Gebruiksaanwijzing /service van het product 4SA van de fabrikant IBM
Ga naar pagina of 208
IB M H ard w ar e M ainte n an ce M an ual IB M PC S e rv e r/E n t e rp rise R a c k s.
.
IBM H ard war e M aint en an ce M an ual IB M PC S e rv e r/E n t e rp r is e R a c k s.
No te : Bef ore usi n g this info rm atio n and th e produ ct it su pp orts , be sure to read th e gen e ral information under “ No t i ce s ” o n pa ge 1 95.
© Co pyright I BM Co rp. 2001 iii About this supp lem ent This s upplement contains diagnostic a nd service information for the IB M PC Ser ver Ra ck Enclos ur e and the I BM Rack e nc l osur es: IB .
iv Hardwa re Ma intenan ce Manu al: IBM PC Server /Enter prise Ra cks For inform atio n about See pu bl icatio n P C Se rv er s I BM P C Se rv er s H ard w are M a in te n an c e M an ua l (S30H -250 .
© Co pyright I BM Co rp. 2001 v Contents About this supplement . . . . . . . . . . . . . . . iii Re lat ed pu b lica tion s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii IBM PC Serv er/Enterpris e rac k enc losures 1 Gen era l ch ec kou t .
vi Har dwar e Ma int enanc e M anu al: IB M PC Serve r/E nterp rise R acks Li ne co rds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5 Po wer ca bles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5 NetBA Y server dua l -c or d Power Distribu tion Unit int rodu ctio n .
© Co pyright I BM Co rp. 2001 1 IBM PC Ser ver/Enterprise rack enc l osures Gen e ral c he ck ou t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Po wer c heck ou t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Po wer ing of f th e rac k .
2 Hardware Maintenance Manual: IBM PC Server/Enterprise Racks b. Server selector cable (connects between the server selector keypad and the se r ve r select or unit).
IBM PC Server/Enterprise rack enclosures 3 • Y es: Power-o ff t he server rack and r eplace the server rac k components i n the follo wing or der until the probl em goes away . See “ Pow e rin g o ff th e ra c k ” on page 3. a. Pow e r di s tribut i on unit f use.
4 Hardware Mai ntenance Manual: IBM PC Server/Enterprise Racks.
© Co pyright I BM Co rp. 2001 5 T ype 9306 Mode ls 4QS, 4QX, 9QS, 9QX, 9TS, 9TX Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 IBM P C S erv er e xpa nsi on ra ck m ode ls . . . . . . . . . . 5 Loca ti on s . .
6 Hardware Mai ntenance Manual: IBM PC Server/Enterprise Racks Se r ve r sel ect or con so le T o r emove th e Server Selector Co nsole: 1. Power -of f th e rac k. 2. Use an 1/8-inc h allen wren ch to r emove sc r ews. 3. Disc onn ect t he ser ver sele ct or cab le fr om the back of th e ser ver se le cto r cons ole.
Type 93 06 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 7 Conn ect i o ns P owe r dis trib ution un it No te: For infor matio n and inst alla ti on ins tr ucti ons for the IBM NetBA Y Rack Power Distr ib u ti on Units , see “ Net B A Y Pow er Di stri buti on Units ” on page 141 ".
8 Hardware Mai ntenance Manual: IBM PC Server/Enterprise Racks No te: These screws ar e held in place by nuts and washers. Hold the n ut while you ar e unscrewing the screw to preven t the nut and w asher fro m f alling in to th e bott om of the cab i net.
Type 93 06 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 9 Slid i ng tra ys Models 4QS and 4QX come wit h either single latc h slid e rai ls or d ual lat ch s lide rails. Single latch s lide rails have a front lat ch release o n the r ight rail only . D ual la tch sl ide rails ha ve a front latch rele ase on bo th rails .
10 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Dual lat ch r ail tra y T o remove a slidin g tray wit h dua l latc h rails: 1. Power -of f th e rac k. 2. Open the rear door of the r ack c abinet and r em ove the pi n 1 t hat sec ures the s li d in g tray to th e cabl e man ageme n t ar m.
