Gebruiksaanwijzing /service van het product SR24C van de fabrikant Hobart
Ga naar pagina of 16
FORM 35309 Rev. B (Jan. 2006) MODEL SR24 SERIES DISHW ASHERS MODELS SR24C ML-130021 SR24H ML-130022 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.
– 2 – © HOBART CORPORATION, 2006 T ABLE OF CONTENTS General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 In st al la ti on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 3 – Installation, Operation and Care of MODEL SR24 SERIES DISHW ASHERS SA VE THESE INSTRUCTIONS GENERAL The SR24 Series Dishwashers are fully automatic, front-loading machines that are equipped with a 1 / 2 H.
– 4 – LOCATION Prior to installation, test the electrical service to make sure that it agrees with the specifications on the machine data plate, located on the top of the door. Place the machine in its operating location. Before any connections are made, the machine must be level.
– 5 – Minimum Maximum Machine Type & Rated Supply CKT Overcurrent Specification AMPS Conductor Protective Ampacity Device SR24C 120/60/1 9 15 15 SR24H 120/240 (3W)/60/1 37.6 50 50 * or 120/208 (3W)/60/1 42.0 50 50 * * These are 3-wire systems that require (3) #8 AWG copper wires (90 ° C) including a current carrying neutral.
– 6 – MODELS SR24C AND SR24H WITH PANELS 23 7 / 8 " Top Panel 1 3 / 16 " 23 15 / 16 " Top Panel Overall Height With Top Panel 35 13 / 16 " min. 36 13 / 16 " max. WARNING : NOT RECOMMENDED FOR INSTALLATION WITHIN WOODEN, PLYWOOD OR OTHER SIMILAR, NONMOISTURE-RESISTANT FRAMEWORK.
– 7 – PLUMBING CONNECTIONS WARNING : PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. WATER SUPPLY The water supply must be within the recommended hardness range of 4 to 6 grains per gallon. Lower hardness can cause corrosion; higher hardness can cause formation of lime scale.
– 8 – ELECTRICAL CONNECTIONS WARNING : ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING : DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.
– 9 – INITIAL FILLING (MODEL SR24H ONLY) After electrical and plumbing connections have been made make sure the water service valve is open and add a cup of water to the sump to help lubricate the seal. Close the door and turn the On-Off switch (Fig.
– 10 – OPERA TION Caution: Items such as pewter, aluminum and silver are attacked by sodium hypochlorite (bleach). Therefore, the Model SR24C Chemical Sanitizing unit should not be used to wash such items. PREPARATION Check to make sure that the strainer is in place and free of debris.
– 11 – Use only commercial-grade detergents recommended by your chemical professional. Do not use detergents formulated for residential dishwashers. Chemical dispensing pumps (if so equipped) are factory set to provide proper concentration of each chemical.
– 12 – CLEANING This machine must be cleaned at least once each working day. 1. Turn the On-Off switch to the off position (Figs. 2 and 3 on page 10). 2. Open the door and remove the wash arms and the strainer assembly (Fig.5). 3. To remove the lower wash arm, remove the retaining screw (Fig.
– 13 – MAINTENANCE DELIMING The dishwasher should be delimed on a regular basis as required. The frequency will depend on the mineral content of the supply water. Inspect the machine interior for lime deposits. If deliming is necessary, a deliming agent (such as Lime Away or LSR) should be used for best results.
– 14 – DELIMING MODEL SR24H (HOT WATER SANITIZING MODEL) Delime as follows: 1. Remove rack from machine. 2. Close the door. 3. Allow machine to fill for 10 to 15 seconds. 4. Partially open the door and wait 5 seconds. 5. Open door; add deliming agent (carefully follow supplier's instructions).
– 15 – TROUBLESHOOTING This section outlines various symptoms and possible causes that may be encountered if abnormal machine operation occurs. If symptoms persist after possible causes have been checked, service may be required. SYMPTOM POSSIBLE CAUSE Machine does not operate.
– 16 – CHEMICAL SENSING MODULE — OPERATION AND START-UP Operate the chemical dispensing pumps (refer to page 11) to make sure that liquid chemical is present in the tubing going through the sensors in the chemical sensing module.
Een belangrijk punt na aankoop van elk apparaat Hobart SR24C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart SR24C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart SR24C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart SR24C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart SR24C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart SR24C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart SR24C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart SR24C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.