Gebruiksaanwijzing /service van het product ProLiant DL80 G9 van de fabrikant HP
Ga naar pagina of 147
HP Pr oL ian t DL80 Gen9 Serv er Us er Gui de Abstract This document is for the person wh o installs, administers, and trouble shoots servers and storage systems . HP assumes you are quali fied in the servicing of comp uter equipment a nd trained in recogniz ing hazards in products wit h hazardous energy levels.
© Copyright 2014 Hewlett- Packard Development Company, L.P. The information contained herei n is subject to change witho ut notice. The only warranties for HP products and services a re set forth in the express warranty statements accompanyin g such products and services.
Contents 3 Con tents Component identification ............................................................................................................... 7 Front panel co mponents ...................................................................
Contents 4 Hardware options installation ....................................................................................................... 43 Introduction ..........................................................................................
Contents 5 HP Redundant Power S upply cabling (hot - plug) ............................................................................... 10 5 Front panel cabling .......................................................................................
Contents 6 Preventing electrostatic discharge ............................................................................................................ 127 Grounding methods to prevent electrostatic discharge .......................................
Component ident ification 7 C om ponen t i dentif i cati on F ront panel comp onents • 4- bay LFF non - hot - plug drive model Item Description 1 USB 2.
Component ident ification 8 • 8- bay LFF hot - plug drive model Item Description 1 USB 2.0 conne ctor 2 Serial label pull tab (" Serial label pull tab information " on page 8 ) 3 Box 2 LFF hot - plu g drives 4 Box 3 LFF hot - plu g drives • 12 - bay LFF hot - plug dr ive model Item Description 1 Box 1 LFF hot - plu g drives 2 USB 2.
Component ident ification 9 F ront panel LEDs and b uttons • Front panel LEDs and buttons in a 4 - bay L FF chassis with thumbs crew rack ears • Front panel LEDs and bu ttons in an 8 - bay LFF cha.
Component ident ification 10 Item Description Status 1 UID button/LED* Solid blue = Activated Flashing blue: • 1 Hz/cycle p er sec = Remote management or firmware upgr ade in progress • 4 Hz/cycle.
Component ident ification 11 R ear panel comp onents Item Description 1 Slot 7 PCIe 3 x16 (16, 8, 4, 1) low - p rofile, sta ndup 2 Slot 6 PCIe 3 x8 (8, 4, 1) low - profile, standup 3 Slot 4 PCIe 3 x8 .
Component ident ification 12 R ear panel LEDs Item Description Status 1 UID LED Solid blue = Activated Flashing blue: • 1 Hz/cycle per sec = Remote management or firmware upg rade in progre ss • 4.
Component ident ification 13 P CIe riser board slot def initions • GPU riser cage a ssembly: Install in the primary PCIe riser board conne ctor (" GPU enablement option " on page 80 ).
Compone nt ident ification 14 • FlexibleLOM riser cage assembly: Install in the secondary PCIe riser board connector (" Fle xibleL OM enablement option " o n page 85 ).
Component ident ification 15 S ystem board c omponents Item Description 1 PCIe3 x16 ( 16, 8, 4, 1) s lot 1 for low - profile, stan dup expansion boa rd or riser cage options ( GPU riser cage or two- s.
Component ident ification 16 Item Description 20 Processor 1 D IMM slots 21 Fan connector 3 22 Fan connector 2 23 Fan connector 1 24 Processor 1 25 HP Smart Storage Battery connector 26 6- pin drive power conne ctor 27 Internal USB 3.
Component ident ification 17 Position Default Function S4 Off Reserved S5 Off Off = Power - on password is enabled. On = Power - on password is disabled. S6 Off Off = No function On = ROM rea ds system confi guration as invalid. S7 Off Off = Set default boot mode to UEFI.
Component ident ification 18 • 4- bay LFF non - hot - plug drive numbering • 8- bay LFF non - hot - plug dri ve numbering • 8- bay LFF hot - plug drive numbering • 12 - bay LFF hot - plug dr i.
