Gebruiksaanwijzing /service van het product CHAMP 2060 van de fabrikant Hobart Welding Products
Ga naar pagina of 60
Processes Description Stick (SMAW ) W elding Engine Driven Welding Generator OM-499 197 850G June 2003 Visit our website at www.HobartWelders.com CHAMP 2060.
Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1.
The following terms are used interchangeably throughout this manual: TIG = GT AW Stick = SMAW MIG = GMAW The engine exhaust from this product contains chemicals known to the State of California to cause cancer , birth defects, or other reproductive harm.
.
OM-499 Page 1 SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING rom _nd_10/02 W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-499 Page 2 BUILDUP OF GAS can injure or kill. Shut off shielding gas supply when not in use. Always ventilate confined spaces or use approved air-supplied respirator . Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-499 Page 3 MOVING P ARTS can cause injury . Keep away from fans, belts, and rotors. Keep all doors, panels, covers, and guards closed and securely in place. Stop engine before installing or connecting unit. Have only qualified people remove guards or covers for maint- enance and troubleshooting as necessary .
OM-499 Page 4 FL YING SP ARKS can cause injury . W ear a face shield to protect eyes and face. Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection. Sparks can cause fires — keep flammables away .
OM-499 Page 5 SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE A V ANT UTILISA TION rom_10_02fre A vertissement: Protégez vous et les autres des blessures – lisez et suivez ces précautions.
OM-499 Page 6 LES ACCUMULA TIONS DE GAZ ris- quent de provoquer des blessures ou même la mort. Fermer l’alimentation du gaz protecteur en cas de non utilisation. V eiller toujours à bien aérer les espaces confinés ou se servir d’un respi- rateur d’adduction d’air homologué.
OM-499 Page 7 L ’EXPLOSION DE L A B A TTERIE peut RENDRE A VEUGLE. T oujours porter une protection faciale, des gants en caoutchouc et vêtements de protection lors d’une in- tervention sur la batterie. Arrêter le moteur avant de débrancher ou de brancher les câbles de batterie.
OM-499 Page 8 LE SURCHAUFFEMENT peut endom- mager le moteur électrique. Arrêter ou déconnecter l’équipement avant de dé- marrer ou d’arrêter le moteur . Ne pas laisser tourner le moteur trop lentement sous risque d’endommager le moteur électrique à cause d’une tension et d’une fréquence trop faibles.
OM-499 Page 9 SECTION 2 – DEFINITIONS 2-1. Symbol Definitions Engine Choke Read Operator’s Manual A Amperes V V olts Engine Oil Fuel Battery (Engine) Engine Positive Negative Alternating Current (.
OM-499 Page 10 3-2. Dimensions, W eights, And Operating Angles Dimensions Height 20-3/4 in (527 mm) D Width 22-3/4 in (577 mm) D Depth 31-1/4 in (793 mm) B Do not exceed tilt angles or engine could be damaged or unit could tip. A 31-1/4 in (793 mm) B be damaged or unit could tip.
OM-499 Page 1 1 3-4. Fuel Consumption (Honda-Powered Units) 802 122 Continuous Welding 3-5. Duty Cycle 802 093 Duty cycle is the percentage of 10 minutes that unit can weld at rated load without overheating. Exceeding duty cycle can damage unit and void warranty .
OM-499 Page 12 3-6. Generator Power Curves 198 570 The generator power curves show the ac power available in amperes at the receptacles. A. 60 Hz Model B.
OM-499 Page 13 3-7. V olt-Ampere Curves 198 570 The volt-ampere curve shows the minimum and maximum voltage an d amperage output capabilities o f th e welding generator .
OM-499 Page 14 SECTION 4 – INST ALLA TION 4-1. Installing Welding Generator install1 10/00*– 802 524-A / Ref. 151 556 / 158 936-A / S-0854 18 in (460 mm) 18 in (460 mm) 18 in (460 mm) 18 in (460 m.
