Gebruiksaanwijzing /service van het product DMH24DB-1 DMC36TB-1 van de fabrikant Heat Controller
Ga naar pagina of 29
DMC24DB-1, DMH24DB-1 DMC36TB-1, DMH36TB-1.
2 Room Air Conditioner Room Air Conditioner Installation Manual T ABLE OF CONTENTS Installation Parts Pro vided ......................................... 3 Safety Precautions ...................................................... 4 Installation of Indoor , Outdoor Unit .
Installation Manual 3 Installation P ar ts Provided Installation P ar ts Pr ovided Type "A" screws and plastic anchors Type "B" screws Holder Remote Control Installation plate Standard Type more than 70cm (27.6 inch) more than 30cm (11.
4 Room Air Conditioner Safety Precautions Safety Precautions T o pre vent the injury of the user or other people and proper ty damage, the follo wing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage.
Installation Manual 5 Safety Precautions ■ Operation Be sure the installation area does not deteriorate with age. • If the base collapses, the air conditioner could fall with it, causing proper ty damage, product failure , and personal injury . Install the indoor unit on the wall where the height from the floor s more than 8ft(2.
6 Room Air Conditioner Saf ety Precautions Stop operation and close an y window in storm or hurricane. before the hurricane arrives. • There is risk of proper ty damage, failure of product, or electric shock. Do not open the inlet grill of the product during operation.
Installation Manual 7 ■ Installation ■ Operation Do not direct airflow at room occupants. • This could damage your health. Do not use the product f or special purposes, suc h as preserving foods, works of art, etc. It is a consumer air conditioner , not a precision refrigeration system.
8 Room Air Conditioner Saf ety Precautions Use a soft cloth to c lean. Do not use harsh detergents, solvents, etc. • There is risk of fire, electric shock or damage to the plastic par ts of the product. Do not touch the metal parts of the product when removing the air filter .
Installation of Indoor , Outdoor Unit Installation Manual 9 Installation of Indoor , Outdoor Unit Read completely , then follow step b y step. Indoor unit 1. Do not ha ve an y heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit.
10 Room Air Conditioner Installation of Indoor , Outdoor Unit Multi Piping T ype Piping length and elev ation 24k 30m(100ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.
Installation of Indoor , Outdoor Unit Installation Manual 11 The wall y ou select should be strong and solid enough to pre vent vibration 1. Mount the installation plate on the w all with type "A" screws . If mounting the unit on a concrete wall, use anchor bolts .
12 Room Air Conditioner Flaring W or k and Connection of Piping Flaring W ork and Connection of Piping Flaring w ork Main cause f or gas leakage is due to defect in flaring work. Carry out correct flaring wor k in the f ollowing procedure. Cut the pipes and the cable.
Flaring W or k and Connection of Piping Installation Manual 13 Check 1. Compare the flared w ork with the figure by . 2. If a flared section is def ective, cut it off and do flaring work again. Indoor 1. Prepare the indoor unit's piping and drain hose f or installation through the wall.
14 Room Air Conditioner Flaring W or k and Connection of Piping 4. Indoor unit installation Hook the indoor unit onto the upper por tion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.
Flaring W or k and Connection of Piping Installation Manual 15 1. Route the indoor tubing and the dr ain hose to the required piping hole position. 2. Insert the piping, drain hose, and the connecting cable into the piping hole . 3. Inser t the connecting cable into the indoor unit.
16 Room Air Conditioner Flaring W or k and Connection of Piping Wrap the insulation material around the connecting portion. 1. Ov erlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there ma y be no gap .
Flaring W or k and Connection of Piping Installation Manual 17 Installation Inf or mation. F or left piping. F ollow the instruction below . Good case • Press on the upper side of clamp and unf old the tubing to downw ard slowly . Bad case • F ollowing bending type from right to left ma y cause damage to the tubing.
18 Room Air Conditioner Flaring W or k and Connection of Piping Outdoor Align the center of the pipings and sufficiently tighten the flare nut b y hand.
Connecting the Cable between Indoor Unit and Outdoor Unit Installation Manual 19 Connecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the indoor unit b y connecting the wires to the terminals on the control board individuall y according to the outdoor unit connection.
20 Room Air Conditioner Connecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the Outdoor unit. 1. Remo ve the co ver control from the unit b y loosening the screw . Connect the wires to the terminals on the control board individually as the f ollowing.
Connecting the Cable between Indoor Unit and Outdoor Unit Installation Manual 21 (1) Remov e two-caps on the conduit panel. (2) Make a hole appropriate f or the passage of connection cable through on cap b y tool. (f or low voltage line) (3) P ass the connecting cable through the hole .
22 Room Air Conditioner Connecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the indoor unit CA UTION! Provide a cir cuit breaker between the power sour ce and the outdoor unit as shown belo w . Size breaker per the Maximum Fuse or Circuit Breaker (MOC) rating on the unit rating plate.
Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Installation Manual 23 Chec king the Drainage, Forming the Pipings and Long Pipe Setting Chec king the drainage T o chec k the drainage. 1. P our a glass of water on the e v aporator .
24 Room Air Conditioner Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Forming the piping Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vin yl tape.
Air Purging and Evacuation Installation Manual 25 Air Pur ging and Ev acuation Air and moisture remaining in the refrigerant system hav e undesirab le effects as indicated belo w . 1. Pressure in the system rises. 2. Oper ating current rises. 3. Cooling(or heating) efficiency drops .
26 Room Air Conditioner Air Purging and Evacuation 1. Connect the charge hose end described in the preceding steps to the vacuum pump to e vacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold v alve is open. Then, r un the vacuum pump .
Charging Installation Manual 27 Char ging ■ Each outdoor unit is f actor y charged (nameplate charge) for the e vaporator as well as a 7.5m(25ft) line set f or each indoor line. Any time total line set is used either shorter or longer then the nominal 22.
28 Room Air Conditioner T est Running 1. Chec k that all tubing and wiring hav e been properly connected. 2. Chec k that the gas and liquid side ser vice valv es are fully open. Prepare remote control Remov e the batter y cov er by pulling it according to the arrow direction.
P/No . : 3828A22013Z Specifications and performance data subject to change without notice. HEA T CONTROLLER, INC. 1900 WELL WOR TH A VENUE • JACKSON, MICHIGAN 49203 THE QU ALITY LEADER IN CONDITIONI.
Een belangrijk punt na aankoop van elk apparaat Heat Controller DMH24DB-1 DMC36TB-1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat Controller DMH24DB-1 DMC36TB-1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat Controller DMH24DB-1 DMC36TB-1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat Controller DMH24DB-1 DMC36TB-1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat Controller DMH24DB-1 DMC36TB-1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat Controller DMH24DB-1 DMC36TB-1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat Controller DMH24DB-1 DMC36TB-1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat Controller DMH24DB-1 DMC36TB-1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.