Component ident ification 19 Item LED Status Definition 1 Locate Solid blue The drive is being identif ied by a host applicat ion. Flashing blue The drive carrier firmware is being upd ated or requ ires an update. 2 Activity ring Rotating green Drive acti vity Off No drive activit y 3 Do not remove Solid white Do not remove t he drive.
Operations 20 Oper atio ns P ower up the server To power up the server, press the Power On/Standby button. P ower down the server Before powering down the server for any upgrade or mainten ance procedures, perfor m a backup of crit ical server data and prog rams.
Operations 21 o In a server th at uses thumbscr ew rack ears, l oosen the captiv e thumbscrews t hat secure the server faceplate to the front of the en closure, and t hen slide the serv er out of the enclos ure. o In a server th at uses quick - relea se latch rack ear s: i.
Operations 22 2. After performing the installation or maintenance procedure, slide the ser ver back into the enclosure, and then press the server firmly into the enc losure to secure it in place. 3. Do one of the following: o In a server that uses thumbscrew rack ears, tighten the captive thumbscrews.
Operations 23 A ccess the product rear pane l O pening the cable management arm To access the server rear panel: 1. Release the cable management arm. 2. Open the cable manag ement arm. The cable manageme nt arm can be right - mounted o r left - mounted.
Operations 24 R emove the security bezel (option al) To access the fron t panel components, unlock and then remov e the security bezel. The security bezel is on ly supported in serve rs that are using the quick - release latch rack ears.
Operations 25 6. Lift and remov e the access p anel. Turn the access panel ov er to locate the HP ProLiant D L80 Gen9 Server hood lab el. This label provides convenient access to component identification, LED s tatus indicators, and system maintenance switch settings information.
Operations 26 2. Align the hole in the access panel latch w ith the guide pin on the chassis. 3. Close the acces s panel latch. The access panel slid es to a closed posit ion.
Operations 27 5. Remove the ai r baffle. I nstall the ai r baffle CAUTION: For proper cooling, do not op erate the server without the a ccess panel, baffles, expansion slot cove rs, or blanks insta lled. If the serv er supports hot - p lug components, minimiz e the amount of time the access panel is o pen.
Operations 28 4. Power up the serv er (on page 20 ). R emove the PCI riser c ages CAUTION: To prevent damag e to the server or e xpansion boards, power down t he server, and disconnect all power cords before removi ng or installing the PCI riser cage.
Operations 29 a. Disconnect all cables connected to existing expansio n boards. b. Loosen the captive thumbscrew on the front end of the PCI riser cage, and then remove t he screw from its rear end. c. Grasp the PCI riser cage at t he touch points and lift it out of the chassis.
Operations 30 c. Tighten the captive thumbscrew on the front end of th e riser cage. 2. If you are installing the Flexib leLOM riser cage in the seco ndary PCIe riser locatio n, do the following: a. Align the riser board with the corresponding connectors on the system board, and then press down the PCI riser cage.
Operations 31 6. Power up the serv er (on page 20 )..
Setup 32 S etup O ptional installa tion services Delivered b y experienced, certified engin eers, HP Care Pack services help y ou keep your serve rs up and running with s upport packages tailor ed specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and so ftware support into a single pac kage.
Setup 33 • Leav e a minimum clearance of 63.5 cm (25 in) in fron t of the rack. • Leave a minimum clear ance of 76.2 cm (30 i n) behind the rack. • Leave a minimum c learance of 121.9 cm (48 in) from the back of the rac k to the back of another rack or row of racks.
Setup 34 P ower require ments Installation of this eq uipment must comply wit h local and regional electri cal regulations governing the installation of information technology equipment by licensed elec tricians.
Setup 35 WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment: • Observe local occu pational health and safe ty requirements and gu idelines for manual material handling.
Setup 36 WARNING: When insta lling a server in a telco rack, be sure that th e rack frame is a dequately secured at the top and bottom to the bui lding structure. I dentifying the c ontents of the server ship ping carton Unpack the server shipping carton and locate the materials and documentation necessary for installing the server.
Setup 37 WARNING: This server is ver y heavy. To reduce t he risk of persona l injury or da mage to the equipment: • Observe local occu pational health and safe ty requirements and gu idelines for manual material handling.
