Gebruiksaanwijzing /service van het product 707U van de fabrikant Herrmidifier Co
Ga naar pagina of 16
Introduction ........................................1 Specifications ......................................1 Capacity Selection Guide ..................2 Operation of Humidifier ....................2 Installation Selecting a Location ................
1 Dear Owner: Congratulations on your choice of a Herrmidifier brand humidification system. Y our family can now look forward to breathing more comfortable air , winter after winter . W e are committed to providing advanced products that improve the quality of the air you breathe.
2 Capacity Selection Guide Operation Y our centrifugal atomizer type humidifier operates on the principle of breaking down water droplets into a fine mist and atomizing the moisture into the air .
3 Selecting a location for the unit Mounting on face of vertical return duct or side of horizontal return duct When mounting your humidifier on the face of a horizontal return duct, or on the face of .
4 Selecting a location for the unit Mounting behind a wall using the discharge extension (707U only) When selecting a location for the installation of your humidifier as a free standing unit, certain conditions must be met for its proper operation: Locate the humidifier in a convenient spot where the working part of the humidifier can be hidden (i.
5 Physical installation Caution: Only a trained HV AC servicer or contractor should install this humidifier . Do not connect the unit to the power source until installation is complete. A thorough checkout of the unit installation should be completed before operation.
6 Mounting on the face of a vertical return duct or side of a horizontal return 1. Mount the installation template on the side of the cold air return air duct with the center line of the template lined up with the center line of the return air duct. The narrow side of the duct may be used if space permits.
7 Mounting behind a wall using discharge extension (707U only) 1. Locate the inside wall template and mount on inside wall. The inside wall opening must be cut first. Be sure to follow the limitations noted as A, B, and C printed on the template. 2. Check the template with a level to ensure proper installation of the humidifier .
8 11. Before mounting the humidifier in its final position, carefully rotate the impeller assembly by hand to ensure it rotates freely . Mount the humidifier on the wire mounting bracket with the float and valve assembly connection facing the most convenient location, but providing the least obstruction to traffic.
9 Physical installation Final installation steps for all mounting locations • Install the saddle valve on the nearest cold water supply pipe (see the instructions on the package). If applicable, connect the saddle valve upstream of any type of water softener .
10 Electrical installation This humidifier is intended to be wired directly to the integrated control panel on your furnace. The electrical tap will provide power to the humidifier whenever the circulating air blower is in operation.
11 Humidistat: 1. Locate the humidistat in the living area (see location of humidifier diagram on page 4), making sure that it is at least five (5) feet from a supply register (duct mounted installation) or discharge nozzle (free standing installation).
12 Maintenance To enjoy the benefits of a properly humidified environment, periodic cleaning is necessary to control both water and household impurities. Film or scum, which can contain bacteria or fungi, may appear on the water surface, the sides, or bottom of your humidifier .
13 Maintenance instructions for models mounted on the face of a vertical return duct, side of a horizontal return duct, or mounted behind a wall using discharge extension Y our humidifier is constructed from quality materials to assure superior performance during normal operation.
4 2 3 1 15 16 17 5 8 9 10 11 12 13 14 7 6 14 Parts List ITEM 707U-UK 707U PART NO. DESCRIPTION 11 14 0 DISCHARGE DOME 21 1 252413-001 MOTOR COVER 34 41 9 RET AINER CLIP 41 1 352728-001 MOTOR BASE 51 1.
Wa rranty Humidifier Limited T wo Y ear W arranty This limited warranty covers Herrmidifier Residential T ype Humidifiers, excluding duct work, wiring and installation. The manufacturer warrants that all new Herrmidifier Humidifiers are free from defects in material and workmanship under normal, non-commercial use and service.
Een belangrijk punt na aankoop van elk apparaat Herrmidifier Co 707U (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Herrmidifier Co 707U heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Herrmidifier Co 707U vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Herrmidifier Co 707U leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Herrmidifier Co 707U krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Herrmidifier Co 707U bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Herrmidifier Co 707U kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Herrmidifier Co 707U . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.