Type 930 6 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 11 No te: Y o u will need to adjust t he p osition of t he slid ing rail in o rder t o line up t he acce ss h oles o ver t he loc ations of t he sc re ws. K ey boar d tra y T o r emove the keyboar d tray: 1.
12 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s P arts l ist in g (T ype 9306 – 1 9- inc h ) Mode l s 9 Q S, 9T S and 9Q X, 9T X This parts listi ng i s for Mo.
Type 930 6 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 13 Index 19- Inch Rac k Enclosur e (T ype 930 6) FRU 1 Adapter P late Optio ns: PS/2 Ser ver 85 /95 76H 3733 Mo de l 300 76H 3734 Model 500, 700 7.
14 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 1-phas e NEMA L5 -3 0P line co r d (10 0-1 27 V ac) f or NetBA Y Front- end PDU 00 N 7722 1-phas e NEMA L6 -3 0P .
Type 930 6 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 15 Rack Enclo sure Ki ts ( T ype 9 306) FRU Bolt- T oge t her Kit (19- Inc h to 24- Inc h, 24 -I nch t o 19-In ch) • 19-Inc h Att achme nt Br ac.
16 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Miscellane ous Parts Kit • Rack Nut/H o lder 10- 32 (8 e ach ) • Keeper Nut 8-32 Zinc ( 8 each) • Keeper Nu.
Type 930 6 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 17 P ar t s listi ng (T yp e 930 6 – 24-in ch) M odels 4Q S, 4 QX Th is part s lis ting is for Models 4QS and 4Q X.
18 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Index 24-I nch Rack Enclosure (T ype 9 306 ) FRU 1 Adapter Plate O ptions: PS/2 S erver 85/9 5 76H 3733 Model 300.
Type 930 6 M od e ls 4QS, 4Q X, 9QS , 9QX, 9 TS , 9TX 19 20 Leveling Feet (Qty . 4) 07H 0053 21 Stabiliz ing Leg 07H005 1 22 Keyb oar d Dra w er , 24-Inc h (wit h Sl i de s an d Bracke ts) 07H00 77 23.
20 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s.
© Co pyright I BM Co rp. 2001 21 T ype 9306 Model 200 Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Loca ti on s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Side pan el . . . . . . .
22 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Se lec to r s wi tch locat ions No te: For infor mat ion abou t t he I BM Net B A Y C onsole Swi tch , se e “ IBM NetB A Y co ns ole swi tc h ” on page 129. Fi gure 1.
Type 930 6 Mod e l 200 23 Figure 2. Selector s witch between side panels Figure 3. Selector s witch rear of rack with blank panel front of rac k FRONT REAR One K M Three K M K M Two Aux.
24 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Selec tor swit ch cab le connectio ns Tier ed s wi tch co nfigu ration One eight-port primary selec tor switch can accommodat e up to eight secondary sele ctor switches which can then support up to 64 servers.
Type 930 6 Mod e l 200 25 Selec tor s wit ch en vironm ent Figure 4. Single selector switch Fig ur e 5. Mu lti ple s ele c t o r switch Monitor Keyboard Mouse Selector Switch Server 1 Server 2 Server .
26 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s P ower Di stributio n Unit No te: For infor matio n and inst alla ti on ins tr ucti ons for the IBM NetBA Y Rack Power Distr ib u ti on Units , see “ Net B A Y Pow er Di stri buti on Units ” on page 141 .
Type 930 6 Mod e l 200 27 No te: There ar e two t ypes of Power distribution units available: • Hig h v ol ta ge • Lo w vo l t ag e Bl ank b ez el Fix e d shel f.
28 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s K ey boar d tra y T o r emov e th e tray fr om the si d e rail s, pull up on the le ft rai l tab and pu sh down on th e rig h t ra il ta b .
Type 930 6 Mod e l 200 29 In stal li ng a fl at pane l m o ni tor r a c k m oun t kit Y ou can st or e a T54 or T55 Flat P an el Monitor in a keyboar d tray with th e f l at panel monit or rack mount kit. This kit req uir es an addi tional 2U of space above an inst all ed key b oar d tray in yo ur rack cabin et.
