Gebruiksaanwijzing /service van het product ONRB van de fabrikant Hill Phoenix
Ga naar pagina of 44
HANDBOOK INST ALLA TION & OPERA TION REACH-IN BEVERAGE CASES P057333G Rev . 12 6/06 MODEL: ORB, ORBH, ONRB & ONRBH COMPONENT.
.
Welcome to the ORIGIN 2 display case family . We’r e very pleased you joined us. This installation and operation handbook has been especially prepar ed for everyone involved with ORIGIN 2 display cases – owners, managers, installers and maintenance personnel.
.
1 T ABLE OF CONTENTS GENERAL INFORMA TION – P AGES 3 - 8 General information, first step recommendations and case dimensional drawings. THE USE OF CASTERS – P AGE 9 Cases roll on casters–general use and caster r emoval. LINE-UP – P AGES 10 - 11 A twelve step procedur e for initial case lineup with illustrations.
2.
3 GENERAL INFORMA TION DESCRIPTION OF CASES : The refrigerated display cases described in this handbook are part of the Hill PHOENIX , Origin 2 design series. Specifically cover ed in this manual are models ORB reach-in beverage, ORBH high r each-in beverage, ONRB narrow r each-in bev- erage, & ONRBH high narrow r each-in beverage.
4 41 7/16 in [105.2 cm] 81 1/4 in [206.3 cm] 83 1/4 in [211.5 cm] 6 13/16 in [17.2 cm]* 42 11/16 in [108.4 cm] COIL PLENUM 30 7/8 in [78.4 cm] 59 in [149.9 cm] 62 3/8 in [158.4 cm] (Door Height) 64 in [162.6 cm] (Frame Height) C L 34 11/16 in [88.1 cm] 31 9/16 in [80.
5 NO TES: * STUB-UP AREA ** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS z ENDS ADD APPRO XIMA TEL Y 1 INCH T O CASE HEIGHT z WIRING-TO-THE-T OP- ADDS APPRO XIMA TEL Y 1 INCH T O CASE .
6 C L NO TES: * STUB-UP AREA ** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS z ENDS ADD APPRO XIMA TEL Y 1 INCH T O CASE HEIGHT z WIRING-TO-THE-T OP- ADDS APPRO XIMA TEL Y 1 INCH T O C.
7 NO TES: * STUB-UP AREA ** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS z ENDS ADD APPRO XIMA TEL Y 1 INCH T O CASE HEIGHT z WIRING-T O-THE-T OP- ADDS APPRO XIMA TEL Y 1 INCH T O CASE.
149 1/4" 97 3/16" 48 7/16" 5 DOOR CASE FRONT OF CASE 119 1/4" (4dr CASE) 143 1/4" (12' CASE) 38 13/16" (4dr CASE) 44 5/8" (12' CASE) 4 DOOR CASE FRONT OF C.
9 CASES MOVE ON CASTERS FOR EASIER INST ALLA TION ORIGIN 2 cases are manufactur ed and shipped to stores with casters installed on the base frame to make the job of moving cases easier for everyone involved with the manufacturing, shipping and instal- lation process.
10 5 Set Shims On Basehorse Locations Locate basehorse positions along chalk lines. Spot shim packs at each basehorse location. LINE UP 1 Consult With General Contractor Ask the general contractor if there have been changes in the building dimensions since the print you are using was issued.
11 Ask about our case installation video available by request thr ough your local Hill PHOENIX Sales or Field Service Representative. 12 Add Sealant to T op Case Joint. Once cases are pushed tightly togeth- er and bolted run a bead of sealant along the top joint.
12 56 Apply acrylic tape over pipe chase seam. T ape is found with the ship loose items and acts as a watershed preventing water from settling in case joint. Seal joints along pipe chase seam with the caulk provided. Now that cases have been positioned and leveled, you may proceed to trim-out case line- up.
11 10 9 12 Attach the upper kickplate retainer , which is shipped loose with the case. Line up the retainer with the kickplate bracket and secure with the scr ews provided. The kickplate brackets ar e shipped loose with the ORZ and ORZH models but come installed on the ONRZ and ONRZH models.
