Industrial Automation and Control, 110 Virginia Drive, Fort Washington, PA 19034 Printed in U.S.A. ■ Copyright 1997 Honeywell Inc. UDC3000 Versa-Pro Universal Digital Controller 51-52-03-07 2/97.
51-52-03-07 Page 2 Features, continued CE Mark- Conformity with 73/23/EEC, Low Voltage Directive and 89/336/EEC, the EMC Directive Moisture Resistant Front Panel - Capable of meeting NEMA 3 and IEC529 IP65 (i.e. hosedown) requirements. Timer - This standard feature pro- vides a configurable time period of 0 to 99 hours, 59 minutes.
51-52-03-07 Page 3 Output Types The following output types are available per the model selection guide: • Current output • Electromechanical relays • Solid state relays • Open collector output.
51-52-03-07 Page 4 ALM RSP OUT % 1 2 1 2 1 2 F C MAN FUNCTION SET UP LOWER DISPLAY MANUAL AUTO SETPOINT SELECT RUN HOLD DI Indicator definition when lit ALM - Alarm conditions exist DI - Digital Input.
51-52-03-07 Page 5 Specifications Design CE Conformity (Europe) This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC , the Low Voltage Directive, and 89/336/EEC , the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed.
51-52-03-07 Page 6 Specifications (continued) Design (continued) Controller Output Types Current Output (Isolated) Range can be set anywhere between 0 to 21 mA, and as direct or reverse action. Resolution: 11 bits for 0 to 21 mA Accuracy: 0.5% full scale Temperature Stability: 0.
51-52-03-07 Page 7 Specifications (continued) Design (continued) Auxiliary Linear Output (Optional) (Isolated) 21 mA dc maximum into a negative or positive grounded load or non-grounded load of 0 to 1000 ohms. Output range can be set anywhere between 0 to 21 mA, and as direct or reverse action.
51-52-03-07 Page 8 Specifications (continued) Environmental and Operating Conditions Parameter Reference Rated Operative Limits Transportation and storage Ambient Temperature 25 ± 3 ˚ C 77 ± 5 ˚ F.
51-52-03-07 Page 9 General Reference Data Data Isolation (Functional) AC Power : is electrically isolated from all other inputs and outputs to withstand a HIPOT potential of 1900Vdc for 2 seconds per Annex K of EN61010-1. Analog Inputs and Outputs: are isolated from each other and all other circuits at 850Vdc for 2 seconds.
51-52-03-07 Page 10 Dimensions Panel Cutout ALM RSP OUT % 1 2 1 2 F C MAN PV 1 2 3 4 96 3.780 AL M % 1 2 1 2 1 2 F C M A N DI ALM RSP OUT % 1 2 1 2 F C MAN DI FUNCTION LOWER DISPLAY MANUAL AUTO SETPOINT SELECT SET UP HOLD 1 2 24 .945 Max Panel Thickness 10 .
51-52-03-07 Page 11 Wiring Diagram 1 2 3 4 5 6 7 8 9 ALM 1 CTL 2 ALM 2 CTL 1 4-20 MA 10 11 12 13 14 15 16 17 DI 1 TX- or AUX- TX+ or AUX+ RX-/TX- RX+/TX+ SHIELD DI 2 UDC 3000 EXTERNAL WIRING L1/H L2/N.
51-52-03-07 Page 12 Ordering Information For the complete ordering information, request Model Selection Guide: 51-51-16-32 for UDC3000 Universal Digital Controller or . . Honeywell offers a full Iine of Sensors, Transmitters, and Final Control Devices for use with the UDC3000 Universal Digital Controller.
Een belangrijk punt na aankoop van elk apparaat Honeywell DC300K-E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honeywell DC300K-E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honeywell DC300K-E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honeywell DC300K-E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honeywell DC300K-E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honeywell DC300K-E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honeywell DC300K-E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honeywell DC300K-E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.