30 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 1. Unplug the flat panel m o nit or and disconnect the power cord fr om the flat panel monitor pow er supply . 2. Carefully use a flat-blad e scr ewdriver to pry the bo t to m of the cable cover 1 up and r emove it.
Type 930 6 Mod e l 200 31 Figure 1 1. Removing t he ex isting monitor stand from t he monitor 7. Lift of f th e hinge a n d monitor stan d assembl y . S tor e this assembly in a safe pl ace for possible futur e use.
32 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Figure 13. Installing the hinges on the flat panel monit or No te: Be sure to slide eac h hinge into place on the back of the m onit or and align the holes in the h inges with holes on the m onit or .
Type 930 6 Mod e l 200 33 Figure 1 5. Installing the flat p anel mo nitor in t he ke yboard tray No te: Clean the installat ion area on the keyboard tray with a suitable clea ning agent , such as alcohol, before insta lling the rubber bumpe rs on the front of the k e ybo ard tray .
34 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Figure 1 6. Stor ing the p ower supply an d routing c ables 8. Connect the pow er suppl y to the monitor and rout.
Type 930 6 Mod e l 200 35 Figure 18. Routing the k eyboard cabl e 14. Route the s pace-saver keyboar d cable thro ugh the hole in t he fr ont of the bas e and out the opening in the back where you removed the small cover; then, place the keyboa r d ( with it s adju stable feet full y dow n) ins ide the keybo ard tray .
36 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Switc h con figuratio n can be p erformed to: • Ass ign uniq ue n ame s to ser vers. • Disp l ay ser vers b y thei r assi gned por t name s an d por t numbe rs.
Type 930 6 Mod e l 200 37 • Using the Up Arrow ( a nd Down Ar ro w ( ) , select the server you want to switch to, or press the numeric key that corre s ponds to the server ’ s port number and t hen pr ess Enter .
38 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Scan ning t he server s T o place the selector swi tch in scan mode: • Pres s the Print Screen ke y • Pres s the F2 key to d is p la y the Advanced Menu screen.
Type 930 6 Mod e l 200 39 — Enable d o r disa bled — Sa mple rate — Res oluti on — Mouse type • Pres s Esc to re m ove th e V e rsion men u .
40 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s If Na me order w as s elected, the Po rt and Nam e colum ns w ill be reversed. 4. Using th e keyboar d key s, select the port number of the first server to be in cl uded in t he scan.
Type 930 6 Mod e l 200 41 4. Move the highlighting t o the Port entry fo r which the s erver name is to be enter ed or changed. T ype in t he name of the ser ver using up t o 12 a lphanumeric ch ara cte rs. No te: Legal charac ter s are A-Z, 0-9, and the dash charact er .
42 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s • Highligh t the settings yo u want t o change a nd use the + or - keys to c hange the values. As yo u select dif fer en t values, the effec t of the c hanges is refl ect ed immediat el y on the display .
Type 930 6 Mod e l 200 43 Ch anging the st atus fla g attrib utes The st atus flag shows the c urr ently connected server and can be set t o appear on t he screen whenever the system is operating.
44 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 4. Hi ghlight the setting to be changed and use the + and - keys to adjust the valu es. The following table describes each of the available menu a ttri butes : 5. Press the Ent er key to save the settings.
Type 930 6 Mod e l 200 45 4. T o assign a monitor type, h ighli g ht the port you want and use the + or - keys to sele ct the value that corr esponds to the particular monitor . T o as sign a sec ondar y selec tor s witch to a port, h i ghligh t t he por t and us e the + or - keys to o bt ain the appropri ate port value.
46 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Maki ng co nnecti ons un de r po wer Addit ional s erve rs, can be co nnected to the selec tor swit ch w hile the selec tor sw itch is running. Fai led devic es su ch as a ke yboar d or mou s e ca n be con nect ed to a run ning sele ct or sw itch .
