Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 1 Models: GDST4336I GDFL4136I GDCR4136I GDCL4136I GDST4336 GDFL4136 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 4 = Contains updated information. 12 Electrical Information A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 B. Intelli fi re Ignition System Wiring .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 5 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnolog.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 6 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC).
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equip.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 9 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 12 J. Lighting Instructions (Standing Pilot) 1. Turn of f all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 13 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 15 B. Maintenance T asks-Quali fi ed Service T echnician The following tasks must be performed by a quali fi ed ser- vice technician.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 17 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 19 C A B D B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 20 C A B D Figure 5.3 Clearances to Combustibles G F I I E H * Adjust framing dimensions for interior sheathin.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 21 Note: All measurements in inches. Mantel Projection GDST4336I, GDST4336 Mantel Projection GDFL4136I, GDFL4136, GDCR4136I, GDCL4136I Note: All measurements in inches.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 22 TOP VIEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in. Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wall. Figure 5.10 Non-Combustible Zone (GDFL4136I, GDFL4136, GDST4336I, and GDST4336) Figure 5.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 23 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 24 K N O Q P V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.4 Minimum Clearances for T ermination A = 12 inches.........
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 25 B. Continue Adding V ent Components T o Install the Heat Shield: 1. Determine if the heat shield is required. Do so by measuring the vertical distance between the top horizontal surface of the elbow to any combustible surface above.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 26 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies a DVP venting system. Refer to Section 16B for vent component information.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 27 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.3. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 28 H 1 V 1 Figure 7.4 Figure 7.5 One Elbow T wo Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 1 Minimum H 1 Maximum Elbow only 2 ft. 610 mm 6 in. 152 mm 2-1/2 ft.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 29 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 2 ft.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 30 V 1 = 60 ft. Max. (18.3 m) V 1 = 3 ft. Min. (914 mm) 2. T op V ent - V ertical T ermination No Elbow NOTE: If installing a vertical vent/ termination off the top of the appli- ance, the optional vertical termina- tion baf fl e should be used.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 31 Figure 7.10 4. Center the exhaust restrictor in the open end of the ex- haust outlet and secure through the slots on the exhaust restrictor with the 2-1/4 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 32 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum One Elbow 3 ft 914 mm * * * 2 ft 607 mm 10 ft 3.1 m * * * 4 ft 1.2 m 20 ft 6.1 m * * * V 1 + V 2 + H 1 = 50 ft (15.2 m) Maximum *No speci fi c restrictions on this value EXCEPT V 1 + V 2 + H 1 cannot exceed 50 ft (15.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 33 3. Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45° Elbow H 1 = 18 in. (406 mm) Maximum H 1 H 1 DO NOT use a 45º elbow in corner installations.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 34 3. Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 2 V 1 H 1 INSTALLED HORIZONTALLY H 3 H 2 V 1 H 1 H 1 Maximum V 1 Minimum H 2 Maximum H 1 + H 2 Maximum 1 ft.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 35 4. Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 V 1 H 1 INST ALL ED HORIZONT ALL Y H 2 V 2 H 1 V 1 Minimum H 1 Maximum 6 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 36 4. Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 2 V 1 H 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 37 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 38 C. V ertical Penetration Framing Figure 8.3 Figure 8.4 Installing the Attic Shield 3 F ASTENERS PER SIDE IN.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 39 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 40 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 41 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. NOTICE: Once the vent cap has been removed it CANNOT be reattached.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 42 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose i.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 43 1 0 10 Inst all ing V ent Pi pe (D VP and SLP P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of t he pipe sect ions with the lanc ed tabs w ill face toward the applianc e.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 44 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 45 Figure 10.8 Securing V ertical Pipe Sections Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 46 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 47 G. Install Metal Roof Flashing Note : Skip this section if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 48 I. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.G. and 10.H) Pipe must be supported within 12 inches of the roo fl ine us- ing plumbers strapping or an SLP-FS when using the RF4- 8 Flashing.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 49 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 TERMINA TION CAP J.