Setup 38 d. Position the power cord inside the clip, and then close the clip. e. Slide the clip forwa rd until it is flush agai nst the edge of the power cord plug.
Setup 39 b. Bend the plug end of the power cord in the p osition shown in the follo wing image. c. Secure the power cord in the hook - an d - loop strap as shown in the following image. 5. Employ best prac tices to route and manage th e power cords and other c ables in the server rear pan el.
Setup 40 WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The g rounding plug is an im portant safety feature. • Plug the power cord int o a grounded (earthed) electrical outlet that is easily accessible at all times.
Setup 41 I nstalling th e operating system This HP ProLiant server doe s not ship with provisioning media. Everything needed to manage and ins tall the system soft ware and firmwa re is preloade d on the server. To operate properly, the server mus t have a supported operating system.
Setup 42 R egistering the ser ver To experien ce quicker serv ice and more efficient supp ort, regist er the product a t the HP Product Registration website ( http://register.
Hardware options installation 43 H ar d w ar e opti o ns inst allati on Introduction If more than one opt ion is being installed, read the installation instr uctions for all the hard ware options and identify simila r steps to streamline the ins tallation process.
Hardware options installation 44 Dr ive installation guidel ines When addin g drives to the ser ver, observe t he following genera l guidelines: • The system automati cally sets all device n umbers. • Populate drive bays , based on the drive numbe ring sequence.
Hardware options installation 45 5. Remove the two metal brackets from the drive c arrier. 6. Install the drive in the carrier. 7. Install the drive. CAUTION: To preve nt improper cooling and thermal damage , do not operate the server unless all bays are popul ated with either a co mponent or a blank.
Hardware options installation 46 I nstalling a hot - plug drive CAUTION: To preve nt improper cooling and thermal damage , do not operate the server unless all bays are popul ated with either a co mponent or a blank.
Hardware options installation 47 To configur e arrays, see th e HP Smart Sto rage Administrator User Gu ide on the HP w eb s ite ( http://www.hp.com/go/smartstorage/docs ).
Hardware options installation 48 7. Connect the BP2 power connector of the preinstalled drive po wer cable to the new 4 - bay LFF non - hot - plug drive backpla ne. 8. If installed, remove the primary PCI riser cag e (" Remove the PCI r iser cages " on page 28 ).
Hardware options installation 49 14. Power up the serv er (on page 20 ). 15. Install the drives (" Drive opt ions " on page 43 ). D rive cab le options Use these drive cable options to install an HP Host B us Adapter or an HP Smart Array Controller board option.
Hardware options installation 50 b. Release the M ini - SAS cable from the wh ite cable clip o n the left hand side o f the chassis. 8. Install the HBA: a.
Hardware options installation 51 b. Install the HBA. 9. Connect the Mi ni - SAS cable: a. Connect one end of the Mini - SAS cable to port 1 of the HBA. b. Route the Mini - SAS c able through the white cable clip on the left hand si de of the chassis, and then connect the cable to t he drive backplan e.
Hardware options installation 52 M ini - SAS Y - cable option for 8 - bay LFF hot - plug drive configuration s This section describes how to connect the Mini - SAS Y - cable option to upgr ade the 8 -.
Hardware options installation 53 b. Release the M ini - SAS cables fro m the white cab le clip on the left ha nd side of the cha ssis. c. Remove the HBA.
Hardware options installation 54 9. Install the storage controller. 10. Connect the Mini - SAS Y - cable: a. Connect the common end of the Mi ni - SAS Y - cable to the controller option.
Hardware options installation 55 C ontroller options The server shi ps with an embedded HP D ynamic Smart Array B140i Controller. Fo r more information a bout the controller and its feature s, see the HP Dynamic Smart Array B140i RAID Controller User G uide on the HP website ( http://www.
Hardware options installation 56 Storage controller/ HBA option Slot Cable option Drive configuration HP H24x Smart H BA or any supported l ow - profile HBA Onboard PCIe 3 x8 slot 3 1 Mini - SAS cable.
Hardware options installation 57 b. Install the cache module on th e storage controller. 6. Install the storage controller (" Expansion bo ard options " on page 73 ). 7. If a cache module is installed on a storage controller locat ed in the onboard PCIe3 x8 slot 3, conn ect the cache module back up power cable to the system board.