OM-499 Page 15 4-3. Grounding Generator When Supplying Building Systems GND/PE 1 2 Use ground device as stated in electrical codes. 2 3 800 576-B 1 Equipment Grounding T erminal 2 Grounding Cable Use #10 A WG or larger insulated copper wire.
OM-499 Page 16 4 -5. Engine Prestart Checks (Honda-Powered Units) 802 094-A Full Full Gasoline 1/2 i n (13 mm) 1 Check all fluids daily . Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil. Engine stops if oil level gets too low .
OM-499 Page 17 4-7. Connecting T o Weld Output T erminals 196 914 / 495 178 1 Positive (+) W eld Output T erminal 2 Negative (–) Weld Output T erminal For Direct Current Electrode Posi - tive (DCEP), connect work cable to Negative (–) terminal and electrode holder to Positive (+) terminal.
OM-499 Page 18 SECTION 5 – OPERA TING THE WELDING GENERA TOR 5-1. Controls (Kohler-Powered Units) 802 51 1-A / 802 051 1 / 495 178 6 7 60 Hz Weld and generator power output stops i f generator overheats or engine speed is too low . 1 Engine Switch Us e switch to open ignition circuit, and to stop engine.
OM-499 Page 19 5-2. Controls (Honda-Powered Units) (See Section 5-3) 802 094-A / 802 095 / 495 187 Recoil-Start Electric-Start 60 Hz 50 Hz 1 3 6 2 1 4 5 7.
OM-499 Page 20 5-3. Description Of Controls (Honda-Powered Units) (See Section 5-2) Weld and generator power output stops i f generator overheats or engine speed is too low . 1 Engine Switch On models with recoil-start, use switch to open ignition circuit, and to stop engine.
OM-499 Page 21 SECTION 6 – OPERA TING AUXILIAR Y EQUIPMENT The welding generator provides power while welding and with the Current control in any position. However , under these conditions equipment connected to the welding generator may be subject to larger than normal voltage fluctuations.
OM-499 Page 22 6-2. Optional Generator Power Panels Ref. ST-802 124 / H-495 290 / H-495 283 / 495 277 Generator Power Panel 495 315 (USA) Generator Power Panel 495 278 (Canada–CSA) Generator Power P.
OM-499 Page 23 6-3. Generator Power Panel Ratings Unless otherwise stated, the rating of duplex outlets is the combined load of all receptacles. NOTE T otal power from generator NOT to exceed 5500 W a.
OM-499 Page 24 6-4. Wiring Instructions For Optional 120/240 V olt T wistlock Plug (NEMA L14-30P) plug3-1 1/99 – 802 527 1 Plug Wired For 120/240 V , 3-Wire Load When wired for 120 V loads, each d u - plex receptacle shares a load with one half of the 240 V receptacle.
OM-499 Page 25 7-2. Routine Maintenance Recycle engine fluids. Stop engine before maintaining. Se e Engine Manual and Maintenance Label. Ser- vice more often if used in severe conditions. * T o be done by Factory Authorized Service Agent. 8 h 20 h Wipe up spills.
OM-499 Page 26 7-3. Overload Protection (Honda-Powered Units) 1 Ignition Circuit Breaker (Electric-Start Models Only) The circuit breaker protects the en- gine battery charging circuit. A short circuit or a battery connected in reverse polarity will trip the circuit breaker .
OM-499 Page 27 7-5. Adjusting Engine Speed (Honda-Powered Units) 802 097-A After tuning engine, check engine speeds. See table for proper no load speeds. If necessary , adjust speeds as follows: Start engine and run until warm. W eld/Power Speed Adjustment 1 Throttle Control Lever 2 Adjustment Screw Move lever to Run (60 Hz) position.
OM-499 Page 28 SECTION 8 – TROUBLESHOOTING 8-1. T roubleshooting A. Welding T rouble Remedy No weld output. Check Amperage control setting. Check weld connections. Check engine speed, and adjust if necessary (see Section 7-4 or 7-5). Output stops if engine speed is too low .
