Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 1 Model(s): LUX60 Owner ’ s Manual Installation and Operation Installation and service of this appliance should be performed by qualified personnel.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ S.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 4 = Contains updated information. 17 Reference Materials A. Appliance Dimension Diagram 54 B.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++7.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 7 C. BTU Speci fi cations MODELS: LUX60 LABORA TOR Y : Underwriters Laboratories, Inc. (UL) TYPE: V ented Gas Fireplace Heater STANDARD: ANSI Z21.88b-2008 • CSA 2.33b-2008 E. Noncombustible Materials Speci fi cation Material which will not ignite and burn.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwell.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 9 Fixed Glass Assembly Section 2.F . “L” Pieces-Facing Section 3.A. Hearth (not required) Noncombustible Zone Clear Space Section 2.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 10 Clear Space 3 ft (0.91 m) in front of appliance C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 1 1 Matching Security Codes It may be necessary to program the control module to the security code of the remote upon initial use, if batteries are replaced, or if a replacement control module is pur- chased from your dealer .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 12 I. IntelliFire Ignition System (IPI) Lighting Instructions • For normal use, activate/deactivate your fi replace with the remote control. • If your fi replace must be deactivated for serviced or an extended period of time, follow the instructions below .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 13 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 15 Doors, Surrounds, Fronts Frequency: Annually By: Homeowner T ools needed : Protective gloves, stable work surface • Assess condition of screen and replace as necessary . • Inspect for scratches, dents or other damage and repair as necessary .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 16 Control Compartment and Firebox T op Frequency: Annually By: Quali fi ed Service T echnician T ools needed : Protective gloves, vacuum cleaner , dust cloths • V acuum and wipe out dust, cobwebs, debris or pet hair .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 17 Light Glass Replacement/Cleaning Frequency: Annually By: Quali fi ed Service T echnician T ools needed : Protective gloves • Disconnect power to fi replace. • Remove the “L” plates and inner surround frame (see surround install).
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 18 Clean Porcelain Panels Frequency: As needed By: Quali fi ed Service T echnician T ools needed : Protective gloves, phillips screwdriver • Disconnect power to fi replace. • Remove the “L” plates and inner surround frame (see surround install).
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 19 Remove 4 Screws Figure 3.12 Remove Pilot Shield Figure 3.10 Remove Decorative Steel Log Assembly Figure 3.1 1 Remove Center Burner T ube • Remove decorative steel log assembly by removing 3 screws, lifting up and out (Figure 3.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 20 V ertical T ermination Cap Section 10 Storm Collar Section 10 V ent pipe penetrates roof, preverably without affecting roof rafters. Section 8 Attic insulation shield (not shown) must be used here to keep insulation away from vent pipe if attic is insulated.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 21 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 22 5 5 F raming and Clearances A. Select Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 23 C. Construct the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 24 Combustible flooring may be installed next to the front of the appliance. 86 in. 2184 mm) 6 in. (152 mm) minimum 52 in. (1321 mm) Drywall 1-1/2 in. (38 mm) 0 in. 1-1/2 in. (38 mm) 0 in. 10 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 25 A. V ent T ermination Minimum Clearances Figure 6.1 Minimum Height From Roof T o Lowest Discharge Opening Horizontal overhang 12 X 20 in. (508 mm) Lowest Discharge Opening T ermination Cap Roof Pitch is X / 12 V ertical wall H (min.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 26 Dimension Descriptions A Clearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm) minimum. * B Clearance to window or door that may be opened – 10,000 BTUs or less, 6 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 27 Horizontal V ertical 8-1/2 in. 8-1/2 in. 12 in. On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 28 H 1 V 1 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally .
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 29 4 ft min. (1.22 m) 17 ft max. (5.18 m) 3 ft min. (.91 m) 1. T op V ent - Horizontal T ermination - (continued) Figure 7.4 T wo 45° Elbows replacing One 90° Elbow Figure 7.5 Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 H 1 V 2 H 2 3 ft (.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 30 2. T op V ent - V ertical T ermination No Elbow Figure 7.7 Figure 7.8 T wo Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 18 ft (5.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 31 No combustible framing to be located within shaded area. 1-1/2 in. (13 mm) minimum to perpendicular wall. WAL L Cement Board 3 in. (76 mm) Steel Stud Assembly Air space clearance to bottom and sides of horizontal pipe must be at least 1 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 32 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and at- tics. • Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 33 Bend all tabs inward 90° to maintain clearance and prevent insulation from falling inside Insert 3 screws Bend 4 tabs inward 90° to maintain clearance D. Install Attic Insulation Shield W ARNING! Fire Risk.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 34 6 in. (152 mm) minimum Steel Stud Assembly Secure with screws Required manual gas cock location within 72 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 35 Lances 1 0 10 Install V ent Pipe A. Assemble V ent Sections Attach Pipe to the Firebox Assembly Note: The end of the pipe secti ons with the lanced t abs will face towards the applianc e.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 36 B. Assemble Slip Sections W ARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in. (38 mm). Secure slip sections with two screws which must not exceed 1/2 in. (13 mm) in length.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 37 D. Disassemble V ent Sections • Rotate either section (see Figure 10.9) so the seams on both pipe sections are aligned as shown in Figure 10.10. • Pull carefully to separate the pieces of pipe.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 38 F . Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp. • Connect the halves of the storm collar with two screws (see Figure 10.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 39 Important Notice: Heat shields may not be fi eld constructed. H. Heat Shield Requirements for Horizontal T ermination W ARNING! Risk of Fire! T o prevent overheating and fi re, heat shields must extend through the entire wall thick- ness.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 40 INTERIOR Heat Shield or Extended Heat Shield W all Shield Firestop Heat Shield 1-1/2 in. (38 mm) min. overlap SHEA THING Slip Section can be extended Inner V ent Outer V ent EXTERIOR Figure 10.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 41 1 1 11 Shrouds • Chase top shrouds may be fi eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as speci fi ed. Improper construction may overheat chase top.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 42 Min. Base Dim Min. Height Min. Base Dim Figure 1 1.2 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min. Opening Width Min. Base Dimension Minimum Height Figure 1 1.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 43 B. Gas Connection W ARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure may cause explosion. • V erify inlet pressures. V erify minimum pressures when other household gas appliances are operating.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 44 D. Install Flame Solenoid • Remove the screw and knob from the variable regulator and discard. • Remove the nut from the regulator and discard. • Remove the bag containing a washer and blue and red plungers from the side of the fl ame control solenoid.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 45 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 46 C. Junction Box Installation If the box is being wired from the OUTSIDE of the appli- ance: • Remove the cover plate located on the outer shell - right side (see Figure 13.2). • Install the supplied Romex™ connector in the cover plate.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 47 1 4 14 Wall Fi nishing W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 48 1 1/2 in. MAXIMUM Air Flow Steel Stud Assy 1/2 in. Cement Board Wood Framing Sheetrock Figure 14.3 1/2 in. Sheetrock plus Wall Finishing to 1 in. B. Additional Decorative Finishing up to 1 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 49 1 5 15 Applianc e Setup Glass Latches Figure 15.1 Glass Assembly Removal A. Remove Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 50 Remove Plates Figure 15.3 Remove Three Plates Figure 15.6 Remove Decorative Steel Log Assembly • Center Burner T ube Air Shutter - Remove decorative steel log assembly by removing 3 screws, lifting up and out (Figure 15.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 51 IMPOR T ANT! This applianc e should be r un three t o f ou r hou rs on low on th e in i tia l s tart- up . T u rn it of f and le t it c ool complet ely . Remo ve a nd clean the g lass . Re ins tall the gl ass an d run the appliance for an additi onal 1 2 hours.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 52 A. IntelliFire (IPI) Ignition System 1 6 16 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 53 A. IntelliFire (IPI) Ignition System (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but continues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 54 1 7 17 Reference Materials 19 1/2 in. (495 mm) 29 1/2 in. (749 mm) 57 3/4 in. (1466 mm) 66 1/4 in. (1684 mm) 35 5/8 in. (904 mm) 15 1/8 in. (385 mm) 9 in. (229 mm) 2 1/4 in. (57 mm) 40 1/8 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 55 B. V ent Components Diagrams Figure 17.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pipe inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Height/Length 10-1/2 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 56 B. V ent Components Diagrams ( continued ) Figure 17.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 57 B. V ent Components Diagrams ( continued ) Figure 17.4 DVP V ent Components 7-1/4 in. (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW V ertical T ermination Cap (High wind) 14 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 58 B. V ent Components Diagrams ( continued ) Figure 17.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 64 D. Optional Components A B C D LDS33/LDS46 Decorative Shroud E D A C B LDS-BV Decorative Shroud 20 in.
Heat & Glo • LUX60 • 4062-1 16 • Rev . G • 4/1 1 65 E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle LUX60 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle LUX60 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle LUX60 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle LUX60 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle LUX60 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle LUX60 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle LUX60 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle LUX60 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.