Type 930 6 Mod e l 200 47 P ar t s List in g (T yp e 93 06 Mode l 2 00 ) 1 2 3 5 6 7 8 9 4 10.
48 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Index Rack Enclos ure (T ype 9 306 M odel 2 00) FRU 1 T o p C ov er i nc lu din g c ov er st an d o f fs an d sc .
Type 930 6 Mod e l 200 49 V ideo , Mouse, Keyboar d Cable (12 feet) 06P6007 V ideo , Mouse, Keyboar d Po wer Cable (25 feet) 12J4484 Mouse Ext e nsi o n Cable 07H 0069 Keybo ar d Extensi o n Cabl e 07.
50 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s.
© Co pyright I BM Co rp. 2001 51 T y pe 9306 Mode l 900/910 Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Loca ti on s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Side Pan el . . . .
52 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s P e rf orated Door s (mo del 910) The T ype 9306 Model 910 Rack comes wi th fr ont and r ear perforat ed doors that pro vid e enhanced cooling and airflow for components you i ns tall in your rack cabi n et.
Type 93 06 M od e l 900/ 910 53 Ref e r to i n stal lation in st ructio n s in th is documen t if you hav e a 9306 Model 90 0 Rack and are ins talling a ne w pe rforat ed front doo r . No te: The illustrat ions in th is docu menta tion m ight be slig htly d if fer en t from you r hardw a re.
54 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s No te: Inse r t the s c r e w thro ugh t he brac ket an d int o the l owe r o f th e t w o hol es in the ne w center locat ion. 5. Re m o ve t he ot her hi n g e br ac ke t 3 and s t ore it w it h t he ol d d o or th at yo u re m o ve d e a r l i e r .
Type 93 06 M od e l 900/ 910 55 Figure 2 0. Selector switch be tween s ide panel s Figure 2 1. Selector switch rear of rack with blank pane l front o f rac k FRONT REAR One K M Three K M K M Two Aux.
56 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Selector switch cable connections: T iered switch configuration: One eight-port primary selec tor switch can accommodat e up to eight secondary sele ctor switches which can then support up to 64 servers.
Type 93 06 M od e l 900/ 910 57 Selector switch envi ronment : F i gur e 22 . Si n g l e se l ec tor s wi tch Fig ur e 23 . M ult ip le s e lec t or switc h P ower Dist ribut ion Unit No te: For infor.
58 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s F i gur e 24 . P o w e r D is tri b u t i on i n sta l l ati on Figure 25.
Type 93 06 M od e l 900/ 910 59 Blan k bezel Fixe d sh el f.
60 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Key bo a rd tr ay T o r emove the tray f r om the si de rai ls, pull up on the le ft rai l tab and push down on th e rig h t ra il ta b .
Type 93 06 M od e l 900/ 910 61 Insta lling a f lat pan el moni tor rac k mou nt kit Y ou can st or e a T54 or T55 Flat P an el Monitor in a keyboar d tray with th e f l at panel monit or rack mount kit. This kit req uir es an addi tional 2U of space above an inst all ed key b oar d tray in yo ur rack cabin et.
62 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 1. Unplug the flat panel m o nit or and disconnect the power cord fr om the flat panel monitor pow er supply . 2. Carefully use a flat-blad e scr ewdriver to pry the bo t to m of the cable cover 1 up and r emove it.
Type 93 06 M od e l 900/ 910 63 Figure 2 9. Removing t he ex isting monitor stand from t he monitor 7. Lift of f th e hinge a n d monitor stan d assembl y .
64 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Figure 3 1. Installing the hi nges on t he fl at panel m onitor No te: Be sure to slide eac h hinge into place on the back of the m onit or and align the holes in the h inges with holes on the m onit or .
Type 93 06 M od e l 900/ 910 65 Figure 3 3. Installing the flat p anel mo nitor in t he ke yboard tray No te: Clean the installat ion area on the keyboard tray with a suitable clea ning agent , such as alcohol, before insta lling the rubber bumpe rs on the front of the k e ybo ard tray .
