form a layer above the paper .
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 32 1 0 10 T roubleshooting Another appliance in home also exhausting air (furnace, fan, dryer , etc.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 33 Diagnostic Questions Possible Causes of Condition Solutions Is the damper open? • No draft Open damper . Is there enough paper/starter? • Insuf fi cient heat to ignite kindling Use more paper/starter .
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 34 Diagnostic Questions Possible Causes of Condition Solutions Do you have glass doors? • Need to slow air intake Add glass doors. What is the condition of the wood? • Extremely dry wood Mix in less seasoned wood after fi re established.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 35 A. Disposal of Ashes Ashes should be placed in a metal container with a tight- fi t- ting lid. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustible materials, pending fi nal disposal.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 36 Fire Risk • Do not use chimney cleaners or fl ame colorants in your fi replace. Will corrode chimney . W ARNING D. Maintenance T ask List Asphyxiation Risk Fire Risk Annual inspection by qualified technician recommended.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 37 1 2 12 Referen ce Materials A. Fireplace Dimensions 49-5/8 in. (1260 mm) 28-1/2 in. (724 mm) 43-1/8 in. (1095 mm) 59-1/4 in. (1505 mm) 7-5/8 in. (194 mm) 36 in. (914 mm) 71-3/4 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 38 B. Fireplace Components GR37 Integral Grate Bi-fold Glass Doors Herringbone Pattern Refractory T raditional Brick Pattern Refractory 20 in. (508 mm) 66 in. (1676 mm) 1/2 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 39 C. Chimney Components The following pictures show only those chimney components which may be safely used with this fi replace. 13 in. (330 mm) 14 in. (356 mm) 14 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 40 SL430 - Offset/Return A B 17 in. (432 mm) Ceiling fi restop 24 in. (610 mm) 17 in. (432 mm) AS10 - Straight Attic Insulation Shield 2 in. (51 mm) 13 in. (330 mm) JB577 - Chimney Joint Band 13 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 41 TR444 - Round T ermination Cap TR442 - Round T elescoping T ermination Cap ST475 - Square T ermination Cap 72 in. (1829 mm) 36 in. (914 mm) 2 in. (51 mm) 13-3/8 in. (340 mm) CT56 - Chase T op A B C D Decorative Shroud LDS33/LDS46 15-3/4 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 42 This page intentionally left blank..
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 43 Woodburning T ermination Cap Shroud TS345 / 445 (T op V ent) TR342 / 344 TR442 / 444 TR342 / 344 TV TR442 / 444 TV (with TR-TVK installed) TR1 1 / 1 1T TR1 1 / 1 1T TV (with TR-TVK installed) OPEN TOP with solid sides and 3 in.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 44 D. Service Parts Exploded Parts Diagram 36 in. Woodburning Fireplace Service Parts EXCLAIM-36-C SERIES Beginning Ma.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 45 Service Parts List 36 in. Woodburning Fireplace Service Parts EXCLAIM-36-C SERIES Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active # Description of Part EXCLAIM-36T -C EXCLAIM-36H-C Qty .
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 46 This page intentionally left blank..
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 47 E. Limited W arranty W ARRANTY FOR HEA T & GLO FIREPLACES The limited warranty will not become effective until you have mailed the completed warranty card to: Hearth & Home T echnologies Inc.
Heat & Glo • EXCLAIM-36C Woodburning Fireplace • 4013-093 Rev G • 08/06 48 Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer , please call 1-888-427-3973. – NOTES – F .
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle EXCLAIM-36T-C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle EXCLAIM-36T-C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle EXCLAIM-36T-C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle EXCLAIM-36T-C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle EXCLAIM-36T-C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle EXCLAIM-36T-C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle EXCLAIM-36T-C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle EXCLAIM-36T-C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.