Hardware options installation 58 c. Connect the cache mo dule backup power cable to the system board. 9. Connect all necessar y internal cables to the stora ge controller. For int ernal drive cabling information, see " Storage cabling (on page 97 ).
Hardware options installation 59 b. Disconnect each power cord from the ser ver. 3. Do one of the following: o Extend the server from the rack (o n page 20 ). o Remove the s erver from the r ack (on page 22 ). 4. Remove the acces s panel (on page 24 ).
Hardware options installation 60 IMPORTANT: Processor socket 1 must be populated at all times or the serv er does not fun ction. For more informa tion about product features, specifica tions, options, config urations, and compat ibility, see the product QuickSpecs on the HP website ( http://www.
Hardware options installation 61 7. Open each of the processo r locking levers in the ord er indicated in the following il lustration, and then open the processor retain ing bracket. 8. Remove the clear processor socket cover. Retain th e processor soc ket cover for fut ure use.
Hardware options installation 62 9. Install the processor. Verify that the processor is ful ly seated in the processor retaining bracket by visually inspecting t he processor in stallation guid es on either side o f the processor. THE PINS ON THE SYSTEM BOARD AR E VERY FRAGILE AND E ASILY DAMAGED.
Hardware options installation 63 11. Press and hold the pr ocessor retaining bracket in p lace, and then close each pro cessor locking lever. Press only in the area indicated on the processor re taining bracket. 12. Remov e the therma l interface prot ective cover from the heatsink.
Hardware options installation 64 c. Finish the installation by completely tightening the screws in the same s equence. 14. To determine which fan blanks need to be removed to install the additional fans, see " Fan population guidelines (on page 66 ).
Hardware options installation 65 17. Connect the fan cable to the system board. Store any unu sed fans as spares. 18. Insta ll the air baffle (on page 27 ). 19. Install the access panel (on page 25 ). 20. Do one of t he following: o Slide the server into the rack.
Hardware options installation 66 F an population guidelines To provide suffic ient airflow to the sy stem if a fan fails, the serv er supports red undant fans.
Hardware options installation 67 a. Disconnect each p ower cord from the power sour ce. b. Disconnect each po wer cord from th e server. 3. Do one of the following: o Extend the server from the rack (o n page 20 ). o Remove the s erver from the r ack (on page 22 ).
Hardware options installation 68 11. Install the access panel (on page 25 ). 12. Do one of t he following: o Slide the server into the rack. o Install the server into the rack (" Installi ng the server into the rack " o n page 36 ). 13. Pow er up the server (on page 20 ).
Hardware options installation 69 performance - tuned fo r HP ProLiant and Bl adeSystem serv ers and provides futur e enhanced support through HP Active Health and man ageability software. M emory subsystem arch itecture The memory s ubsystem in th is server is divid ed into channels.
Hardware options installation 70 D IMM identification To determine DIMM characteristics, use the label attac hed to the DIMM and the following illus tration and table.
Hardware options install ation 71 Advanced Memory Protection options are con figured in the BIOS/Pla tform Config uration (RBSU). If the requested AMP mode i s not supported by the in stalled DIMM configur ation, the server bo ots in Advanced ECC mode.
Hardware options installation 72 For more infor mation about serv er memory, see t he HP website ( http://www.hp.com/go/memory ). The DIMM speed s supported in this server are list ed in the following.
Hardware options installation 73 7. Install the DIMM. 8. Install the air baffle (on page 27 ). 9. Install the access panel (on page 25 ). 10. Do one of t he following: o Slide the server into the rack. o Install the server into the rack (" Installi ng the server into the rack " o n page 36 ).
Hardware options installation 74 4. Remove the acc ess panel (on page 24 ). 5. To install a low - profile, stan dup expansion board on the system board, do the following: a. Identify the expansion slot compatible with the new option, and then remove the cover opposite that slot.
Hardware options installation 75 b. Remove the ri ser slot cover. c. Verify that any switches or jumpers on the expansion board are set properly. For more information, see the documentation that ships with the option. d. Install the e xpansion board. Verify that the board is firmly seated in the slo t.
