Gebruiksaanwijzing /service van het product P/N 406928 van de fabrikant hussman
Ga naar pagina of 29
Eur o Deli Ser vice Mer c handiser s Delicatessen Merchandisers (Includes W edge Installation) Installation & Operation Manual Shipped With Case Data Sheets P/N 406928.
INST ALLA TION Location . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Front Glass Caution . . . . . . . . . . . . . . . . . 1-1 Shipping Damage . . . . . . . . . . . . . . . . . . . 1-2 Exterior Loading . . . . . . . . . . . . . . . . . . . .
LOCA TION These merchandisers are designed for displaying products in air conditioned stores where tempera- ture is maintained at or belo w 75°F (24°C) and relati ve humidity is maintained at or belo w 55%. Placing refrigerated merchandisers in direct sun- light, near hot tables or near other heat sources could impair their ef ficienc y .
SHIPPING D AMA GE All equipment should be thoroughly examined for shipping damage before and during unloading. This equipment has been carefully inspected at our factory . An y claim for loss or damage must be made to the carrier . The carrier will pro vide any necessary inspection reports and/or claim forms.
LEVELING Merchandisers must be installed le vel to ensure proper operation of the refrigeration system and to ensure proper drainage of defrost water .
JOINING INSTR UCTIONS Sectional construction means that two or more merchandisers may be joined in line yielding one long continuous display requiring only one pair of ends.
REFRIGERANT The correct type of refrigerant will be stamped on each merchandiser’ s serial plate. The case refrig- eration piping is factory sealed, pressurized and leak tested. Before making refrigeration hookups, depress uni versal line v alve to ensure that coils hav e maintained pressure during shipment.
INSULA TION The suction and liquid lines should be clamped or taped together and insulated for a minimum of 30 ft (9144 mm) from the merchandiser . Additional insulation for the balance of the liquid and suction lines is recommended where ver condensation drippage is objectionable or lines are exposed to ambient conditions.
CONTR OL SETTINGS Merchandiser data sheets are shipped with this manual. The data sheets pro vide case control settings and defrost data. An e vaporator pressure re gulator or EPR (primary control) and a 3 – 5ºF (1.7 – 2.7ºC) dif ferential thermostat (secondary control) must control refrigeration temperature.
MERCHANDISER ELECTRICAL D A T A Merchandiser data sheets are shipped with this manual. The data sheets pro vide case electrical data, electrical schematics, parts lists and performance data. Refer to the merchandiser data sheets and case serial plate for electrical informa- tion.
W ASTE OUTLET AND W A TER SEAL The waste outlet is located in front of the fan plenum 6 ft (1829 mm) from the left-hand of the merchandiser (facing case front) allo wing drip piping to be run under the fixture lengthwise. A 1 1 / 2 in. (38 mm) water seal is supplied with each fixture.
INST ALLING SPLASHGU ARD AND LO WER FRONT P ANEL Make certain that the end assemblies, end splashguards and end panels ha ve been installed according to the End Kit instruction.
P/N 406928 3-3 E E u u r r o o D D e e l l i i M M e e r r c c h h a a n n d d i i s s e e r r s s HUSSMANN CORPORA TION • BRIDGETON, MO 63044-2483 (Printed in U.
INST ALLING BO TT OM REAR P ANEL For f ixed installation: 1. Align slots in bottom rear panel with center of legs. 2. Dri ve a he x head sheetmetal scre w through each slot into each leg.
ST AR T UP See the specific merchandiser's Data Sheet Set for refrigerant settings and defrost requirements. Bring merchandisers do wn to the operating temperatures listed on the data sheet. Each 4 ft (1219 mm) section has its o wn e v apora- tor coil and pre-set non-adjustable thermostatic expansion v alv e (TEV).
LO AD LIMIT PR OFILES 4-2 S T ART UP / O PERA TION P/N 406928 Load Limit ED1 Load Limit EDS1.
