Gebruiksaanwijzing /service van het product Iron Curtain System van de fabrikant Hellenbrand
Ga naar pagina of 28
For systems manufactured after October 1997 Manufactured by: HELLENBRAND, INC. 404 Moravian Valley Road • PO Box 187 Waunakee, Wisconsin 53597 Phone: 608-849-3050 • Fax: 608-849-7398 Web: www.
2 Congratulations on your purchase of one of the finest water treatment systems available today – the Iron Curtain System. This patented, non-chemical filter system, when properly applied will remove iron, manganese and/or hydrogen sulfide from your water supply.
3 INST ALLA TION DA T A Date of Installation _______________________________________ Model No.___________________________________ Address of Installation ______________________________________________.
4 IRON CUR T AIN the way to solve this problem is to use layers of media.” The advantages of a multi-media bed are: 1. Longer runs between backwash times. 2. Caking of the bed and breakthrough of turbidity are virtually eliminated. 3. Much higher service flow rates per square foot.
5 Operating Conditions The Iron Curtain System has been validated by the WQA under their S-200 Filter Standard for the reduction/removal of iron, manganese, and/or hydrogen sulfide.
6 Caution: The water pressure is not to exceed 70 p.s.i.; water temperature is not to exceed 110 ° F; conditioner cannot be subject to freezing conditions; conditioner cannot be subject to a negative pressure or vacuum.
7 Instructions for Adding IC pH Correction Media See Figures 1, 2 & 3 on page 8.. 1. Place Iron Curtain System on bypass. (Close inlet and outlet valves and open bypass valve.) 2. Relieve pressure by manually advancing timer to back- wash position (see page 10).
8 Due to existing plumbing conditions, you may want to choose an alternate installation configuration. Refer to Figures 2 and 3 below for alternate installation diagrams. FIGURE 1 Carefully place a pry bar (long screwdriver, wrench, etc.) between the screws and apply pressure clockwise until tight.
9 How T o Set T imer 1 How to set days on which water conditioner is to regenerate. Rotate the skipper wheel until the number "1" is at the red pointer. Set the days that regeneration is to occur by sliding tabs on the skipper wheel outward to expose trip fingers.
10 How T o Manually Regenerate Y our W ater F ilter At Any T ime Slowly turn the manual regeneration knob clockwise until the drive motor starts running. The movement of the manual regeneration knob engages the program wheel and starts the regeneration program.
11 How T o Set Regeneration Cycle Program 1 How to set the regeneration cycle program. The regeneration cycle program on your Iron Curtain Filter has been factory preset, however, portions of the cycle or program may be lengthened or shortened to suit local conditions.
12 Iron Curtain System Iron Curtain Wiring Diagram 1 2 3 WHITE BLK/WHT GREEN GREEN BLACK WH WHITE BLK/WHT BROWN YELLOW RED BLACK WHITE BLK/WHT BROWN YELLOW RED BLACK BLACK BLACK BLACK BLACK/WHITE TIME.
13 Iron Curtain T imer Assembly ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 49-13870 ....... Timer Housing 2 ..................... 1 ............. 49-13011 ....... Cycle Actuator Arm 3 ..................... 1 .
14 Iron Curtain Control Drive Assembly 32 10 7 9 11 12 8 4 13 14 1 2 31 33 17 16 18 19 28 30 29 26 25 24 21 20 27 34 23 15 ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 22-01 ............. IC Air Pump 2 ........
15 Iron Curtain Aeration Pump Item Part No. No. Description Qty. 1 .......... 74-625646 .............. Screw/Head .................................... 4 2 .......... 74-660631-504 ....... Head ............................................... 1 3 ......
16 Iron Curtain Aeration Pump Repair Instructions Air pump must be removed from tank and have power supply disconnected before proceeding. 1. Remove four front cover screws and remove front cover and cover gasket. 2. Remove four pump head screws and remove pump head.
17 IC-10 Series Control V alve Assembly ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 ..................... 1 ............. 49-11212NP .. Nickel Valve Body 2 ..................... 1 ............. 49-10757 ....... End Spacer 3 ..................... 6 .
18 1 IC-12 Series Control V alve Assembly 14 1 2 3 4 5 11 10 9 8 7 6 12 13 15 12 19 20 16 17 18 ITEM NO. NO. REQ'D. PART NO. DESCRIPTION 1 .............. 1 ................... 49-14749-02NP .. Nickel Valve Body 2 .............. 1 ................
19 Instructions for Replacing Piston Assembly and Seal Kit Replacing Piston Assembly See pages 17 and 18 for Parts Diagrams. 1. Place Iron Curtain System on bypass. (Close inlet and outlet valves and open bypass valve.) See Figures 1, 2 & 3 on page 8.
20 Removing Power Head Removing Seal from Valve Body Piston Back Plate Seal Hook to Remove Seals Seal FIGURE 14 FIGURE 15 8. Using the puller, remove the first spacer. 9. Alternately remove the remaining seals and spacers in accordance with steps #7 and 8.
21 Removing Spacer from Valve Body Replacing Spacer in Valve Body Placing Seal in Brass Sleeve of Stuffer Removing Stuffer from Valve Body after Inserting Seal Puller to Remove Spacers Stuffer to Replace Spacers and Seals Spacer Stuffer Seal FIGURE 18 FIGURE 19 FIGURE 16 FIGURE 17 24.
22 IRON CURT AIN FLOW DIAGRAMS Step 1. Service Position Raw water enters the aeration- tank inlet, flows thru the inlet diffuser, thru a head of air, down thru the aeration tank, thru the pick-up tube, out the aeration head, into the filter control inlet, and down thru the multi-media bed.
23 Step 3. Bleeding Off the Aeration System The Iron Curtain Control Center automatically shifts the controller into the Aeration recharge cycle. The air bleedoff valve opens up and allows raw water and/or air to pass thru the bleed off tube in the aeration tank to the drain.
24 Step 5. Bleeding Off Excess Air The Iron Curtain Control Center automatically turns the air com- pressor pump off and allows both valves to remain open. The air bleedoff valve will bleed off any excess air which was pumped in during the previous step and the check valve in the recharge line prevents any backflow into the air compressor system.
25 1a. Clean or replace drain line flow control 2a. Check for minimum specified flow and pressure requirements of filter system 3a. (Generally will only plug with the presence of iron bacteria) Clean aeration assembly and shock treat the water supply with chlorine as needed to control iron bacteria 4a.
26 Complaint Problem Cause Solution A. Dirt lodged under seat of valve B. Faulty or defective relief valve A. This can be expected when water is aerated under pressure A. See complaint #1 problem A & B A. Inlet check valve not sealing A. Reduced pressure in distribution system A.
27 Winterizing Iron Curtain Systems (Optional) In certain climates where houses and/or cottages are not heated during the winter months, Iron Curtain Systems must have the water removed from them to protect from damage due to freezing. Following are instructions for “winterizing” Iron Curtain Systems.
28 73-510 7/03-2500 IRON CURT AIN FIL TER SYSTEMS LIMITED W ARRANTY Hellenbrand, Inc., warrants to the original consumer/purchaser against defects in material and/or workmanship from the date of the o.
Een belangrijk punt na aankoop van elk apparaat Hellenbrand Iron Curtain System (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hellenbrand Iron Curtain System heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hellenbrand Iron Curtain System vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hellenbrand Iron Curtain System leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hellenbrand Iron Curtain System krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hellenbrand Iron Curtain System bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hellenbrand Iron Curtain System kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hellenbrand Iron Curtain System . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.