Hardware options installation 76 a. Remove the P CIe riser slot 4 cov er. b. Open the riser slo t retainer latch..
Hardware options installation 77 c. Install the expansion board. Verify that the board is firmly sea ted in the slot. 8. If the installed expansion boa rd requires intern al cabling to conn ectors cover ed by the air baff le, remove the air baffl e (on page 26 ).
Hardware options installation 78 o Remove the s erver from the r ack (on page 22 ). 4. Remove the acces s panel (on page 24 ). 5. Remove the ai r baffle (on page 26 ).
Hardware options installation 79 8. Install the two - slot PCI riser cage. 9. Remove the f an blank from fan bay 1..
H ardware options installation 80 10. Install the fan in fan bay 1. CAUTION: To preve nt improper cooling and thermal damage , do not operate the server unless all PCI slots have eith er an expansion slot cover or an exp ansion board installed. 11. Insta ll the air baffle (on page 27 ).
Hardware options installation 81 o Remove the s erver from the r ack (on page 22 ). 4. Remove the acces s panel (on page 24 ). 5. Remove the ai r baffle (on page 26 ). 6. Remove the pri mary PCI riser cage blank. 7. If necessary, release the hot - plug pow er supply GPU/BP1 power connector from the cable c lip.
Hardware options installation 82 8. Connect the common connector of the GPU/BP1 power extension cable to the hot - plu g power supply GPU/BP1 power conn ector.
Hardware options installation 83 10. Remove the ri ser slot cover. 11. Install the GPU in the GPU riser cage. 12. Insta ll the GPU riser cage..
Hardware options installation 84 13. Connect the GPU power cable to the GPU. 14. Remov e the fan blank from fan bay 1..
Hardware options installation 85 15. Install the fan in fan bay 1. 16. Insta ll the air baffle (on page 27 ). 17. Install the access panel (on page 25 ). 18. Do one of t he following: o Slide the server into the rack. o Install the server into the rack (" Installi ng the server into the rack " o n page 36 ).
Hardware options installation 86 6. Remove the c overs of the onbo ard PCIe3 x16 slot 4 a nd the FlexibleLO M riser slot. 7. Install the FlexibleL OM riser cage.
Hardware options installation 87 8. Install the Flexib leLOM adapter. 9. Remove the f an blank from fan bay 5..
Hardware options installation 88 10. Install the fan in fan bay 5. CAUTION: To preve nt improper cooling and thermal damage , do not operate the server unless all PCI slots have eith er an expansion slot cover or an exp ansion board installed. 11. Insta ll the air baffle (on page 27 ).
Hardware options installation 89 WARNING: To reduce the risk o f personal inj ury from hot surfa ces, allow the d rives and the internal system components to cool before touchi ng them. CAUTION: To preve nt damage to electric al components, properl y ground the server bef ore beginning any instal lation proce dure.
Hardware options installation 90 11. Release the n on - hot - plug power su pply cables from the cabl e clip. 12. Remov e the non - ho t- plug power suppl y.
Hardware options installation 91 a. Install the RPS backplane in the server. b. Connec t the RPS backplane cable s to the system bo ard. c. Secure the RPS back plane cables in the cable clips.
Hardware options installation 92 14. Install a hot - plug pow er input module in the power supp ly bay 1. 15. If you int end to enable power redunda ncy in the server, insta ll a second power input module in the power supply bay 2: a. Remo ve the powe r supply blank.
Hardware options installation 93 b. Bend the plug end of the power cor d in the position shown in th e following image. c. Secure the power cord in the hook - an d - loop strap as shown in the following image. 22. Conne ct the power cords to th e AC power source.
Hardware options installation 94 2. Retaining th e recovery key/ password (on page 95 ). 3. Enabling the Trusted Platform Module (o n page 96 ). Enabling the TPM requ ires accessing BIOS/P latform Configuration (RBSU) in HP UEFI System Utilities (on page 113 ).
Hardware options installation 95 5. Install the TPM board. Press down on the connector to seat the board (" System board components " on page 15 ). 6. Install the TPM security ri vet by pressing the rivet firmly into the system board. 7. Install the access panel (on page 25 ).
