701 S. RIDGE AVENUE TROY, OHIO 45374-0001 www.hobartcorp.com FORM 34709 (September 2001) N S T R U C T I O N S I MODEL HPGF15 GAS PRESSURE FR YERS ML-126825.
– 2 – © HOBART CORPORATION, 2001 IMPOR T ANT FOR Y OUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
– 3 – T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . .
– 4 – Installation, Operation and Care of MODEL HPGF15 GAS PRESSURE FR YERS SA VE THESE INSTR UCTIONS FOR FUTURE USE GENERAL Your Hobart Gas Pressure Fryer will produce a uniform, high-quality product time after time. It operates at a low temperature (325°F [163°C]) and high pressure (14 psi).
– 5 – LOCATION The equipment area must be kept free and clear of combustible substances. The pressure fryer, when installed, must have minimum clearance from combustible and noncombustible construction of 1" (2.5 cm) at the sides and 3" (7.
– 6 – Installing Casters Place the fryer on its side, being careful to avoid scratching the surface. Use only the casters supplied with your pressure fryer. Thread the four casters to the flanges on the bottom corners of the fryer. Use the open-ended wrench supplied to tighten (apply wrench at the flat surfaces on leg extensions) (Fig.
– 7 – Exhaust Pipe Thread the 1 1 / 4 " diameter exhaust pipe (supplied) to the top of the exhaust tank (Fig. 3) located at the rear of the fryer. Fig. 3 GAS CONNECTIONS All gas supply connections and any pipe joint compound used must be resistant to the action of liquified petroleum gases.
– 8 – TESTING THE GAS SUPPLY SYSTEM When test pressures exceed 1 / 2 psig (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system.
– 9 – Fig. 4 Fig. 5 PL-40936-1 EXHAUST VENT HAS BEEN REMOVED TO SHOW V AL VE CLEARL Y PL-40937-1 GAS V AL VE IN ON POSITION.
– 10 – 0 30 25 20 15 10 5 PL-52686 PRESSURE GAUGE OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 11 – FILLING THE KETTLE WITH LIQUID SHORTENING Oil Capacity: 40 lb/5 gal (18 kg/19 L). Use only a pure vegetable hydrogenated oil prescribed for use in pressure fryers, such as Mel Fry, Crystal, FryMax or Gold Label. Never add suet. Close drain valve (Fig.
– 12 – FRYING PROCEDURE FOR ALL FOODS Pressure is created by the containment of moisture escaping from the product being fried. Dry products that produce little or no moisture will not create sufficient pressure to fry that product. Pressure will not build without product in the kettle.
– 13 – 9. When pressure gauge reads 0, turn the handle counterclockwise until it stops before opening the lid. CAUTION: Seal damage can occur if handle is not completely unscrewed. Do not force the lid to open. ALWAYS swing the lid to the side. DO NOT raise the lid.
– 14 – PRESSURE-RELIEF VALVE The pressure-relief valve is located on the fryer lid. This relief valve is nonadjustable and preset at the factory to release the kettle pressure automatically if over 15 psi. This valve is also equipped with a ring (Fig.
– 15 – Other Items Which May Be Prepared in the Pressure Fryer TEMP. TIME FOOD (°F) (Min.) Chicken Fried Steak 325 8 Liver 325 4 Sweet Breads 325 4 Fish Fillets (Frozen & Prebreaded) 325 5 Sh.
– 16 – PL-40901 5. When clean, close drain valve and return oil to kettle. 6. Remove drain elbow. 7. Check oil level and turn fryer on. Cooking can resume when the white cooking light goes out. Filtering Oil at the End of the Production Day This procedure must be done while the kettle is still warm.
– 17 – Fig. 13 PL-41468-1 DIAPHRAGM Fig. 12 11. Continue with the cleaning instructions described in the CLEANING section of this manual. 12. Close drain valve and return oil to kettle. 13. Remove drain elbow. 14. Check oil level. The fryer is ready for the next production period.
– 18 – Cleaning After Every Production Period Exhaust Tank Drain the exhaust tank at the end of every production period while the liquid is hot. The exhaust tank drain valve is located behind the front access door at the lower right. 1. Attach drain pipe extension (supplied) and drain exhaust tank by turning drain valve handle up (Fig.
– 19 – Fig. 16 SOLENOID HEX NUT PRESSURE RELIEF PRESSURE REGLATOR HOUSING O-RING CLEAN-OUT PORT O-RING THUMB SCREW TEFLON GASKET (IINSIDE FITTING) PL-53523-E Fig.
– 20 – 5. The flexible diaphragm of the lid-locking device is visible when viewing the underside of the kettle lid. Make certain diaphragm material is not torn or punctured. If it is, contact your local Hobart service office for immediate replacement.
– 21 – Fig. 21 PL-40939-2 REMOVE BOL T Fig. 22 5. Remove 4 screws holding exhaust tank in place (see Fig. 21) and remove exhaust tank. 6. Flush exhaust tank with hot water. 7. Reverse procedure to reinstall exhaust tank. EXHA UST VENT 1-1/4" DIA.
– 22 – MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 23 – Cleaning Port Plug Screw The O-Ring seal on the cleaning port plug screw (Fig. 24) needs to be replaced if liquid is leaking around the screw. Fig. 24 VENT When fryer is off and cool, annually examine the flue and clear any obstructions. Contact personnel qualified to install and repair gas equipment for all other maintenance problems.
– 24 – POSSIBLE CAUSES 1. No product or very dry product loaded. 2. Power switch is in the OFF or FILTER position. 3. Lid not tightened. 4. Lid O-Ring not sealing. Replace O-Ring. 1. Dirty exhaust line to solenoid. 2. Dirty line from kettle pressure regulator to exhaust tank.
Een belangrijk punt na aankoop van elk apparaat Hobart HPGF15 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart HPGF15 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart HPGF15 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart HPGF15 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart HPGF15 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart HPGF15 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart HPGF15 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart HPGF15 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.