66 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Figure 3 4. Stor ing the p ower supply an d routing c ables 8. Connect the pow er suppl y to the monitor and rout.
Type 93 06 M od e l 900/ 910 67 Figure 36. Routing the k eyboard cabl e 14. Route the s pace-saver keyboar d cable thro ugh the hole in t he fr ont of the bas e and out the opening in the back where you removed the small cover; then, place the keyboa r d ( with it s adju stable feet full y dow n) ins ide the keybo ard tray .
68 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Switc h con figuratio n can be p erformed to: • Ass ign uniq ue n ame s to ser vers. • Disp l ay ser vers b y thei r assi gned por t name s an d por t numbe rs.
Type 93 06 M od e l 900/ 910 69 • Using the Up Arrow ( and Do wn Arr ow ( ), selec t the se r ver yo u want to switch to, or press the numeric key that corre s ponds to the server ’ s port number and t hen pr ess Enter .
70 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s • Pres s the F2 key to d is p la y the Advanced Menu screen. • Using the Up Arrow ( ) and Do wn Arr ow ( ) keys, move the highlighting to Sca n and press En ter .
Type 93 06 M od e l 900/ 910 71 Sa vi ng ha rd wa re c o n f ig ura ti o n : Whenever servers ar e added to or removed fr om the configuratio n, or w henever ther e is a change in the mouse or mo nito r , save the hardware configuration setting by: 1.
72 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s length o f time yo u want this server to be connected t o the monitor and keyboard, before sw itchin g to th e next server in th e scan. 6. Press the Down Arrow ( ) key to m ove the h ighlighting t o the n ext port in the Port column and repeat step 5.
Type 93 06 M od e l 900/ 910 73 Changing menu at tributes : T he me nus di splayed o n the moni tor can be alte r ed in visual a ppear ance to suit the particular use of the syst em. Y ou c an: • Position the menu in a convenie nt locati on on t he dis play .
74 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 4. F10 5. Y 6. Enter A va ilable m enu attribut es: Changing t h e st atus fla g attrib utes: The status flag shows t he current ly connected server and can be set t o appear on the screen whenever the system is operating.
Type 93 06 M od e l 900/ 910 75 4. Hi ghlight the setting to be changed and use the + and - keys to adjust the valu es. The following table describes each of the available menu a ttri butes : 5. Press the Ent er key to save the settings. Press Esc at anytime befo r e pre ssing Enter to cancel the operation and save the pre v ious settings.
76 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 4. T o assign a monitor type, h ighli g ht the port you want and use the + or - keys to sele ct the value that corr esponds to the particular monitor .
Type 93 06 M od e l 900/ 910 77 P ar t s listi ng ( T ype 9 30 6 Mod el 900/9 10 ) 1 10 11 2 3 4 5 6 7 8 9.
78 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Index Ra ck Encl os ure ( T ype 9306 Model 900/910 ) FRU 1 T op Cover incl u ding co v er stando ffs an d scr e w.
Type 93 06 M od e l 900/ 910 79 Fi l l er Pan e l s: 1U , 3U, and 5U - with Ha rd w ar e 12J4 473 Keyboard T r ay 76H49 58 Keyboard T r ay II 28 L0 56 2 Keyboard T ray II filler block 28L0567 Ke y bo .
80 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s.
© Co pyright I BM Co rp. 2001 81 NetB A Y 42 Enterp rise Rack (T ype 9308 Model s 42P , 42X, 4S A, 4SB, 42 S, 42E ) Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Loca ti on s . . . . . . . . . . . . . . . . . .
82 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Primar y Rack (M odel 42P ).
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 83 Exte ns i on R ac k (Mo d e l 42 X).
84 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Primar y Rack (42S).
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 85 Expa nsi on R ac k (4 2E) Loc ati ons Th e follow ing s ectio ns cont ain informa tion on spe cific equ ipm ent lo cation s. Re moving and inst all ing p an els The prim a ry rack cabi net co mes wi th si d e panel s in sta ll ed.
86 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Figure 37. Removing the r ack side panels 1. From t he inside o f the r ear of the rack cabin et, slide the side panel lock ing bar towar d t he unlocked position. 2.
