Gebruiksaanwijzing /service van het product SERIES 2000 van de fabrikant Honeywell
Ga naar pagina of 20
1 63-4356—1 Series 2000 Commercial Microelectronic Thermostat ® U.S. Registered T rademark Copyright © 1996 Honeywell Inc. • All Rights Reserved Contents Features .................................................................. 3 Programming .
63-4356—1 2 Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied Start Time Run Program Temporary Occupied Continuous Unoccupied Set Current .
3 63-4356—1 FEA TURES •P r ogram up to tw o Occupied and two Unoccupied time periods f or each daily schedule. • Set different schedules f or each day of the week.
63-4356—1 4 PROGRAMMING The keyboard is located behind the thermostat cover . Sixteen keys are used to set, review and modify programmed times and temperature settings.
5 63-4356—1 Day Occupied Period 1 Unoccupied Period 1 Occupied Period 2 Unoccupied Period 2 Monday Tuesday Wednesday Thursday Friday Saturday Sunday.
63-4356—1 6 The program has four temperature settings, Occupied and Unoccupied heat and cool. The thermostat will operate at the Unoccupied temperature setting unless the thermostat is programmed. The following chart shows the default temperature settings.
7 63-4356—1 Press Day until the current day is displayed. NOTE: Sun = Sunday , Mon = Monday , T ue = T uesday , Wed = Wednesday , Thu = Thursday , Fri = Friday , Sat = Saturday .
63-4356—1 8 Press Day until the desired day is displayed. AM Wed Occupied 1 Set Program Start Time M4956A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day Sys.
9 63-4356—1 Press increase ▲ or decrease ▼ key until the desired start time is displayed. Un PM Wed Occupied 1 Set Program Start Time M4961A Set Program Set Temperature Change Time/Temp Occu.
63-4356—1 10 Press Day to select the day to be copied if different from the day displayed. M4966A Set Program Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day.
11 63-4356—1 Repeat steps through for all the days desired. Press Run Program. M4954A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan .
63-4356—1 12 Press Heat/Cool Settings to change between heat and cool settings. Cool Occupied Setting M4972A Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day .
13 63-4356—1 Press Heat/Cool Settings to change between heat and cool settings. Un Cool Setting Occupied M4976B Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time D.
63-4356—1 14 Press Clear Start T ime. Occupied 1 Set Program Start Time M4979B Mon Set Program Set Temperature Change Time/Temp Occupied Temp Unoccupied Start Time Day System Fan Copy Occupied S.
15 63-4356—1 Press increase ▲ or decrease ▼ key until the desired temperature offset is displayed (range is 0 ° to 5 ° F). M4981A Set Program Set Temperature Change Time/Temp Occupied Temp.
63-4356—1 16 NOTE: If the of fset is zero, the default setting changes in one degree incre- ments. If the offset is 1 through 5, the default setting changes by plus or minus the offset.
17 63-4356—1 Press Heat/Cool Setpoint to change between heat and cool settings. Use increase ▲ or decrease ▼ key to adjust temperature settings.
63-4356—1 18 TROUBLESHOOTING GUIDE Symptom Action Display will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to the On position.
19 63-4356—1 TROUBLESHOOTING GUIDE (Continued) Symptom Action Cooling will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to On position.
63-4356—1 20 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422-4386 63-4356—1 J.H. Rev. 12-96 20 www .honeywell.
Een belangrijk punt na aankoop van elk apparaat Honeywell SERIES 2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honeywell SERIES 2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honeywell SERIES 2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honeywell SERIES 2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honeywell SERIES 2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honeywell SERIES 2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honeywell SERIES 2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honeywell SERIES 2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.