Gebruiksaanwijzing /service van het product KML-700MWH-M van de fabrikant Hoshizaki
Ga naar pagina of 20
Hoshizaki “A Superior Degree of Reliability” www .hoshizaki.com Model KML-700MWH-M Low-Profile Modular Crescent Cuber Hoshizaki America, Inc. Issued: 10-13-2009 I N S T R U C T I O N M A N U A L .
IMPORTANT Only qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual.
3 CONTENTS Important Safety Information ................................................................................................. 4 I. Specications ............................................................................................
4 Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury.
5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT I. Specications A. Nameplate Rating 1. KML-700MWH-M (water-cooled marine) See the nameplate for electrical and refrigeration specications.
6 B. Dimensions/Connections 1. KML-700MWH-M (water-cooled marine) Unit: in. (mm).
7 II. Installation and Operating Instructions WARNING 1. This icemaker must be installed in accordance with applicable international, national, state, and local regulations. . CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation.
8 C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C).
9 E. Electrical Connection WARNING 1. Electrical connection must be hard-wired and must meet international, national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, re, or severe damage to equipment.
10 F. Water Supply and Drain Connections See Fig. 4 or 5 WARNING 1. Water supply and drain connections must be installed in accordance with applicable international, national, state, and local regulations. . Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C).
11 Fig. 4 KML-700MWH-M Connection to an Open Drain System 2. Water-Cooled Condenser a) Connection to an Open Drain System • Condenser water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
1 Condenser Return Line Shut-Off Valve Condenser Return Line Drain Valve Icemaker Drain Outlet 3/4" FPT Icemaker Water Supply Inlet 1/" FPT Fig. 5 Condenser Water Supply Inlet 1/" FPT Condenser Return Outlet 3/8" FPT Separate piping to approved drain.
13 G. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/storage bin.
14 H. Startup WARNING 1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. . If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor.
15 III. Cleaning and Maintenance WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the unit. Make sure that none have fallen into the dispenser unit/storage bin.
16 8) In bad or severe water conditions, clean the oat switch assembly as described below. Otherwise, continue to step 9. a. Remove the 3 screws securing the oat switch assembly, then remove the assembly. b. Remove the retainer rod from the bottom of the oat switch housing, then remove the oat.
17 2. Sanitizing Procedure - Following Cleaning Procedure 1) Dilute 1.5 . oz. (37 ml or .5 tbs) of a 5.5% sodium hypochlorite solution (chlorine bleach) with .5 gal. (9.5 l) of warm water. ) Remove the front insulation panel. 3) Pour the sanitizing solution into the water tank.
18 C. Preparing the Icemaker for Long Storage CAUTION 1. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage.
19 3) Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve. 4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.
0 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A1HL10A.
Een belangrijk punt na aankoop van elk apparaat Hoshizaki KML-700MWH-M (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hoshizaki KML-700MWH-M heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hoshizaki KML-700MWH-M vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hoshizaki KML-700MWH-M leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hoshizaki KML-700MWH-M krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hoshizaki KML-700MWH-M bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hoshizaki KML-700MWH-M kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hoshizaki KML-700MWH-M . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.