OM-499 Page 29 T rouble Remedy Lo w power output at generator power ac receptacles. Check Amperage control setting. Check engine speed, and adjust if necessary (see Section 7-4 or 7-5). Output stops if engine speed is too low . Move throttle lever to 60 Hz position for 60 Hz equipment (see Section 5-1 or 5-2).
OM-499 Page 30 SECTION 9 – ELECTRICAL DIAGRAMS 197 857-E Figure 9-1. Circuit Diagram For Welding Generator (1 Of 2).
OM-499 Page 31 197 857-E Figure 9-2. Circuit Diagram For Welding Generator (2 Of 2).
OM-499 Page 32 197 858-C Figure 9-3. Wiring Diagram For Welding Generator.
OM-499 Page 33 201 026-A Figure 9-4. Wiring Diagram For Auxiliary Power Panels (1 Of 2).
OM-499 Page 34 201 026-A Figure 9-5. Wiring Diagram For Auxiliary Power Panels (2 Of 2).
OM-499 Page 35 SECTION 10 – GENERA TOR POWER GUIDELINES The views in this section are intended to be representative of all engine-driven welding generators. Y our unit may differ from those shown. NOTE 10-1. Selecting Equipment gen_pwr 1 1/02 – Ref.
OM-499 Page 36 10-3. Grounding When Supplying Building Systems ST-800 576-B 1 Equipment Grounding T erminal 2 Grounding Cable Use #10 A WG or larger insulated copper wire. 3 Ground Device Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system.
OM-499 Page 37 10-5. Approximate Power Requirements For Industrial Motors Industrial Motors Rating Starting W atts Running W atts Split Phase 1/8 HP 800 300 1/6 HP 1225 500 1/4 HP 1600 600 1/3 HP 2100.
OM-499 Page 38 10-7. Approximate Power Requirements For Contractor Equipment Contractor Rating Starting W atts Running W atts Hand Drill 1/4 in 350 350 3/8 in 400 400 1/2 in 600 600 Circular Saw 6-1/2.
OM-499 Page 39 10-8. Power Required T o Start Motor S-0624 1 Motor Start Code 2 Running Amperage 3 Motor HP 4 Motor V oltage T o find starting amperage: Step 1: Find code and use table to find kV A/HP . If code is not listed, multiply running amperage by six to find starting amperage.
OM-499 Page 40 10-10. T ypical Connections T o Supply Standby Power Have only qualified persons perform these connections according to all applicable codes and safety practic- es. Properly install and ground this equipment according to its Owner ’ s Manual and national, state, and local codes.
OM-499 Page 41 10-1 1. Selecting Extension Cord (Use Shortest Cord Possible) Cord Lengths for 120 V olt Loads If unit does not have GFCI receptacles, use GFCI-protected extension cord.
OM-499 Page 42 SECTION 1 1 – STICK WELDING (SMA W) GUIDELINES 1 1-1. Stick Welding Procedure stick 12/96 – ST-151 593 W eld current starts when electrode touches work- piece. W eld current can damage electronic parts in vehicles. Disconnect both battery cables before welding on a vehicle.
OM-499 Page 43 1 1-2. Electrode and Amperage Selection Chart Ref. S-087 985-A 3/32 1/8 5/32 3/16 7/32 1/4 1/16 5/64 3/32 1/8 5/32 3/16 7/32 1/4 3/32 1/8 5/32 3/16 7/32 1/4 3/32 1/8 5/32 3/16 7/32 1/4 .
OM-499 Page 44 1 1-5. Positioning Electrode Holder S-0060 90 ° 90 ° 10 ° -30 ° 45 ° 45 ° GROOVE WELDS FILLET WELDS End View of W ork Angle Side V iew of Electrode Angle End View of W ork Angle Side V iew of Electrode Angle 10 ° -30 ° 1 1-6.
