Gebruiksaanwijzing /service van het product Gas Fireplace IDV4833IH van de fabrikant Heatilator
Ga naar pagina of 64
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 1 Model(s): IDV4833IT , IDV4833IL T , IDV4833IH, IDV4833ILH, IDV6247IT , IDV6247IL T , IDV6247IH, IDV6247ILH Owner ’ s Manual Installation and Operation Installation and service of this appliance should be performed by quali fi ed personnel.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: ____________.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 4 Î = Contains updated information. 14 Appliance Setup A. Remove Shipping Materials 44 B. Remove Fixed Glass Assembly 44 C. Remove Materials Shipped Inside Firebox 44 D. Clean the Appliance 44 E.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 5 B. W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective bra.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 6 B. Limited Lifetime W arranty (continued) This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as de fi ned by the Consumer Product Safety Commission (CPSC).
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in eve.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 9 Decorative Doors (not shown) Section 2.D. Fixed Glass Assembly (not shown) Section 2.E. Grate (not shown) Section 2.B. Mantel Hearth (not required) Clear Space Section 2.C. Figure 2.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 10 Clear space 3 ft (914 mm) in front of appliance C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 1 1 H. Lighting Instructions (IPI) • For normal use, activate/deactivate your fi replace with the wall switch or remote control. • The IPI system may be operated with two D-cell batteries.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly .
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 14 Control Compartment and Firebox T op Frequency: Annually By: Quali fi ed Service T echnician T ools needed : Protective gloves, vacuum cleaner , dust cloths • V acuum and wipe out dust, cobwebs, debris or pet hair .
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 15 Noncombustible roof flashing maintains minimum clearance around pipe (SECTION 10) Ceiling Firestop on floor of attic (SECTION 8.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 16 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 17 5 5 F raming and C learanc es A. Select Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 18 C B A O in. 30 in. (762 mm) to ceiling 1-1/2 in. (38 mm) 1-1/2 in.(38 mm) Drywall 1/2 in. (13 mm) 0 in. D 0 in. T O LEVEL OF ST ANDOFFS Combustible Object 36 in. (914 mm) Combustible flooring may be installed next to the front of the appliance.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 19 Measured from top of fireplace opening (in inches) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 11 - 1 / 2 12-1/4 13 13-3/4 14-1/2 15-1/4 16 16-3/4 17-1/2 18-1/4 19 19-3/4 20-1/2 21-1/4 22 22-3/4 30 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 20 A. V ent T ermination Minimum Clearances Figure 6.1 Minimum Height From Roof T o Lowest Discharge Opening Horizontal overhang 12 X 20 in. (508 mm) Lowest Discharge Opening T ermination Cap Roof Pitch is X / 12 V ertical wall H (min.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 21 Dimension Descriptions A Clearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm) minimum. * B Clearance to window or door that may be opened – 10,000 BTUs or less, 6 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 22 Horizontal V ertical 8-1/2 in. 8-1/2 in. 12 in. On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216 mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP venting systems.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 23 H 1 V 1 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45° elbows. General Rules: • SUBTRACT 3 ft.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 24 4 ft min. (1.22 m) 25 ft max. (7.62 m) H 1 V 1 H 2 H 3 Installed Horizontally Installed V ertically H 2 Figure 7.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 25 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows H 1 V 1 V 2 H 2 Installed V ertically V 1 min. V 1 + V 2 max. H 1 +H 2 max. ft m ft m ft m 1 0.30 24 7.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 26 2. T op V ent - V ertical T ermination No Elbow Figure 7.7 Figure 7.8 T wo Elbows NOTICE: If installing a vertical vent/termination off the top of the appliance, the fl ue restrictor should be used.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 27 Figure 7.9 2. T op V ent - V ertical T ermination - (continued) Three Elbows 12 ft (3.66 m) min. 60 ft (18.29 m) max. Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 28 WA LL 1-1/2 in. (38 mm) 3 in. (76 mm) No combustible framing to be located within shaded area. 2 x 4 or 2 x 6 header Sheetrock Air space clearance to bottom and sides of horizontal pipe must be at least 1 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 29 3 fasteners per side Ceiling firestop installed below ceiling. Ceiling firestop installed above ceiling. Install attic insula- tion shields before or after installation of vent system.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 30 Bend all tabs inward 90° to maintain clearance and prevent insulation from falling inside Insert 3 screws Bend 4 tabs inward 90° to maintain clearance D. Install Attic Insulation Shield W ARNING! Fire Risk.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 31 Nailing T abs (both sides) A. Secure and Level the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose .
