Gebruiksaanwijzing /service van het product HGFD85 ML-126419 van de fabrikant Hobart
Ga naar pagina of 32
701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com HOBART HGF, HGD AND HGC SERIES GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-1.
– 2 – IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
– 3 – No. Model Size Tu be s BTU/Hr. Width Lbs. of Fry Compound 3 5 3 90,000 15 1/2" (39 cm) 35-40 (16-18 kg) 4 5 4 120,000 15 1/2" (39 cm) 45-50 (20-23 kg) 6 5 5 150,000 21" (53 cm.
– 4 – INSTALLATION Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation.
– 5 – ASSEMBLY When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties.
– 6 – GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound must be resistant to the reaction of propane gases. The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.
– 7 – FLUE CONNECTIONS The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must extend 6" (15 cm) beyond fryer sides.
– 8 – OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 9 – LIGHTING INSTRUCTIONS FOR HGF FRYER WITH MANUAL PILOT IGNITION CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Turn thermostat OFF. Thermostat is located behind the door (Fig. 5). 2 .
– 10 – HGFD & HGFC FRYER CONTROLS Gas Valve Extension Arm - Used to ignite and operate the pilot. LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (HGFD & HGFC SERIES) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening.
– 11 – STARTUP WITH ELECTRONIC IGNITION (HGFD & HGFC SERIES) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Plug the power cord into an appropriate grounded receptacle. 2 . Turn the main gas valve on.
– 12 – HGFD SERIES CONTROLS HGFD Series Fryers are equipped with digital controls and a solid state thermostat. Control Guide UP NOTE: For cleaning purposes when the fryer is filled with water. Temperature is automatically maintained at approximately 192°F (89°C).
– 13 – PROGRAMMING Temperature, time, energy source and other parameters must be set before operating. Once these parameters are set, the fryer can be operated at the touch of a button. Press to enter the program mode and scroll through the parameters.
– 14 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1 . Load the fry basket(s); do not overfill. See Recommended Basket Capacities section in this manual. 2 . Carefully lower basket(s) into shortening. 3 . Press to start the right timer.
– 15 – When the timer times out, a beeper sounds and the basket(s) automatically raise. Press to silence the left timer beeper. Press to silence the right timer beeper. 4 . For Single Basket Lifts: Press to lower the right basket. The timer begins counting down.
– 16 – HGFC SERIES CONTROLS HGFC Series Fryers have a microprocessor (computer) thermostat and timer. Control Guide Initiates program cooking cycles for units with or without basketlifts. For turning on or off the filter pump when supplied with built in filtering system.
– 17 – PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY Press SELECT OPTIONS Press DEGREES F or C F or C Press to select Fahrenheit or Celsius. DEGREES F or C F or C Press when complete. PROGRAM Press SELECT OPTIONS Press SET PASS NEW PASS Press to select NO PASS.
– 18 – Programming Guide (cont.) *Recovery - During a cold start, the controller measures the time the fryer takes to heat from 200°F to 250°F (93°C to 121°C) and compares it with factory default values. PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY Press SELECT OPTIONS Press ENGLISH (Factory Default) LANGUAGE Press to select a language.
– 19 – Melt Options When using solid shortening in the fryer, the SOLID melt option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening.
– 20 – TEMPERATURE AND TIME PROGRAMMING Temperature 1 . Press to enter program mode. PROGRAM is displayed in the window. 2 . Press to enter temperature mode. 000°F and TEMP are displayed in the window. 3 . Press through to enter desired fry temperature.
– 21 – Timers through : 1 . Press and enter the program mode. PROGRAM is displayed in the window. 2 . Press . The LED's on timers through are lit and SELECT PRODUCT is displayed in the window. 3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the window.
– 22 – Setting Advanced Time Features 1 . Press and enter the program mode. 2 . Press for timers through , or press for timers through . The LEDs are lit on the timers available for programming, and SELECT PRODUCT is displayed in the window. 3 . Select a timer; the programmed time is displayed in the window.
– 23 – Time Programming Quick Chart Press to enter the program mode Press for timers to Press for timers to Select a Timer Press to continue Set HOLD Time Select COMP or STRAIGHT Press Press Set D.
– 24 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1 . Load the fry basket(s); do not overfill. See Recommended Basket Capacities section in this manual. 2 . Carefully lower basket(s) into shortening. 3 . Press the desired program number to select the product to be timed.
– 25 – FRYING GUIDELINES (ALL MODELS) • Heat shortening to set temperature. • High Limit Device (All Models) - If the shortening becomes overheated, a high-temperature device will close the gas valve and extinguish the pilot. Should this occur, the pilot will be unable to relight until the shortening temperature is below 300°F (149°C).
– 26 – DAILY FILTERING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. Filtering Guidelines (All Models) • Stand alone fryers are available in filter-ready and non-filter-ready versions. • Battery interplumbing is available only on fryers equipped with Filter-In-A-Drawer.
– 27 – Battery Interplumbing (Available Only on Filter-In-A-Drawer Models) A battery of fryers equipped with optional interplumbing connects the fry tanks to a common drain. Each tank has an individual drain valve. Only one tank can be filtered at a time.
– 28 – CLEANING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. DAILY • Clean all exterior surfaces of your fryer at least once daily. • Use a damp cloth with warm water and a mild soap or detergent.
– 29 – 10. Drain the tank. 11. Rinse the tank thoroughly with clear, hot water (all traces of cleaner must be removed). 12. Dry the tank thoroughly. 13. Close the drain valve and add shortening. 14. Shortening level should be between the MIN and MAX lines.
– 30 – TROUBLESHOOTING GUIDE SYMPTOM No power when switch is turned on. Fryer will not heat. Fryer continues to heat. Fryer heats, but will not reach desired temperature. Fryer stops heating during operation. POSSIBLE CAUSES / SOLUTIONS Tripped breaker; fuse blown / Verify fryer is plugged in and outlet has power.
– 31 – ALARMS AND ERROR MESSAGES (HGD and HGC Series) Pilot Out - If the pilot is out, the control displays the following message: (Electronic ignition only) HGD Series - FIrE OUt HGC Series - PIL.
– 32 – FORM 35643 Rev. A (Apr. 2005) PRINTED IN U.S.A. NOTES.
Een belangrijk punt na aankoop van elk apparaat Hobart HGFD85 ML-126419 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart HGFD85 ML-126419 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart HGFD85 ML-126419 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart HGFD85 ML-126419 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart HGFD85 ML-126419 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart HGFD85 ML-126419 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart HGFD85 ML-126419 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart HGFD85 ML-126419 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.