OM-499 Page 45 1 1-8. Conditions That Affect Weld Bead Shape Weld bead shape is affected by electrode angle, arc length, travel speed, and thickness of base metal. NOTE S-0061 ELECTRODE ANGLE ARC LENGTH TRA VEL SPEED Slow Normal Fast 10 ° - 30 ° Drag T oo Short Normal T oo Long Spatter Angle T oo S mall Angle T oo Large Correc t Angle 1 1-9.
OM-499 Page 46 1 1-10. Butt Joints S-0662 1 T ack Welds Prevent edges of joint from drawing together ahead of electrode by tack welding the materials in position be- fore final weld. 2 Square Groove Weld Good for materials up to 3/16 in (5 mm) thick. 3 Single V -Groove Weld Good for materials 3/16 – 3/4 in (5-19 mm) thick.
OM-499 Page 47 1 1-13. Weld T est S-0057-B 1 V ise 2 W eld Joint 3 Hammer Strike weld joint in direction shown. A good weld bends over but does not break. 2 T o 3 in 1/4 in 3 2 1 2 T o 3 in 3 2 1 (51-76 mm) (6.4 mm) (51-76 mm) 1 1-14. T roubleshooting – Porosity Porosity – small cavities or holes resulting from gas pockets i n weld metal.
OM-499 Page 48 1 1-16. T roubleshooting – Incomplete Fusion Incomplete Fusion – failure of weld metal to fuse completely with base metal or a preceeding weld bead. Possible Causes Corrective Actions Insuf ficient heat input. Increase amperage. Select larger electrode and increase amperage.
OM-499 Page 49 1 1-19. T roubleshooting – Burn-Through Burn-Through – weld metal melting completely through base metal resulting in holes where no metal remains. Possible Causes Corrective Actions Excessive heat input. Select lower amperage. Use smaller electrode.
OM-499 Page 50 SECTION 12 – P ARTS LIST 802 509-A Hardware is common and not available unless listed. 7 32 33 34 31 28 29 30 24 23 46 40 41 44 42 43 36 38 39 37 35 47 48 8 6 5 4 9 10 11 2 1 27 18 25 26 22 20 21 19 15 17 16 14 13 12 45 3 49 50 Figure 12-1.
OM-499 Page 51 Description Part No. Dia. Mkgs. Item No. Figure 12-1. Main Assembly Quanti ty 1 +495 247 TOP , control box (specify color) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 495 096 LABEL, precautionary 1 .
OM-499 Page 52 Description Part No. Dia. Mkgs. Item No. Figure 12-1. Main Assembly (Continued) Quanti ty 41 1T 172 661 BLOCK, terminal 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-499 Page 53 Hardware is common and not available unless listed. Generator Power Panel 495 315 (USA) Generator Power Panel 495 219 (USA) Generator Power Panel 495 278 (Canada–CSA) Generator Po.
OM-499 Page 54 Description Part No. Dia. Mkgs. Item No. Figure 12-2. Generator Power Panels (Figure 12-1, Item 39) Quanti ty Generator Power Panel 495 218 (USA) 1 495 220 P ANEL, generator power assembly 1 . . . . . . . . . . . . . . . . . . . . . . .
Warranty Questions? Call 1-877-HOBART1 for your local Hobart distributor. hobart retail 6/02 Service Y o u always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281.
PRINTED IN USA 2003 Hobart Welding Products. 1/03 Hoba rt We lding Product s An I l li noi s T ool Works Company 600 W es t Main St reet Troy , OH 45373 U SA For T echn i cal A ssistance: Call1-80.
Een belangrijk punt na aankoop van elk apparaat Hobart Welding Products CHAMP 2060 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart Welding Products CHAMP 2060 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart Welding Products CHAMP 2060 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart Welding Products CHAMP 2060 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart Welding Products CHAMP 2060 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart Welding Products CHAMP 2060 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart Welding Products CHAMP 2060 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart Welding Products CHAMP 2060 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.