Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 1 Model: SLR-B (COSMO) • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Seria.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 4 = Contains updated information. 13 Finishing A. Framing and Finishing Instructions . . . . . . . . . . . . . . . . . 50 B. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++7D.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 7 C. BTU Specifi cations MODEL: SLR-B LABORA TOR Y : Underwriters Laboratories, Inc. (UL) TYPE: V ented Gas Fireplace Heater STANDARD: ANSI Z21.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling,.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 9 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 10 C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 1 1 H. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 14 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 15 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 16 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 17 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 18 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 19 C. Clearances NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 20 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 21 3-1/2 IN. 1 IN. AIR SP ACE NON-COMBUSTIBLE BOARD SHIPPED WITH APPLIANCE 1 IN. Figure 5.8 Non-Combustible Zone.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 22 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ................................
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 23 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches............
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 24 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies SLP venting systems. Refer to Section 16.B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 25 Figure 7.4 T op V ent - Horizontal T ermination V enting with 1 elbow H 1 V 1 V Minimum H 1 Maximum SLR-B 90 Elbow 1-1/2 ft. 457 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 26 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 Figure 7.5 1. T op V ent - Horizontal T ermination - (continued) T op V ent - Horizontal T ermination V enting with 2 elbows Note : Use SLP Series components only .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 27 H 2 H 1 V 2 V 1 T op V ent - Horizontal T ermination V enting with 3 elbows Note : Use SLP Series components only . 1. T op V ent - Horizontal T ermination - (continued) Figure 7.6 SLR-B V 1 Minimum H 1 + H 2 Maximum V 2 V 1 + V 2 Minimum 90° Elbow 6 ft.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 28 Figure 7.7 1. T op V ent - Horizontal T ermination - (continued) T op V ent - Horizontal T ermination V enting with 3 elbows Note : Use SLP Series components only .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 29 Figure 7.8 V ertical V ent Maximum Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. V 1 V 1 = 44 ft. Max. (13.4 m) T op V ent - V ertical T ermination No Elbows Note : Use SLP Series components only .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 30 Figure 7.1 1 H 1 V 1 V 2 T op V ent - V ertical T ermination V enting with 2 elbows Note : Use SLP Series components only . SLR-B V 1 Minimum H Maximum V 2 V 1 + V 2 Minimum 90° Elbow 2 ft. 610 mm * * 1 ft, 152 mm 3 ft.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 31 Figure 7.12 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 T op V ent - V ertical T ermination V enting with 3 elbows Note : Use SLP Series components only . SLR-B V 1 Minimum H 1 + H 2 Maximum V 2 V 1 + V 2 Minimum 90° Elbow 1 ft.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 32 T op V ent - V ertical T ermination V enting with 4 elbows Note : Use SLP Series components only . Note : There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 33 Clearances to Combustibles: Refer to Section 5 for clearances to the appliance, man- tel, mantel legs and wall projection. Refer to Section 8 for pipe clearances to combustibles. T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 34 EXISTING CHIMNEY HEARTH FLOOR EXISTING CHIMNEY EXHAUST AIR VENT PIPE INLET AIR VENT PIPE T o minimize cold air drafts, seal with non-combustible insulation. TERMINA TION CAP DIRECT VENT FIREPLACE V Figure 7.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 35 * When using SLP pipe, minimum clearances from the vent pipe to combustible materi- als at inside wall firestops are: T op: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 36 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • SLP pipe only - Frame opening 9 in. x 9 in. (229 mm x 229 mm) whenever the vent penetrates a ceiling/floor (see Figure 8.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 37 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 38 ELBOW HEA T SHIELD SHOWN IN SHIPPING POSITION CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. A.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 39 B. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 40 10 Installing V ent Pipe ( SLP P ip e ) Figure 10.2 High T emperature Silicone Sealant A. Assemble V ent Sections T o attach the fi rst vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar .
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 41 C. Secure The V ent Sections • Vertical runs of pipe must be supported every 8 ft. (2.44 m). • Horizontal sections must be supported every 5 feet (1.52 m). • V ent supports or plumbers strap (spaced 120º apart) may be used to support.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 42 D. Disassemble V ent Sections • Rotate either section (see Figure 8.7) so the seams on both pipe sections are aligned as shown in Figure 10.8. • Pull carefully to separate the pieces of pipe.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 43 F . Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.1 1) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 44 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.15 TERMINA TION CAP H. Install V ertical T ermination Cap • Attach the vertical termination c.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 45 Figure 10.17 V enting through the wall Note: Wh en using ter minati on c aps wi th fac tor y -sup plied he at shield attached, no additional wall shield fi restop is required on the ex ter ior s ide of a c om bustib le wall.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 46 11 Gas Informat ion A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies specifi ed and approved parts.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 47 C. Gas Connection • Refer to Reference Section 16 for location of gas line access in appliance.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 48 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 49 Figure 12.2 IntelliFire Pilot Ignition (IPI) Wiring Diagram with W all Switch or Thermostat E. Junction Box Installation 1. Bend junction box heat shield to the right along the perforated hand bends.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 50 13 Finish ing A. Framing and Finishing Instructions W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 51 W ARNING! Risk of Fire! Maintain specifi ed air space clearances to combustibles. Failure to comply with these instructions may cause a fi re or cause the appliance to overheat. F ACTOR Y -INST ALLED NON-COMBUSTIBLE BOARD LOWER COVER P ANEL = NO SCREWS ALLOWED = 1 INCH.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 52 V erify that the lower cover panel is installed correctly , and that the fi replace opening height is between 15-7/8 in. and 16-1/8 in. See Figure 13.4. Note: The lower cover panel must be pushed all the way down.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 53 B. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 54 Non-Combustible Finish Materials 0 - 1 inch thickness-Overlap Fit Method Both the T onic and Martini decorative fronts are designed to overlap fi nish materials 0 inches to 1 inch thick. See Figure 13.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 55 Non-Combustible Finish Material 0-4 Inches Thick Bottom Joint 3/4 IN. 3/4 IN. 3 IN. Figure 13.1 1 Noncombustible Surface Finishing Material 0-4 Inch Thick-Inside Fit Method (T onic Decorative Front Only) F ACTORY -INST ALLED NON-COMBUSTIBLE BOARD DR YW ALL OR EQUIV ALENT (1/2 IN.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 56 D. Decorative Fronts W ARNING! Risk of Fire! A decorative front is required for this model. DO NOT operate this appliance without a decorative front in place. Only doors certifi ed for use with this appliance model may be used.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 57 A. Remove Fixed Glass Assembly See Section 14.F . B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. The standard black rock media and manual bag assembly are also shipped underneath the fi rebox.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 58 Figure 14.3. Placing Glass Rock Media on Pilot Shield PILOT SHIELD Figure 14.4. Maintaining Media T ray Air Spaces.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 59 H. Air Shutter Setting Air shutter settings may be adjusted by a qualifi ed install- er at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 60 A. IntelliFire Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 61 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame rectifi cation has not occurred.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 62 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 63 Cap Shield DRC-RADIUS 13-7/8 in. (352 mm) 9-1/2 in. (241 mm) 14 in. (356 mm) COOL-ADD Cap Shield 11-5/8 in. (295 mm) 5-3/4 in. (146 mm) 7-1/8 in. (181 mm) 12-1/8 in. (308 mm) DVP-BEK2 DVP-HPC Cap Brick Extens 13-7/8 in.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 64 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 65 SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black B. V ent Components Diagrams (continued) Figure 16.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 66 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 67 Figure 16.10 Coaxial to Colinear V ent Components LINK-DV30B Flex Liner Kit DV -46DV A-GCL Coaxial/Colinear Appliance Connector DVP-2SL Adapter COAXIAL to COLINEAR VENTING B. V ent Components Diagrams (continued) Optional Wire Harness DESCRIPTION P ART NUMBER 10 ft.
Heat & Glo • SLR-B • 2195-900 Rev . P • 12/1 1 71 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle SLR-B (COSMO) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle SLR-B (COSMO) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle SLR-B (COSMO) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle SLR-B (COSMO) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle SLR-B (COSMO) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle SLR-B (COSMO) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle SLR-B (COSMO) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle SLR-B (COSMO) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.