Gebruiksaanwijzing /service van het product CT3600 van de fabrikant Honeywell
Ga naar pagina of 24
69-1642 OWNER’S GUIDE ® U.S. Registered Trademark Copyright © 2002 Honeywell • •All Rights Reserved Honeywell CT3600/CT3697 PROGRAMMABLE THERMOSTAT Seven Day Programmable Heat and/or Cool Low .
69-1642 2 Total comfort temperature mana gement with Smart Response™ Technology. Congratulations! Y ou made a smart choice by purchasing your new Honeywell thermostat; the smart thermostat that; •.
3 69-1642 Time Set Program Run Program Hold Temp Set Current Day/Time Day Heat/Cool Settings Daylight Time Copy Usage System Fan Wake Leave Return Sleep Heat Off Cool On Auto M18635C RAISES TEMPERATUR.
69-1642 4 M16421C Aux Ht System Off Auto WakeLeaveReturnSleep Mon Wait In Room Humid Outdoor Filter AM Hold for Repl Batt Recovery Cool Tue WedThu FriSatSun Days Set Program Set Day/Time Temporary Set.
5 69-1642 STEP 1. PREPARE FOR INSTALLATION ❑ Check T able 1, the compatibility chart, to make sure t he t hermostat is compatible with your system. If your system is not compatible, call Honeywell Custom er Relations Center , toll-free, 1-800-468-1502.
69-1642 6 STEP 2. REMOVE OLD THERMOSTAT ❑ T est your heating and cooling systems to make sure they wor k properly . If either system does not wor k, contact your local heating/air-conditioning dealer . T o avoid compressor damage, do not operate th e cooling system when outdoor temperature is below 50°F (10°C).
7 69-1642 STEP 3. MOUNT THERMOSTAT WALLPLATE ❑ Separate the wallplate from the thermostat by placing your thumb or fingers between the bottom of the wallplate and the thermostat, and pulling the wallplate up and away from the thermostat. See illustration at right.
69-1642 8 STEP 4. WIRE WALLPLATE TERMINALS IMPORT ANT All wiring must comply with local codes and ordinances. If unsure about household wiring proc edur es, call your local heat- ing/air-conditioning contractor. Refer to the labels you placed on t he wires wh en you removed the old thermostat (see illustration).
9 69-1642 T able 2. T erminal Designations on Old and New Thermostat s a If both RH and R terminals are present on existing ther most at, remove jumper and connect Rh to R and R to Rc. b Do not connect both O and B when wiring to a single stage heat pump.
69-1642 10 When the batteries are running low, a REPL BA T message flashes for one to two months before the batteries run out completely . R eplace the batteries as soon as possible once the message flashes.
1 1 69-1642 STEP 7. MOUNT THE THERMOSTAT STEP 8. CUSTOMIZE YOUR THERMOSTAT Y ou r Honeywell CT3600/CT3697 Thermostat comes preset to the most commonly used settings. The settings are: — Gas or oil forced air furnace. — Smart Response technology on.
69-1642 12 — 3 = Hot water , high efficiency furnace (90% or better), or single stage heat pump. — 6 = Gas or oil forced air furnace (p reset). — 9 = Electric furnace. T o change you r system type: ❑ Press until display shows your furnace or boiler type.
13 69-1642 T o change time f ormat: ❑ Press once. ❑ Press to return to main display . Factory Set Function (Feature Number 37) Do not change this setting. STEP 9. SET THE CLOCK Set Current Da y and Time NOTE: On initial power-up, the screen flash es 1:00 pm until you press a key .
69-1642 14 STEP 10. PROGRAMMING The keyboard is located behind the thermostat cover . T he three most frequently used keys are ne ar the display . Pressing displays the current temperature settings. Pressing the and keys change the temperature. T he thermostat displays day , time, program period, temperatur e and system settings.
15 69-1642 T able 3 can be helpful when planning your schedule of time and temperature settings. The thermostat default settings are shown in parentheses ( ). T able 3. Personal Programm ing T able. a Y our heating setpoints cannot be higher than 90°F (32°C) or lower than 4 0°F (4.
69-1642 16 NOTE: Program times are in 15 minu te in tervals. For example, 8:00, 8:15, 8:30. ❑ Press or until the desired wake te mperature displays. The setpoint temperature range is 40°F to 90°F (4 .5°C to 32°C) for heating and 45°F to 99°F (7° C to 37°C) for cooling.
17 69-1642 ❑ Press until the display sh ows the day you want to copy to. ❑ Press to accept the change . ❑ Repeat these steps for each day you want to copy . NOTE: donE appears for two seconds and then the normal program display appears. Clear a Program Period NOTE: W ake canno t be cleared.
69-1642 18 Change Temperature Setti ng Indefinitely (Hold) ❑ Move the System switch to the desired position (Heat or Cool). ❑ Press then or to change your setting if desired. (The disp lay chang es from showing the setpoint temperature to room temperature after app roximately three seconds).
19 69-1642 Usage Key ❑ Press once to display the hours and minutes that the heating or cooling system has been operating for the current day . ❑ Press a second time to display the system ope rati ng time for the previous day (midnight to midnight).
69-1642 20 IF YOU HAVE A PROBLEM T able 4. Solution Guide. If... Then… Display does not appear . • Make sure the batteries are installed correctly . • Make sure the thermostat is mounted and latched on the wallplate. Mount and latch the thermostat on the wallplate if it is not.
21 69-1642 Customer Assistance Please read and follow the provided instructions for this the rmostat. For additional information, go to www .honeywell.com/yourhome or call our 24-hour au tomated information line at 1-800-468-1502. Before calling, please have the following information available : • Thermostat model number .
69-1642 22 WIRING DIAGRAMS THERMOSTAT 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1 HEATING RELAY OR VALVE COIL B R RC OW Y G 2-WIRE HEAT-ONLY (JUMPER INTACT) M1061 6 M1061 7 THERMOSTAT 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
23 69-1642 Notice: This thermostat is a Class B digita l app aratus that complies with C anadian Radio Interference Regulations, CRC c. 1374. M1061 9 THERMOSTAT 1 POWER SUPPLY.
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. 69-1642 G .H. 7- 02 www .honeywell.com/yourhome Automation and Control Solutions Honeywell Honeywell Lim ited-Ho.
Een belangrijk punt na aankoop van elk apparaat Honeywell CT3600 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honeywell CT3600 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honeywell CT3600 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honeywell CT3600 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honeywell CT3600 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honeywell CT3600 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honeywell CT3600 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honeywell CT3600 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.