CARE AND CLEANING Long life and satisfactory performance of an y equipment is dependent upon the care it recei ves. T o ensure long life, proper sanitation and mini- mum maintenance costs, these merchandisers should be thoroughly cleaned, all debris removed and the interiors washed do wn, at least weekly .
INTERIOR CLEANING STEPS STEP 1 – Remove pr oduct to cooler . STEP 2 – T urn off r efrigeration. STEP 3 – Shut power off . STEP 4 – Remove display pans. STEP 5 – Lift out discharge air grille. STEP 6 – Lift out interior back panel. 5-2 M AINTENANCE P/N 406928 Do NOT allow product to sit in a non-refrigerated area.
STEP 7 – Lift out retur n air grille (from fr ont). STEP 8 – Rotate fan plenum up and back; hook chain at rear of liner . OR Unplug fan harness. Lift fan plenum up and back to remo ve.
STEP 9 – Clean inside the merchandiser . Once interior parts hav e been remov ed, collect loose debris for remov al. Do not clog waste outlet. STEP 10 – Clean and sanitize according to local requir ements. STEP 11 – Reassemble in re verse order .
REPLA CING F AN MO TORS AND BLADES See cross section for location of e vaporator f ans. Should it e ver be necessary to service or replace the fan motors or blades be certain that the fan blades are re-installed correctly .
For access to ambient f ans: 1. T urn of f power . 2. Remo ve lo wer front panel. 3. Disconnect f an from wiring harness. 4. Remo ve scre ws holding motor and grille. 5. Replace f an motor and grille. 6. Reconnect f an to wiring harness. T urn po wer on.
REPLA CING FLUORESCENT LAMPS Fluorescent lamps are furnished with moisture resistant lamp holders and end caps. Lamps on lighted shelves ha ve plastic shields. Whenev er a fluorescent lamp is replaced, be certain to re- install the plastic shields and end caps.
REPLA CING ELECTR ONIC B ALLAST Lamp Ballast The lamp ballast are located in the race way , behind the back lo wer panel at the left-hand end of the merchandiser (facing rear of case). NO TE: The switch for the lamp is located in this panel. T o gain access: 1.
REPLA CING CYLINDERS — SINGLE P ANE GLASS When cylinders need to be replaced, the lifting force of the cylinder must be kno wn. The lifting force can be determined by the data printed on the cylinder being replaced. The follo wing shows the part number for the 300N and 400N cylinders.
6-6 S ERVICE P/N 406928 REPLA CING SINGLE P ANE FR ONT GLASS (Requires mor e than one person.) 1. Raise the front glass to open completely . 2. Loosen all set scre ws along the inside bottom of the glass clamp. Note: All cylinders do not ha ve to be remo ved to remov e the glass IMPOR T ANT When reinstalling glass, be certain that: 1.
REPLA CING GLASS HAND GRIP The hand grip is fastened to the curv ed glass as sho wn below . A 2 inch (51 mm) bead of silicone needs to be placed 3 inches (76 mm) from each end and in the center of the hand grip. The duct tape is placed on the glass to provide a tight f it.
REP AIRING ALUMINUM COIL The aluminum coils used in Hussmann merchan- disers may be easily repaired in the field. Materials are av ailable from local refrigeration wholesalers. Hussmann recommends the follo wing solders and technique: Solders Aladdin W elding Products Inc.
® T o obtain additional information or other support, contact your Hussmann representative. Please include the model and serial number of the product. The full product warranty is available from our website, www .hussmann.com Hussmann Corporation, Corporate Headquarters: Bridgeton, Missouri, U.
Een belangrijk punt na aankoop van elk apparaat hussman P/N 406928 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen hussman P/N 406928 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens hussman P/N 406928 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding hussman P/N 406928 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over hussman P/N 406928 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van hussman P/N 406928 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de hussman P/N 406928 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met hussman P/N 406928 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.