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 87 Figure 38. Removing the t op 6U side panels from the rac k cabinet 1. On the top o f the rack cabinet, loo sen the four scr ew s that hold each side panel in place.
88 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Front a n d rea r do ors – Model s 42P , 42X, 4SA, 4SB T o r emove a door: 1. Unlock the door and open it fully . 2. Gras p the door 1 firm ly wi th both hands an d lift it upwards unti l it is ful ly off of t he hinges 2 .
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 89 Re ar do or – Mod els 42S , 42E Use the following procedur e to remove a rear door from the rack cabinet: Figure 39. Removing a rear door f rom the rac k cabinet 1.
90 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Front d oo r – Mode ls 42S, 42 E Use the following procedur e to rem ove a front door from the rack cabinet: Figure 40.
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 91 1. Unlock and open the front door . 2. While supp orting the do or , lift the b ottom hi nge-pin latch a nd m ove it clock wise to unlock the bo t tom hinge pin; then, unlock t he top hinge pin.
92 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 2. Remove the 16 screws (eight per side) that hold the top 6U portion of the rack cabin et in place. 3. Relocate your r ack c abinet; t h en, inst all t he top 6U portion o f the r ack cabinet using al l 16 of the scr e ws t ha t you re move d.
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 93 Figure 42. Attaching two adjacent rack cabin ets to each other to f or m a suite 1.
94 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 5. Snap the trim pieces into place between the adjacent rack cabinets. Install one trim piece in the fr ont a nd one in t he r ear . 6. Repeat step 3 through step 5 for all other adjacent r ack cabinets in the suite.
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 95 No te: U se cli p nuts if you r ra ck ha s hol es. If you r rac k has sq ua re hol es , yo u ca n use th e rac k- i nsert ion t ool or a flat- blade sc r ewd ri ve r to inst all c ag e nuts .
96 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s 6. Loos ely in ser t on e M5 scr ew 1 in to e ac h r ai l. 7. Slide the expansio n u nit into the r ack, a nd ins ert th e M6 screws 1 . Do not ov e rt i g h te n th e M 6 1 s crew s.
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 97 8. Tigh te n th e re ar sc rew s 2 . Ins tal ling a se rv er A smal l serv e r can occu p y fr om 1U to 5U of rack mou n tin g spac e . A la r ge s e rv er ca n occ upy 8U or mor e of r ack mou ntin g space .
98 H a r dw ar e Mai nte nance Ma nu a l: I B M P C Se rv e r/ E nt e rpr i se R ack s Insta lling a la rge se rver Use the following general pr ocedure to instal l a large ser ver in your rack cabin et: Figure 43. Installing a large se r ver 1. See t he se rver docume ntation for d etailed inst allation and conf iguratio n inform ation.
Ne tBAY 42 Ent er pr i s e Rack (Ty p e 9308 Model s 42P , 42 X, 4S A , 4S B, 42 S, 42E ) 99 Insta lling a sm all server Use the following gener al pr ocedure to install a small server in your rack cabin et: Figure 4 4. Installing a small ser ver 1. See t he se rver docume ntation for d etailed inst allation and conf iguratio n inform ation.
100 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Fix e d shel f No te: A fixed shelf can suppor t a devic e or option weighi ng up to 45kg (100 lbs ) . T o install a fixed shelf: 1. Determine the location for the fixed shelf within the rack.
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 101 K ey boar d tra y T o i nstall a keyboard tray: 1. Secure the slide rails to the front 1 and rear 2 of th e ra c k , ad j u st i ng th e m a s needed. 2. Slide the keyboard tray onto the rai l s and stor e the keyboar d 3 in the ar ea pro vided.
102 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Mo ni to r shel f T o install a monitor shelf: 1. S ecu re t he re ar m on itor sh e lf b rac ke t in th e rear of th e r ack 1 with two sc rews per s ide.
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 103 In stal li ng a fl at pane l m o ni tor r a c k m oun t kit Y ou can st or e a T54 or T55 Flat P an el Monitor in a keyboar d tray with th e f l at panel monit or rack mount kit.
