Gebruiksaanwijzing /service van het product TB7200 van de fabrikant Honeywell
Ga naar pagina of 28
INTEGRATION MANUAL Put Bar Code Here 63-4524-01 BACnet Integration Manual for TB7200 & TB7300 Series Thermost at s TB7200 Series Thermostat TB7300 Series Thermostat with Occupanc y Sensor Contents Product Overview ............ ........... ........
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 2 COMP ATIBILITY Honeywell TB7200 and TB7300 Series the rmostat compatiblity information is p rovided in T able 1. T able 1. TB7200 Series and TB7300 Series Thermostat Comp atib ility Information * 128 total devices supported.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 3 63-4524—01 • T o assign a Room T emperature (A V7) value ma nually , users must first enable the Override mode in the Room T emp Override (BV8) object.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 4 Cable T ype Honeywell recommends the use of balan ced 22-24 AWG twist ed pair with a characteristic imp edance of 100-130 ohms, capacitance of 30 pF/f t or lower . A braided shield is also recommended .
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 5 63-4524—01 NETWORK CONFIGURATION EIA-485 networks use a daisy chain configurat i on. A daisy chain means that there is only o ne main cable and every network device is connected directly along its path.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 6 Maximum Cable Length The maximum length of a chain is related to its transmission speed . The lon ger the chain, the sl owe r the speed. Using proper cable, the maximum length of an EIA-485 daisy cha in is 4000-ft (1200 m).
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 7 63-4524—01 End Of Line (EOL) Resistors MS/TP network must be prop erly terminated. Fo r daisy chain configu rations, you must inst all an EOL resistor at each end of the daisy chain.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 8 NETWORK ADAPTER The polarity of the connection to the cable is impo rtant. From one module to th e other it is important that the same colored wi re be connected to “pl us” or “+” and the o ther colored wire b e c onnected to the “minus” or ”-“.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 9 63-4524—01 INTEGRATION Global Commands The following figure shows which objects from the thermostat can be monitored and commande d from the BAS front-end. Fig. 6. Global commands from a BAS fron t-e nd to a typical TB7300 Series thermostat.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 10 TB7200 Integration – Graphical User Interface (GUI) object s The following objects sho uld be typically used in .
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 11 63-4524—01 TB7300 Integration – Graphical User Interface (GUI) Object s The following objects should be typically used in a.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 12 Configuration Object s The following objects and group objects should be typically used for configu ration purpose.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 13 63-4524—01 Graphical interfaces For example, some graphic interface mig ht poll every data linked to the graphic page on a COV basi s.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 14 T ROUBLESHOOTING Error / Tr ouble Condition Possible Cause Solution Thermostat does not come online Two or more control lers have the same MAC address. Modify each duplicate address to a unique number.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 15 63-4524—01 APPENDIX TB7200 & TB7300 Series Protocol Im plement ation Conf ormance St atement (PICS) V endor Name: Honeywe.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 16 BACNET OBJECTS SUPPORTED Device Object s T able 4. Device Object s. Object Name Type and Instance Object Property Thermostat Parameter TB7200X5x14B TB73xxX5X14B Device Object_Identifier Property 75 (R,W) Unique ID number of a device on a network.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 17 63-4524—01 Object s T able T able 5. Objec t s. Object Name Type and Instance Object Property TB7200C5x14B TB7200F5x14B TB730.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 18 Filter Alarm BI 36 Present_Va lue (R) Service Alarm BI 37 Present_Value (R) .
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 19 63-4524—01 Proportional Band MV 65 Present_Value (R,W) Auto Fan BV 66 Present_Value (R,.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 20 S t andard Object T ypes Supported T a ble 6. St andard object types supported.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 21 63-4524—01 Property V alue Ra nge Restrictions T able 8. Property value range restrictions. Object name Object Type and inst ance Minimum range value Maximum range value Default value Room Temperature AV 7 -39.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 22 Property Enumeration Set s for BV & BI Object s T able 9. Prop erty enumeration sets for BV and BI object s. (**) This object will be linked to the value of the “UI 3 Conf iguration” obje ct.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 23 63-4524—01 Enumeration Set s for MV Objects T able 10. Proper ty enumera tion sets fo r MV objects . NOTES: 1. Enumeration sets for MV16 depends on Sequence of Operation (MV15) value upon device discovery .
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 24 T able 10. Property e numeratio n sets for MV objects. (Continued) 6. Enumeration sets for MV26 depends on Control T ype (BV75) value and Pipe Numbe r (MV52) value upon device dis- covery .
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 25 63-4524—01 BV75 Value MV52 Ind ex MV27 Object Name Function MV26 State Text Index Defau lt Value On/Off 1 (2 pipe) Heat/Cool .
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—0 1 26 Fan Mode Sequence MV 58 1 Low-Med-High On-Auto 2 Low-High 3 Low-Med-High-Au to 4 Low-High-Auto 5O n - A u t o Temp.
BACNET INTEGRATION MANUAL F OR TB7200 & TB7300 SERIES THERMOSTATS 27 63-4524—01 Floating Motor Timing MV 76 1 0.5 minute 1.5 minutes 2 1 minute 3 1.5 minutes 4 2 minutes 5 2.5 minutes 6 3 minutes 7 3.5 minutes 8 4 minutes 9 4.5 minutes 10 5 minutes 11 5.
BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS Automation and Control Solutions Honeywell International Inc. 1985 Douglas D rive North Golden Valley, MN 55422 Honeywell Limi ted-Honeywell Limi tée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.
Een belangrijk punt na aankoop van elk apparaat Honeywell TB7200 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honeywell TB7200 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honeywell TB7200 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honeywell TB7200 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honeywell TB7200 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honeywell TB7200 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honeywell TB7200 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honeywell TB7200 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.