Gebruiksaanwijzing /service van het product 13 SEER van de fabrikant Heat Controller
Ga naar pagina of 20
SPLIT SYSTEM AIR CONDITIONER USER’S MANU AL / INST ALLA TION INSTR UCTIONS R-22, 13 SEER USER INFORMA TION IMPORT ANT SAFETY INFORMA TION ................. 2 OPERA TING INSTRUCTIONS ............................... 2 Cooling Operation ...............
2 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or lev el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death.
3 INST ALLER INFORMA TION IMPORT ANT SAFETY INFORMA TION INST ALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual.
4 AIR CONDITIONER INST ALLA TION General Information Split system air conditioners are designed only f or outdoor rooftop or ground le v el installations.
5 Connecting Refrigerant T ubing Between the Indoor & Outdoor Unit CA UTION: This system uses R-22 refrigerant which may contain POE oil. When servicing, co ver or seal openings to minimize the exposure of the refrigerant system to air to prevent accum ulation of moisture and other contaminants.
6 • The outdoor unit requires both power and control circuit electrical connections. Refer to the wiring diagram / schematic f or identification and location of outdoor unit field wiring interfaces (Figure 11, page 17).
7 System Cooling 1. Set the ther mostat’ s system mode to COOL and the f an mode to A UT O. Gradually low er the ther mostat temperature setpoint belo w room temperature and v erify the outdoor unit and indoor blower energiz e. 2. V erify blow er wheel is spinning in direction indicated by arrow .
8 CA UTION: The unit should never be operated without a filter in the return air system. Replace disposable filters with the same type and size. • Do not attempt to add additional oil to motors unequipped with oil tubes.
9 TXV COOLING CHARGING CHARTS 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant w hen below curve Re mo ve re fr igerant w hen above curv e Figure 4.
10 Figure 5. Char ging Char t f or 2 T on Units (with Microchannel Coil) 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant w hen below curve Re mo ve re fr igerant w hen above curv e Figure 6.
11 Figure 7. Char ging Char t f or 3 T on Units (with Microchannel Coil) 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant w hen below curve Re mo ve re fr igerant w hen above curv e Figure 8.
12 Figure 9. Char ging Char t f or 4 T on Units 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant when below curve Re mo ve re fr igerant w hen above curv e Figure 10.
13 FIGURES & T ABLES Shaded bo x es indicate flooded conditions. Rated design v alues. The suction pressure will v ar y from design v alue if indoor air flo w , entering dry bulb , or entering wet bulb temperatures are lo wer than design. 1. All pressures are listed in psig and all temperatures in ° F 2.
14 Shaded bo x es indicate flooded conditions. Rated design values . The suction pressure will v ar y from design v alue if indoor air flo w , entering dry bulb , or entering wet bulb temperatures are lo wer than design. 1. All pressures are listed in psig and all temperatures in ° F 2.
15 Shaded bo x es indicate flooded conditions. Rated design values . The suction pressure will v ar y from design v alue if indoor air flo w , entering dry bulb , or entering wet bulb temperatures are lo wer than design. 1. All pressures are listed in psig and all temperatures in ° F 2.
16 T able 10. Char ging T able for 5 T on Units Suct. Press. OUTDOOR TEMPERA TURE (° F) 70 75 80 85 90 95 100 105 Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis.
17 Figure 11. Wiring Diagram Single Phase 1. Couper le courant av ant de f aire letretien. 2. Emplo yez uniquement des conducteurs en cuivr e. 3. Ne con vient pas aux installations de plus de 150 volt a la terre . 710570B (Replaces 710570A) 0109 WIRING DIA GRAM Split System Air Conditioner (Outdoor Section) NO TES: 1.
18.
19.
W ARRANTY INFORMA TION A warr anty cer tificate with full details is included with the air conditioner . Carefully re view these responsibilities with your dealer or service company .
Een belangrijk punt na aankoop van elk apparaat Heat Controller 13 SEER (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat Controller 13 SEER heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat Controller 13 SEER vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat Controller 13 SEER leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat Controller 13 SEER krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat Controller 13 SEER bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat Controller 13 SEER kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat Controller 13 SEER . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.