Hardware options installation 96 key/passwo rd is required to en ter Recovery Mod e after BitLoc ker detects a possib le compromis e of system integrity. To help ensure ma ximum security, observ e the following guidelines when retaining the recov ery key/password: • Always store the re covery key/password in multiple locations.
Cabling 97 C abling Cabling overview This section provides guidelines that help you make informed decisions about c abling the server and hardware options to optimize performance . For informatio n on cabling peripheral comp onents, refer to the white pa per on high - density deployment at the HP website ( http://www.
Cabling 98 4- bay LFF hot - plug SATA drive cabling Item Description 1 Drive power cab le 2 Mini - SAS cable 4- bay LFF hot - plug SAS/SATA drive cabling • Drives connected to an HBA option Item Des.
Cabling 99 • Drives connected to an HP Smart Array Controller op tion Item Description 1 Drive power cab le 2 Mini - SAS cable 8- bay LFF non - ho t - plug SATA drive cabling Item Description 1 Driv.
Cabling 100 8- bay LFF hot - p lug SATA drive cabling Item Description 1 Drive power cab le 2 Mini - SAS cable 1 3 Mini - SAS cable 2 8- bay LFF hot - plug SAS/SATA drive cabling • Drives connected .
Cabling 101 • Drives connected to an HP Smart Array Controller op tion Item Description 1 Drive power cab le 2 Mini - SAS Y - cable 12- bay LFF hot - plug S AS/SATA drive cabling Item Description 1 .
Cabling 102 F BWC mo dule backup powe r cabling The FBWC so lution is a separ ately purchased op tion. This server only supports FB WC module installation (" Installing the storage contr oller and FBWC module options " on page 56 ) when an HP Smart Array P - Series controller is insta lled.
Cabling 103 HP Smart Storage Battery cabling F an cabling Item Description 1 Fan 1 cable 2 Fan 2 cable 3 Fan 3 cable 4 Fan 4 cable 5 Fan 5 cable 6 Fan 6 cable.
Cabling 104 G PU power cabli ng Item Description 1 GPU power cable (GPU connector of the GPU/BP1 power extension cable) 2 Hot - plug power supply GPU/BP1 power cable P ower suppl y cabling H P 550 - W.
Cabling 105 Item Description 2 16 - pin RPS c able H P Redundant Power Supply cabling (hot -plug) Item Description 1 GPU/BP1 power cable, requires the GPU/BP1 power extension cable 2 24 - pin power su.
Cabling 106 Item Description 1 USB 2.0 connector cable 2 Ambient temperature sensor cable 3 Front I/O cable • Front panel cablin g in a chassis with quick - release latch rack ears Item Description 1 Front I/O cable 2 USB 2.
Software and conf iguration util ities 107 S o f t w ar e and conf igur ati on u tilitie s Server mode The software and config uration utilities pres ented in this section operat e in online mode, offline mode, or in both modes.
Software and conf iguration util ities 108 Using iLO 4, you can do th e following: • Access a high - per formanc e and secure Integrat ed Remote Consol e to the server from anywhere in the world if you have a net work connection to the serv er. • Use the shared .
Software and conf iguration util ities 109 HP Active Health System does not collect info rmation about Active Health System users' operations, finances, customers, employees, par tners, or data cent er, such as IP ad dresses, host na mes, user names, a nd passwords.
Software and config ura tion utilities 110 H P Insight Remote Suppor t HP strongly recommends that you register your device for remote support to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or HP contractu al support agreement.
Software and conf iguration util ities 111 • Intelligent Prov isioning assists w ith the OS installation process by preparing the system for installing "off - the - shelf" and HP branded ve rsions of operating s ystem software and integrating opti mized HP ProLiant server support software.
Software and conf iguration util ities 112 • You want to install a new operating system on a server with an exi sting operating system. • You encounter an error when completing the steps of a factory - installed operating system installation.
Software and conf iguration util ities 113 H P UEFI System Utiliti es The HP UEFI S ystem Utilitie s is embedded i n the system ROM. The U EFI System Util ities enable you to perform a wide range of c.
