Heat Controller , Inc. • 1900 Wellworth A ve. • Jackson, MI 49203 • (517)787-2100 • www .heatcontroller .com INST ALLA TION INSTR UCTIONS SMA/SMH 18/24 V ersion C Single Zone Ductless Mini-Spl.
SMA/SMH 18/2 4 INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 Installation Manual for Single Zone Ductless Mini-Split • For correct installation, read this manual before starting the installation.
Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 18/2 4 2 Part No. Name of Part Quantity 1 Installation Plate 1 2 Anchor 8 3 Mounting Screw A (ST3.
SMA/SMH 18/2 4 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 3 INDOOR UNIT INST ALLA TION 1. Mounting Installation Plate and creating a W all opening Installation Plate and its measurements (inches): 5 inches or more 5 inches or more 2. Creating a wall opening 1.
Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 18/2 4 4 2. Line Set and Condensate Drain Line B. When extending the drain hose, insulate appropriately . 1. Condenstate Drain 2. Line Set • Connect the indoor unit rst, then the outdoor unit.
SMA/SMH 18/2 4 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 3. Indoor Unit Installation secured to lip at the back Place the upper lip at the back of the indoor unit onto the up - per hook of the installation plate. Move the indoor unit from side to side to see that is is secured onto the hook of the installation plate.
Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 18/2 4 6 5. Connecting Cables C. Wrap cables not connected to terminals with electrical tape so that they will not touch any electrical components. B. A. Lift the panel, loosen the screw , then open the Electric Box Cover .
SMA/SMH 18/2 4 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 7 6. Piping and W rapping A. For the left-hand and right-hand piping, remove the rear plate bushing from the left side of the rear plate. B. Wind the line set, drain hose and wiring with tape se - curely and evenly .
Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 18/2 4 8 OUTDOOR UNIT INST ALLA TION 1. Outdoor Installation Precaution • Install the outdoor unit on a rigid base to prevent noise and vibration. • Locate the air outlet direction where the discharged air is not blocked.
SMA/SMH 18/2 4 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 9 3. Refrigerant Piping Connection 1. Flaring 2. Tightening Connection .04 A. B. A. B. Excessive torque can break the are nut. Ensure the proper torque is adhered to in the chart below .
Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 18/2 4 10 4. Wiring Connection A. Use a dedicated circuit. Use HACR break sized per unit’s rating plate. Size wires according to minimum circuit ampacity shown on the unit’s rating plate.
SMA/SMH 18/2 4 INST ALLA TION INS TRUCTIONS Heat Contr oller , Inc. 1 1 AIR PURGE AND TEST OPERA TION 1. Air Purge where L=Length • Open the valve stem until it hits against the stop. Do not try to open it further . • Securely tighten the valve stem cap with a spanner or wrench.
Heat Contr oller , Inc. INST ALLA TION INS TRUCTIONS SMA/SMH 18/2 4 12 2. Gas Leak Check 3. T est Operation soapy water . Make sure connections do not leak with leak detector or soapy water . A. Lo packed valve B. Hi packed valve C. End of indoor unit connection D.
04/2009 08/2010.
Een belangrijk punt na aankoop van elk apparaat Heat Controller SMA 18 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat Controller SMA 18 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat Controller SMA 18 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat Controller SMA 18 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat Controller SMA 18 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat Controller SMA 18 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat Controller SMA 18 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat Controller SMA 18 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.