104 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 1. Unplug the flat panel m o nit or and disconnect the power cord fr om the flat panel monitor pow er supply . 2. Carefully use a flat-blad e scr ewdriver to pry the bo t to m of the cable cover 1 up and r emove it.
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 105 Figure 4 8. Removing t he ex isting monitor stand from t he monitor 7. Lift of f th e hinge a n d monitor stan d assembl y . S tor e this assembl y i n a safe pl ace for possible futur e use.
106 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 5 0. Installing the hi nges on t he fl at panel m onitor No te: Be sure to slide eac h hinge into place on the back of the m onit or and align the holes in the h inges with holes on the m onit or .
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 107 Figure 5 2. Installing the flat p anel mo nitor in t he ke yboard tray No te: Clean the installat ion area on the keyboard tray with a suitable clea ning agent , such as alcohol, before insta lling the rubber bumpe rs on the front of the k e ybo ard tray .
108 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 5 3. Stor ing the p ower supply an d routing c ables 8. Connect the pow er suppl y to the monitor and route the cable unde.
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 109 Figure 55. Routing the k eyboard cabl e 14. Route the s pace-saver keyboar d cable thro ugh the hole in t he f.
110 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks T o install a blank filler panel: 1. Determine the size ( 1U, 3U, o r 5U) pa nel you need .
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 111 P ar t s listi ng ( T ype 9 30 8 Mod el 42P , 42 X) Index Rack Enclos ure ( T ype 9 308 M odel 4 2P , 42 X, 4S.
112 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Leveling f oot wrenc h (All models) 05N4927 Rac k Encl osure (T ype 9308 M odel 42P , 42X, 4 SA, 4SB, 42S, 4 2E) Opt ions FRU Mon.
Net BAY 42 Ente r pr is e Rack (Type 93 08 Models 42 P, 42 X, 4SA , 4S B, 42 S, 42E ) 113 Flat Panel Adapter Display Housing – I ncl ude s: Pow er Sup p ly Cov er (1 ) ; Ba se Ho usin g (1) ; Cab l .
114 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
© Co pyright I BM Co rp. 2001 115 NetB A Y3 enc losure Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 5 Loca ti on s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 5 Cas ter s . . . . . .
116 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Ca sters • T wo fi xed cast ers 1 at the f r ont of th e NetBA Y3 encl osu r e.
NetB AY3 en clo s ure 117 Fr ont co ver Rea r pa ne l No te: Make sur e empty NetBA Y3 enclosures (no devices instal l ed) have the rear co ver se cur ely att ache d.
118 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Devi ce sid e rails St acking Ne tBA Y3 en c lo sur es No te: Make sur e NetB A Y3 enclos ur es in a stack are se c ur ely f aste n ed tog ether .
NetB AY3 en clo s ure 119 No te: The ma xi mum se rv er weig h t i s 7 7 kg (1 7 0 lb. )..
120 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
NetB AY3 en clo s ure 121 P ar t s List in g (N etBA Y 3) Index NetBA Y3 Enc losur e (NetBA Y3) FRU 1 3-U Encl osu re Fr ame 0 3K879 7 2 Fro nt Bezel A ss embl y with Lock and K eys 03K 879 8 3F o o t P a d s Q t y . 4 03K 8800 4 Cast ers Fixed, Fro nt, Qty .
122 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
© Co pyright I BM Co rp. 2001 123 NetB A Y3E e nc losure Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3 Loca ti on s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3 Cas ter s . . . . . .
124 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Ca sters • T wo fixed cast ers 1 at t he fr ont of t he NetB A Y3E enc losur e.
Net B AY3E e nc los ur e 125 Rea r pa ne l No te: Make sur e em pty N etBA Y3E e nclosur es (no d evic es i nstall ed) hav e th e r ear co ver se cur ely att ache d.
126 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Devi ce sid e rails St acking Ne tBA Y3 E en closu res No tes: 1. Make sur e NetBA Y3E enclosur es in a stack are sec u r ely fastened together .