Software and conf iguration util ities 114 The new boot option is appended to the boot orde r list. When you select a file, you are prompted to enter the boot option description (which is then displayed in the Bo ot menu), as well as any optional data to be passed to an .
Software and conf iguration util ities 115 E mbedded UEFI shell The system B IOS in all HP ProLian t Gen9 server s includes an Emb edded UEFI Shell in the ROM. The UEF I Shell environ ment provides an API, a comm and line prompt, and a set of CLI s that allow scripting, fil e manipul ation, and system information.
Software and conf iguration util ities 116 U tilities an d features H P Smart Storage Administrator HP SSA is a configuration and management tool f or HP Smart Array controllers. Starting with HP ProLiant Gen8 servers, HP SSA repl aces ACU with an enhanc ed GUI and additio nal configuratio n features.
So ftware and configuration utilities 117 • Auto (default) — If configured in Auto Mod e, USB 3.0 capable dev ices operate at USB 2.0 speed s in the pre - boot environment and du ring boot. When a USB 3.0 capable OS USB driver loads, USB 3.0 devices transit ion to USB 3.
Software and conf iguration util ities 118 U pdating firmware or System ROM Multiple meth ods exist to up date the firmwa re or System ROM: • HP Service Pack for ProLiant (on page 112 ) • FWUPDATE.
Software and conf iguration util ities 119 6. Change to the file system that contains the System ROM Flash Binary component for your server. Enter one of the fsx fil e systems avail able, such as fs0 or fs1 , and press Enter . 7. Use the cd command to change from the current directory to the directory that c ontains the binary file.
Software and conf iguration util ities 120 If you do not use Intelligent P rovisioning to install an OS, driv ers for some of the new hardwa re are required. These drivers, as well as other option dr ivers, ROM images, and value - add software can be do wnloaded as part of an SPP.
Software and conf iguration util ities 121 H P operating systems and virtualization software support for ProLiant server s For informa tion about specif ic versions of a supported opera ting system, see the HP website ( http://www.hp.com/go/ossupport ).
Troubleshootin g 122 T r ou ble shooting T roubleshooting resour ces The H P ProLiant Gen9 Tr oubleshooting Guide, V olume I: Trouble shooting pr ovides procedur es for resolving common problems an d .
System battery replacement 123 S y stem batter y r epla cement If the server no longer automatically displays the correct date and time, then replace the battery that provide s power to the real - time clock. Under norm al use, battery life is 5 to 10 years.
System battery r eplacement 124 To install the component: 1. Insert the battery with the "+" side facing up underneath the outer lip of the socket, and then press the battery down to secure it in place. 2. Install the access panel (on page 25 ).
Regulatory info rmation 125 R egulator y inf or mati on S afety and re gulatory compl iance For safety, environmental, and regulato ry information, see Safety and Compliance Inf ormation for Server , Storage, Power, N etworking, and Rack Prod ucts , available at t he HP website ( http://www.
Regulatory info rmation 126 Valid date format s include the following: • YWW , where Y indicates the year counting from within each new decade, with 2000 as the s tarting point. For exam ple, 238: 2 for 2002 and 38 for the w eek of September 9. In addition, 2010 is indicated by 0, 2011 by 1, 2012 by 2, 2013 by 3, and so forth.
Electrostatic dis charge 127 E lectr o stati c dis c har ge P reventing elec trostatic d ischarge To prevent d amaging the system, be awar e of the preca utions you need to follow when setting up the system or handling parts.
Specifications 128 S pec if i cati ons E nvironmental spec ifications Specification Value Temperature rang e* — Operating 10 ° C to 35 ° C (50 ° F to 95 ° F) Nonoperating - 30 ° C to 60 ° C ( - 22 ° F to 140 ° F) Relative humidity (noncondensing) — Operating Minimum to be t he higher (more moisture) of - 12°C (10.
Specifications 129 P ower supply specific ations Depending on the installed options and/or the regional loc ation where the server was purchased, the server is configured with one o f the following po.
Support and other resources 130 S uppo r t and other r es our ces B efore you contact HP Be sure to have the follo wing information available before you call HP : • Active Health S ystem log (HP ProLiant Ge n8 or later products) Download and have av ailable an Active Health System log f or 7 days befo re the failure was detected.