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 32 Lances 1 0 10 Install V ent Pipe A. Assemble V ent Sections Attach Pipe to the Firebox Assembly Note: The end of the pipe sections w ith the lanced t abs will face towards the applianc e.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 33 B. Assemble Slip Sections W ARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in. (38 mm). Secure slip sections with two screws which must not exceed 1/2 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 34 D. Disassemble V ent Sections • Rotate either section (see Figure 10.9) so the seams on both pipe sections are aligned as shown in Figure 10.10. • Pull carefully to separate the pieces of pipe.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 35 F . Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 36 G. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar . Pipe must be supported within 12 in. (305 mm) of the roo fl ine using plumbers strapping or an SLP-FS when us- ing the RF4-8 Flashing.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 37 Important Notice: Heat shields may not be fi eld constructed. I. Heat Shield Requirements for Horizontal T ermination W ARNING! Risk of Fire! T o prevent overheating and fi re, heat shields must extend through the entire wall thick- ness.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 38 INTERIOR Heat Shield or Extended Heat Shield W all Shield Firestop Heat Shield 1-1/2 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 39 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 40 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 41 NOTICE: DO NOT wire 1 10 V AC to wall switch. E. Junction Box Installation If the junction box is being wired from OUTSIDE of the appliance ( preferred method ): • Remove two screws that attach junction box and bracket to appliance.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 42 1 in. (25 mm) min. to perpendicular wall A 7.75 in. (159 mm) min. from fireplace opening to perpendicular wall B Mantel Leg or P.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 43 Z X Finishing Material Finishing Material (Finished Opening Width) X (Finished Opening Width) (Finished Opening Height) C.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 44 A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. • Front refractory (three pieces) package shipped in front of glass. • Lower decorative front face, left and right refractory shields shipped on top of front refractory box.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 45 H. Install the Logs • Base logs are pre-installed. • Place three top logs: Place slot in bottom of top log over pin in top of base log. Align opposite end of log with white notched area in top of base log.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 46 Rockwool Lava Rock Figure 12.7 Placement of Rockwool and Lava Rock I. Place Lava Rock and Rockwool Rockwool and lava rock are shipped with this gas appli- ance • Place rockwool on burner in front of front base log.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 47 Figure 12.9 Lift Glass Frame Assembly Forward Figure 12.10 Remove Left Side of Glass Frame First Decorative Screen Front Glass F.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 48 K. Decorative Firescreen, Refractory Shields and Lower Decorative Front Face • Install the decorative fi rescreen by fi rst inserting the left side of the screen rod into the horseshoe-shaped cradle (see Figure 12.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 49 L. Installing External Refractories Open Refractory Package (Figure 12. 1 7) • 1 - LH side refractory panel • 1 - RH side refractory panel • 1 - Front hearth refractory panel Right Left Front Hearth Notches indicate top of refractory Figure 12.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 50 M. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed installer at the time of installation. The air shutter is set at the factory for minimum vertical vent run.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 51 A. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 52 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but continues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 53 1 6 16 Re ferenc e Materials B D E 1 in. 25 mm 29-1/2 in. 749 mm C A Gas Line Electric Line 9-7/8 in. 251 mm 13-3/8 in. 340 mm 2 in. 51 mm 2-1/4 in. 57 mm F 21-1/2 in. 546 mm A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 54 B. V ent Components Diagrams Figure 16.2 DVP V ent Components Effective Height/Length DVP Pipe (see chart) Pi p e inches mm DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 - 6 76 - 152 DVP12A 3 - 12 76 - 305 Effective Height/Length 10-1/2 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 55 B. V ent Components Diagrams ( continued ) Figure 16.3 DVP V ent Components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (698 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 56 B. V ent Components Diagrams ( continued ) Figure 16.4 DVP V ent Components DVP-TB1 Basement V ent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 57 B. V ent Components Diagrams ( continued ) Figure 16.5 DVP V ent Components DVP-TRAP1 DVP-TRAP2 DVP-HPC1 DVP-HPC2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 58 B. V ent Components Diagrams (continued) Figure 16.6 DVP V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 59 C. Service Parts Service Parts 11 / 0 8 5 4 3 2 10 6 8 7 11 13 12 14 16 9 15 17 Service Parts Diagram IDV4833IT , IDV4833IH Part number list on following page. 1 Log Set Assembly Beginning Manufacturing Date: Jan.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 60 C. Service Parts (continued) Service Parts 11 / 0 8 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 61 C. Service Parts (continued) Service Parts 10/08 5 4 3 2 10 6 8 7 11 13 12 14 16 9 15 17 1 Log Set Assembly 47 in. ICON Gas Appliance - DV IDV6247IT , IDV6247IH Part number list on following page.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 62 C. Service Parts (continued) Service Parts 10/08 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 63 D. Optional Components Part # Description DF-PORT33-BK Portfolio black decorative front DF-PORT33-BZ Portfolio bronze decorative.
Heatilator • ICON DV -IDV Series • 4042-575 • Rev K • 1 1/08 64 E. Contact Information Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer , please visit www .heatilator .com.
Een belangrijk punt na aankoop van elk apparaat Heatilator Gas Fireplace IDV4833IH (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heatilator Gas Fireplace IDV4833IH heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heatilator Gas Fireplace IDV4833IH vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heatilator Gas Fireplace IDV4833IH leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heatilator Gas Fireplace IDV4833IH krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heatilator Gas Fireplace IDV4833IH bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heatilator Gas Fireplace IDV4833IH kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heatilator Gas Fireplace IDV4833IH . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.