T ype A Models T ype A Models T ype A Models Form# 42856-01 20090130 ©2009 Hunter Fan Co. For Y our Records and W arranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. __________________________________________ Model Name __________________________________________ Model No.
2 42856-01 • 01/30/09 • Hunte r Fan Company T ab le Of Contents 1 • Getting Ready ...................... 4 2 • Installing the Hanger Brack et ....... 5 3 • Ass embling and Hanging the Fan ... 6 4 • Wiring the Fan ..................... 7 5 • Ins talling the Motor Housing .
3 42856-01 • 01/30/09 • Hunte r Fan Company M ountin g and O ptional Ac ce ssorie s Understan ding Mountin g Hunte r ’ s patent ed mounting syste m provides you maximum eas e in installing your fan. is fan was de signed to be mounted only on at ceilings and can b e use d on ceilings less than 8 feet high.
4 42856-01 • 01/30/09 • Hunte r Fan Company T o install a ceiling fan, be sure you can do the following: • Loc ate the c eiling joist or other suitable suppor t in ceiling. • Drill hole s for and install woo d screws. • Identif y and connect ele ctrical wires.
5 42856-01 • 01/30/09 • Hunte r Fan Company Steps 2-4 – 2-6 CAU TION: T o avoid possible elec trical shock , before installing your fan, disconnect the p ower by t urning o the circuit br eakers t o the outlet box and asso ciated wall switc h loc ation.
6 42856-01 • 01/30/09 • Hunte r Fan Company W ARNING: Fan m ay fall if not ass embled as direc ted in these installation ins tructions. 3-1. Lift the motor assembly and ho ok the three tabs over the handles, one at a time.
7 42856-01 • 01/30/09 • Hunte r Fan Company Dual Switch Wiring Single Switch Wiring All wiring must b e in accorda nce with national and lo cal ele c trical code s and ANSI/NFP A 70. If you are unf amiliar wi th wiring , us e a qualifie d elec trician.
8 42856-01 • 01/30/09 • Hunte r Fan Company 5-1. Place the fan housing over the mot or . 5-2. Raise the trim ring to allow access to t he holes on the ceiling plate. No te : Let the trim ring r est sitting diagon ally on ceiling plate to keep t he trim ring out of the wa y while installing the canopy sc rews.
9 42856-01 • 01/30/09 • Hunte r Fan Company Hunte r fans us e several styl es of fan blad e irons (brack ets that hold the blade to the fan). 6-1. Y our f an may inc lude blad e grommets. If your f an has grommets, insert them by hand int o the holes on the blad es.
10 42856-01 • 01/30/09 • Hunte r Fan Company Y our Hunter fan comes with an int egrated light xt ure assembly and an optional swit ch housing cap and plug b utton. i s feat ure gives you the option of installing the fan with OR without t he included light xtur e.
11 42856-01 • 01/30/09 • Hunte r Fan Company Lower Swit ch Housing Plug Connector Housing Ass embly Screw Plug Connector Detail Steps 7-6 – 7-7 7-6. T o attach the lower swit ch housing , connect the upp er plug connector from the motor to t he lower plug connec tor in the lower switc h housing as sembly .
12 42856-01 • 01/30/09 • Hunte r Fan Company 7 • Completin g Y our Instal lation With or Witho ut a Bow l Lig ht F i xtur e ( Contin ued) Installing the Gl ass Bowl 7-8. First install included B10 (60 W atts Ma ximum) bulbs into the sockets. 7-9.
13 42856-01 • 01/30/09 • Hunte r Fan Company 7 • Completin g Y our Instal lation With or Witho ut a Bow l Lig ht F i xtur e ( Contin ued) Uninstalling the Lig ht Fixture 7-17. T o uninstall the light xt ure, rst disconnect the plug connec tors betw een the black wire and t he red wire.
14 42856-01 • 01/30/09 • Hunte r Fan Company In warm weather , us e downward air ow patt ern In cold weather , us e upward air ow pattern 8-1. T urn on elec trical power to the fan. 8-2. e fan pull chain contr ols power to the fan. e pull chain has four settings in se quence: High, Medium, Low and O.
15 42856-01 • 01/30/09 • Hunte r Fan Company Problem: No thing happens; f an do es no t move. 1. T urn power on, replace fuse , or reset break er . 2. Loos en canopy , check all connections accor ding to the wiring the fan se ction. 3. Check the plug connection in the switch housing.
Een belangrijk punt na aankoop van elk apparaat Hunter Fan 42856-01 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hunter Fan 42856-01 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hunter Fan 42856-01 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hunter Fan 42856-01 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hunter Fan 42856-01 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hunter Fan 42856-01 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hunter Fan 42856-01 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hunter Fan 42856-01 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.