701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 34838 (Nov. 2002) HOBAR T HGF SERIES GAS FR YERS WITH OR WITHOUT FIL TER MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-.
– 2 – IMPOR T ANT FOR Y OUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
– 3 – TABLE OF CONTENTS GENERAL ............................................................................................................................................. 4 SPECIFICATIONS ........................................................
– 4 – INST ALLA TION, OPERA TION AND CARE OF HG SERIES GAS FR YERS SA VE THESE INSTRUCTIONS GENERAL Hobart HGF Series Gas Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance.
– 5 – OPTIONS AND FEATURES (Non-Filter Ready Fryers) • Stainless Steel Tank (Standard) • Tri-, Twin- or Single-Basket (Twin Standard) • Manual Pilot (Standard) BATTERY CONFIGURATIONS (Non-Fi.
– 6 – OPTIONS AND FEATURES (Filter-In-A-Drawer Filtration System) • Stainless Steel Tank (Standard) • Basket Lift with Timer • Tri-, Twin- or Single-Basket (Twin Standard) • Manual Pilot (.
– 7 – 4 Cabinets in Battery (For Gas 35, 45 and Electric 50 Only) ABC D Filter Fryer Fryer Fryer Dump ABC D Filter Fryer Dump Fryer Fryer ABC D Filter Fryer Fryer Dump Fryer ABC D Filter Dump Fryer Fryer Fryer AB C D Filter Fryer Fryer Fryer Fryer The configurations shown are standard (default) locations.
– 8 – FIELD-INSTALLED ACCESSORIES FACTORY-INSTALLED OPTIONS • Casters • Battery Non-Filter Ready Models Only • Twin Baskets • Battery Filter-In-A-Drawer Filtration • Tri-Baskets (65 and 85 models only) System • Single Baskets • Heat Lamp (RO only) • Flex Hose 4' (1.
– 9 – INST ALLA TION Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation.
– 10 – LOCATION (All Models) The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (15 cm) from the sides and 6" (15 cm) from the back of the fryer. Minimum clearance from noncombustible construction is 0" from the sides and 0" from the back.
– 11 – ASSEMBLY When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties.
– 12 – GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound must be resistant to the action of propane gases. The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.
– 13 – LEVELING FRYER (All Models) 1 . Place a level on top of the fryer after gas connections have been made. 2 . Adjust the legs to ensure that the fryer is level front to back and side to side in the final installed position. FLUE CONNECTIONS (All Models) The fryer must be located under a hood with adequate connection to an exhaust duct.
– 14 – -MAX- -MIN- PL-56390 Fig. 3 OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 15 – LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (Non-Filter Ready) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Turn the thermostat OFF. The thermostat is located behind the door (Fig.
– 16 – LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (Filter Ready Models, Fig. 6) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 200 250 300 4 OFF PILO T OFF ON PL-50293 Fig. 6 1 . Turn thermostat knob (located behind the door panel) to OFF.
– 17 – TURNING THE FRYER OFF 1 . Turn the thermostat OFF. 2 . To keep the pilot lit: For non-filter ready models, turn the gas control valve knob to "I" in PILOT. For filter-ready models, turn the valve arm to PILOT. 3 . To shut off all gas to the system, including the pilot, turn the gas control valve knob to OFF.
– 18 – SHORTENING LIFE (All Models) Shortening life can be extended by following these guidelines: • Do not salt foods over the fryer. • Use good-quality shortening. • Filter shortening daily (at a minimum). • Replace shortening if it becomes poorly flavored.
– 19 – Filter-Ready Models (Using Mobile Filter HMF50 or HMF85 Only) For filtering instructions of the filter-ready fryers, refer to the Installation and Operation Manual. This manual is supplied with each mobile filter system. Check tank vessel or accessory shipment box for manual.
– 20 – CLEANING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. DAILY Clean your fryer regularly with a damp cloth and polish with a soft dry cloth. If regular cleaning is neglected, grease will be burned on and discolorations may form.
Een belangrijk punt na aankoop van elk apparaat Hobart HG45F ML-135537 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart HG45F ML-135537 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart HG45F ML-135537 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart HG45F ML-135537 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart HG45F ML-135537 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart HG45F ML-135537 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart HG45F ML-135537 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart HG45F ML-135537 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.