C L 31 9/16 in [80.2 cm] (ST AND ARD) 35 1/8 in [89.2 cm] (ST AND ARD) ** 28 5/8 in [72.7 cm] (ST AND ARD) 39 1/4 in [99.7 cm] (ST AND ARD) REFRIGERA TION 1 1/2 in [3.
15 PLUMBING The drain outlet is located front and center of the cases for convenient access and is especially molded out of ABS material. The “P” trap, furnished with the case, is construct- ed of schedule 40 PVC pipe. Care should be given to assure that all connections ar e water tight and sealed with the appropriate PVC or ABS cement.
16 ELECTRICAL HOOKUP For case-to-case wiring, run “greenfield”, or other conduit, between junction boxes. When connecting to the junction box on the bottom left side of the case, field wiring should exit the junction box from the right hand side, furthest away from case wiring, incr easing room inside for wire connecting.
17 BALLASTS ACCESS The electronic ballasts that operate the vertical prism door lights ar e located in the door frame for Anthony ® door frames. ANTHONY ® FRAMES 1. REMOVE CORNER BEADS (2) 2. REMOVE ACCESS COVER 3. REPLACE BALLAST ANTHONY ® FRAMES STEPS TO REPLACE THE BALLAST 1 .
18 BALLAST LOCA TIONS PO WER LEADS LAMP LEADS LAMP 1 LAMP 2 LAMP 3 FIL TER BALLAST FOR LAMP 2 BALLAST FOR LAMPS 1 & 3 PO WER LEADS LAMP LEADS LAMP 1 FIL TER BALLAST FOR LAMPS 3 & 4 LAMP 2 LAMP.
19 PO WER LEADS LAMP LEADS LAMP 1 FIL TER BALLAST FOR LAMPS 4 & 5 LAMP 2 LAMP 3 LAMP 4 LAMP 5 BALLAST FOR LAMP 3 BALLAST FOR LAMPS 1 & 2 PO WER LEADS LAMP LEADS LAMP 1 BALLAST FOR LAMPS 5 &.
20 WIRING DIAGRAMS- 15 16 ORB, ORBH, ONRB & ONRBH 2 DOOR.
21 WIRING DIAGRAMS- 15 16 ORB, ORBH, ONRB & ONRBH 3 DOOR - 8’.
22 WIRING DIAGRAMS- 15 16 ORB, ORBH, ONRB & ONRBH 4 DOOR - 12’.
23 WIRING DIAGRAMS- BLACK WHITE RED C15706P1 HARNESS YELLOW/BLACK YELLOW YELLOW BLUE COMP. ROOM COMP. ROOM OPT DEFROST 19 120V LIGHTS 12 21 11 23 20 208/240V L1 WHITE YELLOW GREEN BLACK YELLOW BLK 120V FANS 54 3 WHITE INSIDE CASE M1 FAN MOTOR J4 P4 M2 FAN MOTOR M5 FAN MOTOR TO TO OR J.
24 WIRING DIAGRAMS- BLACK WHITE RED C15706P1 HARNESS YELLOW/BLACK YELLOW YELLOW BLUE COMP. ROOM COMP. ROOM OPT DEFROST 19 120V LIGHTS 12 21 11 23 20 208/240V L1 WHITE YELLOW GREEN BLACK YELLOW BLK 120V FANS 54 3 WHITE INSIDE CASE M1 FAN MOTOR M2 M5 TO TO OR J.
25 WIRING DIAGRAMS- GFI.
26 CASE OPERA TION Glass Door Reach-in Beverage Mer chandiser ORB - 2, 3, 4, 5 & 6-door All measurements are taken per ARI 1200 - 2002 specifications. Medium T emperature Defrost Schedule No. Per Day Hours 1 12 midnight 2 12 am - 12 pm 3 6 am - 2 pm - 10 pm 4 12 - 6 am - 12 - 6 pm COMPONENT 5 If timed off defrost is utilized.
27 High Glass Door Reach-in Beverage Mer chandiser ORBH - 2, 3, 4, 5, 6-door , 8’ & 12’ COMPONENT All measurements are taken per ARI 1200 - 2002 specifications. Medium T emperature Defrost Schedule No. Per Day Hours 1 12 midnight 2 12 am - 12 pm 3 6 am - 2 pm - 10 pm 4 12 - 6 am - 12 - 6 pm 1 Not applicable.
