Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 1 Models: RED40 RED40ST • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: _________________.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 4 = Contains updated information. 13 Finishing A. Splatter Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 B. Framing and Finishing Instructions . . . . . .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 7 C. BTU Speci fi cations MODEL: RED40, RED40ST LABORA TOR Y : Underwriters Laboratories, Inc.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dw.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 9 Figure 2.1 General Operating Parts/Clear Space. B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 10 E. Fixed Glass Assembly See Section 14.H. D. Decorative Doors and Fronts W ARNING! Risk of Fire! Install ONL Y doors or fronts approved by Hearth & Home T echnologies. Unapproved doors or fronts may cause fi replace to overheat.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 11 H. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait fi ve (5) minutes to clear out any gas.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 15 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 16 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 17 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 18 ABC Inches 48 17-1/4 36 Millimeters 1218 438 914 C C B A 1/2 IN. 1/2 IN. Figure 5.2 Appliance Locations RED40ST Note: Consider installation of the active con- vection blower when determining appliance location.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 19 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 20 Figure 5.5. Clearances to Combustibles-RED40ST MINIMUM FRAMING DIMENSIONS* AB C D E F G HI Rough Opening (V ent Pipe) Rough Opening (.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 21 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 22 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .........................
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 23 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches.....
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 25 Figure 7.4 T op V ent - Horizontal T ermination V enting with 1 elbow H 1 V 1 Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • AL WA YS maintain speci fi ed clearances around venting and fi restop systems.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 26 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 Figure 7.5 1. T op V ent - Horizontal T ermination - (continued) T op V ent - Horizontal T ermination V enting with 2 elbows Note : Use DVP Series components only .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 27 H 2 H 1 V 2 V 1 T op V ent - Horizontal T ermination V enting with 3 elbows Note : Use DVP Series components only . 1. T op V ent - Horizontal T ermination - (continued) Figure 7.6 V 1 + V 2 Minimum H Maximum 1 ft.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 28 Figure 7.7 V ertical V ent Maximum Note: If installing a vertical vent/termination of f the top of the appliance, the optional exhaust restrictor may be needed. V V = 3 ft Min. (1m), 50 ft.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 29 Figure 7.9 H 1 V 1 V 2 T op V ent - V ertical T ermination V enting with 2 elbows Note : Use DVP Series components only . V 1 + V 2 Minimum H Maximum 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 4 ft.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 30 Figure 7.10 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 T op V ent - V ertical T ermination V enting with 3 elbows Note : Use DVP Series components only . V 1 + V 2 Minimum H 1 + H 2 Maximum 1 ft.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 31 NOTE : Maximum total vent run= T otal vertical vent run + T otal horizontal vent run MAXIMUM VERTICAL DROP DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE MAX. ELBOWS (45° & 90°) MAX.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 32 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 33 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 34 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 35 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. A. Appliance Preparation 9 9 Appliance Preparation FIBERGLASS ROPE RING BOTTOM P ANEL SCREW LOCA TIONS 1.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 36 B. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 37 C. Active Convection T echnology H2 V1 H1 H1 MAX. = 8 FT . H1 + V1 + H2 = 8 FT . MAX. = TWO 90° BENDS INLET CONVECTION AIR MA Y BE VENTED IN ANY DIRECTION,INCLUDING DOWNW ARD. LOUVERED VENT CLEARANCE FROM INT AKE TO OBJECTS = 24 IN.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 38 1 0 10 Inst alling V ent Pi p e ( D VP Pipe ) Figure 10.2 High T emperature Silicone Sealant A.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 39 C. Secure The V ent Sections • Vertical runs of pipe must be supported every 8 ft. (2.44 m). • Horizontal sections must be supported every 5 feet (1.52 m). • V ent supports or plumbers strap (spaced 120º apart) may be used to support.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 40 D. Disassemble V ent Sections • Rotate either section (see Figure 10.7) so the seams on both pipe sections are aligned as shown in Figure 10.8. • Pull carefully to separate the pieces of pipe.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 41 F . Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.1 1) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 42 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.19 TERMINA TION CAP H. Install V ertical T ermination Cap • Attach the vertical termin.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 43 Figure 10.20 Venting Through the W all Note: W hen using te rminat ion c aps wit h factor y- suppli ed heat shield attached, no additional w all shield fi restop is required on the ex terio r side of a co mbustible wall.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 44 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 45 C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 46 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 47 NOTE: 1 . Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 V AC is required at junction box. Optional Remote Control Receiver Location A battery back up is not compatible with the RED40 or RED40ST and may not be installed.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 48 D. Optional LED Lighting Circuit POWER SUPPL Y LED LIGHTBAR ASSEMBL Y 6 LEAD W ALL CONTROL WIRE APPLIANCE ON/OFF CONTROL WIRE ASSEMBL.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 49 Figure 12.7 Junction Box Detail 1. Remove the one screw that secures the junction box to the control tray panel. 2. Route the wire through the strain relief in the outer wrap and down through the knockout located on top side of the junction box.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 50 4. Remove screws from each end of burner assembly . Pull burner out of appliance. Set aside. Figure 12.1 1. Side Burner Screw . SIDE BURNER SCREW 5. Remove left or right side glass pane frame, depending on placement of blower , from bottom of fi rebox.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 51 Figure 12.17. Remove Mounting Plate 1 1. Attach new blower to mounting plate by fastening the four screws in the appropriate locations. The side of the blower with the label on it must face toward the inside of the appliance.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 52 1 3 13 Finis hing B. Framing and Finishing Instructions W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 53 Figure 13.1 Finishing Details CAUTION! Risk of Glass Damage and Cuts! DO NOT drill or install any type of screw or fastener into the lower cover panel. Sharp screw or fastener tips may penetrate and break the glass or cause cuts.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 54 C. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 55 D. Facing Material • Facing and/or fi nishing materials must not interfere with air fl ow through louvers, operation of louvers or doors, or access for service. • Facing and/or fi nishing materials must never overhang into the glass opening.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 56 Non-Combustible Finish Materials 0 - 1 inch thickness-Overlap Fit Method The mesh front is designed to overlap fi nish materials 0 inches to 1 inch thick.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 57 Figure 13.10 Noncombustible Surface Finishing Material 0-4 Inches Thick-Inside Fit Method The mesh decorative front is approved for inside fi t ap- plications.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 58 E. Mesh Fronts W ARNING! Risk of Burns! A decorative front is required for this model. DO NOT operate this appliance without a decorative front in place. Only doors certi fi ed for use with this appliance model may be used.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 59 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. V erify all components are with the fi replace.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 60 Figure 14.4 Air Shutter Figure 14.3 Fixed Glass Assembly H. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 61 A. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 62 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 63 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 64 Figure 16.2 Appliance Dimensions RED40ST Location Inches Millimeters K 46-3/4 1 187 L 7 178 M 50-1/8 1273 N 25-1/16 637 O 18-1/8 460 .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 65 Figure 16.2 DVP vent components B. V ent Components Diagrams 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 66 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 67 B. V ent Components Diagrams (continued) Figure 16.5 DVP Series V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 68 B. V ent Components Diagrams (continued) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) 1 in. (25 mm) 14 in. (356 mm) 3/8 in.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 69 Optional Wire Harness DESCRIPTION P ART NUMBER 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness PVI-WH20 40 ft. PV Wire Harness PVI-WH40 60 ft. PV Wire Harness PVI-WH60 80 ft. PV Wire Harness PVI-WH80 100 ft.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 70 C. Service Parts RED40 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 71 C. Service Parts RED40ST Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ 40 in Landscape See-Thru DV Fireplace IMPORT ANT : THIS IS DA TED INFORMA TION.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 72 RED40,RED40ST Service Parts List Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 73 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ Service Parts RED40, RED40ST IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 74 Service Parts RED40 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 75 Service Parts RED40ST Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 76 Service Parts RED40 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ 16.1 16.2 16.3 16.4 16.5 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 77 Service Parts RED40ST Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 78 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ Service Parts RED40 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 79 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ Service Parts RED40ST IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 80 19.1 19.4 19.4 19.6 19.6 19.6 19.5 19.5 19.3 19.3 19.3 19.2 19.2 19.2 21.1 21.2 21.2 21.3 21.3 21.3 22.1 22.1 22.2 22.3 22.2 ITEM DESCRIPTION COMMENTS P ART NUMBER 19 Refractory Kit GR40-F 19.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 81 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ Service Parts RED40ST 19.1 19.2 19.1 19.3 19.3 19.4 19.4 19.3 19.3 19.3 19.3 19.1 19.2 19.1 20.1 20.2 20.1 20.3 20.
Heat & Glo • RED40, RED40ST • 2155-900 Rev . o • 7/12 82 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle RED40 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle RED40 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle RED40 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle RED40 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle RED40 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle RED40 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle RED40 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle RED40 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.