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 50 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 51 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 52 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 53 Figure 12.2 Intelli fi re Ignition Wiring Diagram with Wall Switch or Thermostat Figure 12.3 Intelli fi re Ignition Wiring Diagram with Remote Receiver NOTE: 1 .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 54 G. W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.6): • The power supply for the appliance must be brought into a switch box.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 55 1 3 13 Fi nishing A. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process be- fore fi nishing work on the whole hearth is complete.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 56 Step 5. Fold bottom fl ap along score line as indicated in Figure 13.6 and tuck into valve access area of appliance. Splatter guard should fi t securely on front of unit.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 57 B. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 58 Figure 13.16 Combustible Mantel Leg or W all Projections (Acceptable on both sides of opening) TOP V IEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 59 A. Remove Fixed Glass Assembly See Section 14H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 60 F . Install the Log Assembly Log Set Assembly: LOGS-2129 Models: GDST4336I, GDFL4136I, GDCL4136I, GDCR4136I, GBST4336I, GBFL4136I 2129-935 CAUTION! Logs are fragile! Carefully remove the logs and cardboard tray from the inside of the fi replace.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 61 STEP 2. Log #2 (SR V2129-705): Locate portion of Log #2 that is highlighted in Figure 5. Place that portion of Log #2 on the indentation on Log C. Log #2 will rest on the tip of Log B.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 62 Figure 1 1. Placement of Log #2 Figure 12. Placement of Log #2 Figure 13. Placement of Log #3 Figure 14. Placement of Log #3 STEP 2. Log #2 (SR V2129-705): Locate portion of Log #2 that is highlighted in Figure 1 1.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 63 I. Air Shutter Setting This appliance has an adjustable air shutter (which con- trols the primary air) factory set for the minimum vertical vent run (see Figure 12.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 64 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 65 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) c. V alve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 66 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. a. Incorrect wiring.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 67 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 68 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 69 Figure 16.2 GDFL4136I, GDFL4136 Dimensions B C FRONT VIEW RIGHT VIEW LEFT VIEW A P L Ø K D M O N E ELECTRI.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 70 Figure 16.3 GDCR4136I, GDCL4136I Dimensions B C FRONT VIEW RIGHT VIEW ELECTRICAL ACCESS GAS LINE ACCESS LEF.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 71 B. V ent Components Diagrams Figure 16.4 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 72 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 73 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 74 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 75 B. V ent Components Diagrams (continued) Figure 16.8 DVP vent components 13 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 76 B. V ent Components Diagrams (continued) EFFECTIVE HEIGHT/ LENGTH 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 77 SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-FLEX-TRAP Horizontal T ermination Kit SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black B.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 78 C. Service Parts Part number list on following page. Beginning Manufacturing Date: April 2008 Ending Manufa.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 79 Service Parts List GDST4336I, GDST4336 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 80 Service Parts Part number list on following page. Service Parts Diagram Beginning Manufacturing Date: April.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 81 Service Parts List GDFL4136I, GDFL4136 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 82 Service Parts Part number list on following page. Service Parts Diagram Beginning Manufacturing Date: April.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 83 Service Parts List GDCL4136I IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 84 Service Parts Part number list on following page. Service Parts Diagram Beginning Manufacturing Date: April.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 85 Service Parts List GDCR4136I IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 86 Intermittent Pilot Ignition V alve Assembly V alve Assembly Diagram/ Parts List GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I Service Parts Beginning Manufacturing Date: April 2008 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 87 Standing Pilot Ignition V alve Assembly V alve Assembly Diagram/ Parts List GDST4336, GDFL4136 Service Parts Beginning Manufacturing Date: April 2008 Ending Manufacturing Date: ______ 1 2 3 4 5 7 8 6 IMPORT ANT : THIS IS DA TED INFORMA TION.
Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev . F • 1 1/08 88 Heatilator , a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatilator .com D. Contact Information Please contact your Heatilator dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heatilator Gas Fireplace GDCL4136I (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heatilator Gas Fireplace GDCL4136I heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heatilator Gas Fireplace GDCL4136I vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heatilator Gas Fireplace GDCL4136I leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heatilator Gas Fireplace GDCL4136I krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heatilator Gas Fireplace GDCL4136I bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heatilator Gas Fireplace GDCL4136I kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heatilator Gas Fireplace GDCL4136I . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.