28 CASE OPERA TION 1 Not applicable. All measurements are taken per ARI 1200 - 2002 specifications. Medium T emperature Defrost Schedule No. Per Day Hours 1 12 midnight 2 12 am - 12 pm 3 6 am - 2 pm - 10 pm 4 12 - 6 am - 12 - 6 pm 6 If timed off defrost is utilized.
29 1 Not applicable. All measurements are taken per ARI 1200 - 2002 specifications. Medium T emperature Defrost Schedule No. Per Day Hours 1 12 midnight 2 12 am - 12 pm 3 6 am - 2 pm - 10 pm 4 12 - 6 am - 12 - 6 pm Maximum Lighting 120 V olts Amps 1.50 1.
30 DEFROST AND TEMP CONTROL This case is equipped with either Electric, Hot Gas, or Timed-Off defr ost at the owners option. The sensor bulb and probe for electric defrost termination contr ol, the se.
31 AIR FLOW AND PRODUCT LOADING Cases have been designed to provide maxi- mum product capacity within the r efrigerated air envelope. It is important that you do not overload the food product display so that it impinges on the air flow pattern. DISCHARGE.
32 USE AND MAINTENANCE CASE CLEANING Case is designed to facilitate cleaning. There is a wide radius formed on the front and back of the inside bottom of the tank (ORB & ORBH) that helps accelerate liquid flow and eliminates difficult-to-clean sharp corners.
33 37 37 37 37 37 37 37 37 37 37 37 37 37 37 F ANS The evaporator fans are equipped with either 9 watt fan motors, 1550 RPM’ s, or 12 watt fan motors, 1650 RPM’ s. Both motors have a counter clockwise rotation when viewed fr om the shaft end. The fan blades are 8” in diameter and the blades ar e pitched as shown on the chart below .
34 P AR TS ORDERING 23 24 11 9 1 2 17 88 E02 E01 55 4 87 10 15 20 23 E08 E09 E11 E10 E20 12 13 69 81 82 83 25 56 78.
35 Model ORB, ORBH, ONRB & ONRBH Location Part Descriptions Number 1 Kickplate , Storm Grey 2 Master Bumper , 3/4, 1/2, Featherstone, Smoke, White, French V anilla, Black 3 Lower Front Panel , Pai.
36 P AR TS ORDERING Procedure 1. Contact the Service Parts Department Hill PHOENIX 1925 Ruf fin Mill Road Colonial Heights, Virginia 23834 T el: 800-283-1109 Fax: 804-526-3897 2. Pr ovide the following information about the part you are or dering: • Model number and serial number of the case on which the part is used.
37 APPENDIX - A CLEANING INSTR UCTIONS FOR ANTIFOG CO A TING Antifog Coating Cleaning Instructions (ANTIFOG B): Materials CA UTION: 1. Only use deionized or distilled w ater with 2% cleaning solution (P/N 05-14700-0001) to clean the antif og coating.
38 NOTES.
6/00 W ARRANTY HEREINAFTER REFERRED TO AS MANUF ACTURER FOURTEEN MONTH W ARRANTY . MANUF ACTURER’S PRODUCT IS WARRANTED TO BE FREE FROM DEFECTS IN MA TERIAL AND WORKMANSHIP UNDER NORMAL USE AND MAINTENANCE FOR A PERIOD OF FOURTEEN MONTHS FROM THE DA TE OF ORIGINAL SHIPMENT .
1925 Ruffin Mill Road, Colonial Heights, V A 23834 Due to our commitment to continuous improvement all specifications are subject to change without notice. Hill PHOENIX is a Sustaining Member of the American Society of Quality . Visit our web site at www .
Een belangrijk punt na aankoop van elk apparaat Hill Phoenix ONRB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hill Phoenix ONRB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hill Phoenix ONRB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hill Phoenix ONRB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hill Phoenix ONRB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hill Phoenix ONRB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hill Phoenix ONRB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hill Phoenix ONRB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.