Gebruiksaanwijzing /service van het product Series 2017 van de fabrikant Hubbell
Ga naar pagina of 20
Hubbell Industrial Controls, Inc. Specification 2000 • August 2000† • Replaces Sept. 1997 Eu c l i d ™ Pendan ts & Pushbuttons † Replaces all previous catalogs and specification lists. HUBBELL 2000 Table of Contents Series 2001 Pushbutton Stations, Euclid Type HD & WP .
2001 Specifications Pushbutton Stations Euclid T ype HD, S, WP & WSM – Pendant & Surface Mounting – Heavy Duty – NEMA 1 or 3R – Single & T wo Speed Featur es Euclid ’ s oldest line of rugged time proven pushbutton stations incorporate basic modular construction and are designed for heavy duty applications of all kinds.
Diagrams & Dimensions 2001 3.625" 2.625" "B" "A" "P" Pipe Size 5" 0.375" 8.625" 1.25" Pipe Tap "A" 3.625" 2.625" 1.062" 2.25" 2.25" 0.5" 1.812" 1.
2015 / 16 / 17 Specifications Euclid ™ T ype PBC / WPBC / XPBC Pendant Pushbutton Stations Application PBC cam-operated pushbuttons are engineered for all heavy- duty applications that require ut- most reliability and the combi- nation of single and multi-speed perfor mance such as crane and mill drives.
2015 Application Info 2015 / 16 / 17 Series PBC Pendant Push- button Stations represent the ultimate in custom engi- neering for specialized ap- plications that can benefit from the unique operating cam feature. • 150V AC or 300VDC • NEMA 1 – General Pur- pose, Indoor Ser vice • Steel enclosure body .
2015 / 16 / 17 2016 Application Info WPBC stations use the same pushbutton inserts as the PBC Stations. The WPBC enclosures are made of machined extruded aluminum. • 150V AC or 300VDC • NEMA 3R – Rainproof & Sleet Resistant, Outdoor Ser vice (Standard) • Up to five speed points and eight common circuits for each direction.
2017 Application Info 2015 / 16 / 17 XPBC Stations use inserts similar to the PBC and WPBC stations. XPBC enclosures are made of cast aluminum and are engineered to meet hazard- ous duty requirements. • 150V AC or 300VDC. • Rated for NEMA T ype 7, Class 1, Group C or D, Div .
3.12" 3.38" 0.5" "A" "B" Pipe Size 0.38" Suspension Cable Hole (2) 4.00" 4.00" 0.88" 0.75" "A" "B" Pipe Size 0.38" Suspension Cable Hole (2) Figure 3 T ype WPBC, NEMA 3/4/13 Enclosure 2015 / 16 / 17 Dimensions No.
Dimensions 2015 / 16 / 17 Figure 4 T ype SWPBC, NEMA 3/4/13 Enclosure Surface Mounting 6.00" 5.88" 2.00" 0.5" "A" "B" Pipe Size 0.63" Mtg. Hole (2) 6.00" 6.12" 2.00" "B" Pipe Size 5.
2020 Specifications Over a half centur y of Euclid experience in pushbutton de- sign and manufacturing has been incorporated into the unique PBP design. These highly reliable pendants fea- ture maximum safety and du- rability , ease of installation and maintenance and mini- mum down time.
Specifications 2020 Hard Rubber Guard Button Cover Plug-In Insert T erminal Base Back Cover Universal Hanger Bracket Pilot Light Pilot Light Nameplate Pilot Lens Enclosure Number of Approx. Buttons ” A ” Wt. (lbs.) 2 7.87" 2.5 5 † 13.69" 4.
2030 Specifications Hubbell ’ s Compact Pendant Stations are typically used to control industrial cranes and hoists or the remote control of industrial machines.
Diagrams & Dimensions 2030 13 440/428-1161 • Fax 440/428-7635 HUBBELL Compact Assembly Parts List Part No. Qty. Assembly Parts Listing 1 1 Front Housing 2 1 1 ⁄ 2 " NPT Locknut Gnd. Brkt. 3 3 Terminal Clamps 4 1 Pin * 5 1 Crimp Sleeve * 6 1 Gasket 7 1 Rear Housing 8 3 #8-32 Hex Nut 9 2 #8-32 x 1 3 ⁄ 4 " Lg.
2040 Specifications Euclid ™ PBM Pendant Pushbutton Stations 440/428-1161 • Fax 440/428-7635 The Multi-Purpose PBM Pen- dant Pushbutton Stations have been designed to use 22mm NEMA 4X pushbutton ele- ments to provide full flexibility .
Specifications 2040 440/428-1161 • Fax 440/428-7635 HUBBELL Standar d Pushbuttons Hubbell ’ s standard 22 mm pushbuttons feature polyester construction for superior corrosion resistance, and the #6 terminal screws have self-lifting captive wire clamps to accommodate #22 through 2 – #12 wires per terminal.
56 34 12 21 43 65 54321 54321 3 2 14 5 3 2 14 5 Up/Fwd Down/Rev Top Rear View Jumper by Customer Symbol Key M – Maintained Position; S – Spring Return Position X – Contact Closed; O – Contact .
Specifications 2040 ELK1 Label Pack ELK2 Label Pack Standard Pushbuttons 0.63" (16) 0.86" (22) 0.86" (22) 0.91" (23) 1.22" (31) 1.42" (36) Selector Switches 0.71" (18) 0.91" (23) 0.98" (25) 1.22" (31) 1.
4211 Specifications The Euclid Mini-Master Switch uses a handle oper- ated cam switch mechanism in a NEMA rated housing. It is engineered for use where master switch control is preferred, for CMAA duty overhead crane and similar applications. • Housings for surface or flush mounting.
Diagrams & Dimensions 4211 44 ° 44 ° Max. Travel Max. Travel Off 5" Rad. 2.25" 2.50" 5.75" 0.44" 0.31" 6.75" 6.12" 5.25" 0.31" 0.75" 4.38" 3.50" 0.44" 2.88" 0.75" 0.
Prices Are Subject T o Change Without Notice Hubbell Industrial Contr ols, Inc. a subsidiary of Hubbell Incorporated 50 Edwards Street, Madison, Ohio 44057 (440) 428-1161 • Fax (440) 428-7635 JPS-800-2M © 2000 Printed in U.
Een belangrijk punt na aankoop van elk apparaat Hubbell Series 2017 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hubbell Series 2017 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hubbell Series 2017 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hubbell Series 2017 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hubbell Series 2017 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hubbell Series 2017 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hubbell Series 2017 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hubbell Series 2017 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.