Support and other resources 131 providers or service partner s) identifies t hat the rep air can be accompl ished by the use of a CSR part, HP wil l ship that part directly to you for re placement. There are two categories of CSR parts: • Mandatory — Parts for which customer self repair i s mandatory.
Support and other resources 132 Pour plus d'inform ations sur le programm e CSR de HP, contactez vot re Mainteneur Agrée local. Pour plus d'informat ions sur ce progr amme en Amériq ue du Nord, consu ltez le site Web HP ( http://www.h p.com/go/selfrepair ).
Support and other resources 133 HINWEIS : Einige Teile sind n icht für Customer S elf Repair ausg elegt. Um d en Garantieanspr uch des Kunden zu erf üllen, muss da s Teil von einem HP Servicepartne r ersetzt werden. Im illustriert en Te ilekatalog sind diese Tei le mit „No“ bzw.
Support and other resources 134 sustitucion es que lleve a ca bo el cliente, H P se hará cargo de todos l os gastos de env ío y devolución d e componentes y esco gerá la empresa de transpo rte que se utilice para di cho servicio.
Support and other resources 135 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas pe ças também são proje tadas para o reparo feito pelo clien te. No entanto, se desejar que a HP as subs titua, pode haver ou não a cobranç a de taxa adicional, depe ndendo do tipo de s erviço de garantia des tinado ao produto.
Support and other resources 136.
Support and other resources 137.
Acronyms and ab breviations 138 A c r on y ms and a bbr e v i ati ons ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protec tion API application program i nterface ASHRAE Ameri.
Acronyms and ab breviations 139 DPC DIMMs per cha nnel FAT file allocation ta ble FBWC flash - backed write cache GPU graphics processin g unit HBA host bus adapter HP SIM HP Systems Insight Manager H.
Acronyms and ab breviations 140 LOM Lights - Out Management LRDIMM load reduced dual in - line memory module LV low voltage (DIM M voltage) NMI nonmaskable inte rrupt NVRAM nonvolatile memory OA Onboa.
Acronyms and ab breviations 141 RoHS Restriction of Haz ardous Substances RPS redundant power supply SAS serial attached SCSI SATA serial ATA SD Secure Digital SIM Systems In sight Manager SPP HP Serv.
Acronyms and abbrevi ations 142 USB universal serial bus VC Virtual Connect VCA Version Contr ol Agent VCRM Version Contr ol Repository Manager xHCI Extensible Host Controller Interface.
Documentation feedback 143 D oc ument ati on f eedbac k HP is committed to pro viding documentation that mee ts your needs. To help us improve th e documentation, send any erro rs, suggestion s, or comments to Documentation Feedback ( mailto:docsf eedback@hp.
Index 144 A access panel, inst all 25 access panel, remo ve 24 Active Health System 107, 108 ACU (Array Config uration Utility) 116 Advanced ECC memor y 71, 72 Advanced ECC populat ion guidelines 72 A.
Index 145 environmental requirements 32 environmental specifications 128 Erase Utility 107, 111 error messages 122 EuroAsian Econom ic Commission 125 expansion board optio ns 73 extending ser ver from.
Index 146 LEDs, power fault 10 LEDs, power supply 10 LEDs, rear panel 12 LEDs, unit identification (UID) 9, 12 legacy USB suppor t 116 M maintenance guid elines 117 mechanical specificat ions 128 memo.
Index 147 requiremen ts, power 34 requiremen ts, site 33 requiremen ts, space 32 requiremen ts, temperatur e 33 RoHS 126 ROM legacy USB su pport 116 ROM redundancy 11 7 ROM - Based Setu p Utility (RBS.
Een belangrijk punt na aankoop van elk apparaat HP ProLiant DL80 G9 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen HP ProLiant DL80 G9 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens HP ProLiant DL80 G9 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding HP ProLiant DL80 G9 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over HP ProLiant DL80 G9 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van HP ProLiant DL80 G9 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de HP ProLiant DL80 G9 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met HP ProLiant DL80 G9 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.