Gebruiksaanwijzing /service van het product KMD-901MWH van de fabrikant Hoshizaki
Ga naar pagina of 27
Hoshizaki “A Superior Degree of Reliability” www .hoshizaki.com Models KMD-901MAH KMD-901MWH KMD-901MRH Modular Crescent Cuber Hoshizaki America, Inc.
IMPORTANT Only qualied service technicians should attempt to install, service, or maintain this icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual.
3 IMPORTANT This manual should be read carefully before the icemaker is installed and operated. Only qualied service technicians should install, service, and maintain the icemaker. Read the warnings contained in this booklet carefully as they give important information regarding safety.
4 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 946Z COMPONENT See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel.
5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 946Z COMPONENT 2. KMD-901MWH (water-cooled) See the nameplate for electrical and refrigeration specications.
6 3. KMD-901MRH (remote air-cooled) See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel. Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment.
7 B. Dimensions / Connections 1. KMD-901MAH Unit: mm [inches].
8 2. KMD-901MWH Unit: mm [inches].
9 3. KMD-901MRH Unit: mm [inches].
10 II. Installation and Operating Instructions A. Checks Before Installation IMPORTANT 1. Install in accordance with all applicable national, state, and local regulations. . Remove the shipping carton, tape, and packing material. If any are left in the icemaker, it will not work properly.
11 C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +38°C); Normal operating water temperature should be within +45°F to +90°F (+7°C to +3°C).
1 E. Electrical Connection WARNING 1. Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the junction box. . Electrical connections must meet national, state, and local electrical code requirements.
13 F. Installation of Remote Condenser Unit 1. Checks Before Installation 1) Remove the shipping carton, tape, and packing material. ) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blade moves freely.
14 3. Setup 1) Secure the legs to the remote condenser unit with eight M8×16 mm hexagon bolts and M8 nuts as shown in the illustration. See Fig. 5. ) The legs have eight mounting holes. Secure the legs with eight bolts (not included). Fig. 5 Hexagon Bolt with Split Lock Washer and Flat Washer M8 Hexagon Nut 4.
15 Factory Line Set Installation 1) Route the factory line set (1/" OD discharge line and 3/8" OD liquid line) from the remote condenser unit to the icemaker. See Fig. 6. Factory fabricated line sets are precharged and do not need to be evacuated.
16 5. Electrical Connection WARNING 1. Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these code requirements could cause severe injury to individuals or extensive damage to equipment. . Be sure to install a proper ground from the icemaker to the remote condenser unit.
17 G. Water Supply and Drain Connections See Fig. 9 CAUTION To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.
18 Fig. 9 KMD-901MAH KMD-901MRH KMD-901MWH with Storage Bin Icemaker Drain Outlet 3/4" FPT Icemaker W ater Supply Inlet 1/2" FPT Condenser W ater Supply Inlet 1/2" FPT Condenser Drain Outlet 3/8" FPT Separate piping to approv ed drain.
19 H. Final Checklist 1) Is the icemaker level? ) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (+7°C to +38°C) and the water temperature within +45°F to +9.
0 I. Startup CAUTION 1. All parts are factory-adjusted. Improper adjustments may result in failure. . If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor. 3. Do not operate the unit in the "WASH" position without water in the water tank.
1 III. Cleaning and Maintenance IMPORTANT Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the equipment. A. Cleaning and Sanitizing Instructions HOSHIZAKI recommends cleaning this icemaker at least once a year.
1. Cleaning Procedure 1) Dilute 13.5 . oz. (400 ml) of recommended cleaner Hoshizaki "Scale Away" or "LIME- A-WAY," (Economics Laboratory, Inc.) with .5 gal. (9.5 l) of warm water. ) Remove all ice from the evaporator and the storage bin.
3 9) Fully open the cleaning valve on the left side wall of the machine compartment. 10) Move the control switch on the control box to the "WASH" position. Replace the insulation panel and the front panel in their correct positions. 11) Turn on the power supply to start the washing process.
4 3) Pour the sanitizing solution into the water tank. 4) Replace the insulation panel and the front panel in their correct positions. Note: Make sure that the control switch is in the "WASH" position and the cleaning valve is open. 5) Turn on the power supply to start the sanitizing process.
5 3. Air Filters (air-cooled model only) Plastic mesh air lters remove dirt and dust from the air, and keep the condenser from getting clogged. As the lters get clogged, the icemaker’s performance will be reduced. Check the lters at least twice a month.
6 6) Blow the icemaker water supply line out using the compressed air or carbon dioxide supply. 7) Close the icemaker water supply line drain valve. 3. Drain the water tank: 1) Turn off the power supply. ) Move the control switch to the "OFF" position.
7 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A1WD10B.
Een belangrijk punt na aankoop van elk apparaat Hoshizaki KMD-901MWH (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hoshizaki KMD-901MWH heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hoshizaki KMD-901MWH vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hoshizaki KMD-901MWH leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hoshizaki KMD-901MWH krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hoshizaki KMD-901MWH bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hoshizaki KMD-901MWH kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hoshizaki KMD-901MWH . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.