Net B AY3E e nc los ur e 127 No tes: 1. The maxi mum server weight is 77 kg (170 lb.). 2. Always install a server on the to p enclosur e in a st ack. Carefully lift the ser ver by it s handle s an d alig n its mo unting h oles 1 wi th th e NetB A Y3E encl osure mo u nt ing stud s 2.
128 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
© Co pyright I BM Co rp. 2001 129 IBM NetB A Y conso le swi t ch Fe ature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 0 T o ol re qu irem ent s . . . . . . . . . . . . . . . . . . . . . . . . . . 1 31 Sp ecif ic atio ns .
130 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks No te: A NetBA Y Co nsole Ca ble S et is r eq uired for each server that you will connec t to a con sole sw itch, o r for ea ch c onsole s witch you w ill connect to anot her console switch in a tier ed conf i g urat ion.
IBM N etBAY con sole swi tch 131 Y ou can conn ect multiple cons ole s witch es to each other in a tiered configurat i on. If you use a 1x4 Console Switch as the primary sw itch, you can connect up to four add itional c onso le swi tches and 32 s ervers.
132 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks • A Phillips screwd riv er • A 10mm nu t driver or 10mm open-end o r box wrenc h Spe cifica tion s The foll owing tabl e cont.
IBM N etBAY con sole swi tch 133 No te: Remo vin g t he ra ck do ors and s ide pan els mig ht ma ke yo ur con s ole s wit ch instal lat ion ea sier . 2. If the m onit or shelf is not a lr ead y insta lled, ins tall t he mo nitor s helf according t o its docum ent a tion.
134 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 6. Con nect the moni tor signal cabl e f r om y our mo n itor t o th e bl ue monitor connect or on Por t A of the c o nsole switch; then, tighten the screws on the monitor si gna l c a ble .
IBM N etBAY con sole swi tch 135 1. Refe r to th e do cumen ta t i on th a t c omes wi th y ou r rack cabi net for add iti onal inform ation. No te: Rem oving t he ra ck door s and s ide pan els migh t make y our con sole swi t ch instal lat ion ea sier .
136 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 4. V erify that the power switch on the rear of the console switch is in the Off position before co nnectin g any cables.
IBM N etBAY con sole swi tch 137 15. Refer to the Apex User Guide C D for configurati on and operat i on informat ion ab out y our c o nsol e sw it ch.
138 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Continue with the rest of the procedure to cable your console switch. No te: Refer to the Apex User Guide CD f or additional informatio n if you are con figuring a tiered installat ion.
IBM N etBAY con sole swi tch 139 9. Connect one end of a console c able set t o one of the number ed ports on the r ear o f t he c onsol e swit ch. 10 . Route th e conso le cab l e set tow ar d the rea r of your ra ck cabi n et, a nd up or do w n to war d your ser ver .
140 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
© Co pyright I BM Co rp. 2001 141 NetB A Y P o wer Distrib ution Unit s NetB A Y rack Pow er Di str ib u ti on Uni t i ntr odu ct ion 141 T o ol re qu irem ent s . . . . . . . . . . . . . . . . . . . . . . . . . . 1 42 Ins tal lat io n o ver vi ew . .
142 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 4. Y ou can inst all othe r M/PDU fam ily devi ces next to your Rack PDU us ing mou n tin g h ardw are from bo th d evic es .
Net BAY Pow er Dist ribution Un its 143 No te: The mounting holes on the upper and low er side braces in a rack side compartment m ust be bet ween 48.6 cm (1 9.
144 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 6 0. Installing the ver tical mount ing pl ate and cable-management brack et 6. Inst all the ca ble-ma n age me n t br acket 1 beside the verti cal m oun t i n g plat e with fou r M 6 scre w s an d n u ts th a t com e wit h th is op t i o n .
Net BAY Pow er Dist ribution Un its 145 2. V er ify that the circuit breaker swit ch is in the Off po sitio n before insta lling your Rack PDU. 3. Inst all the hori zontal mounti n g bracke t 3 on one si de of the Rack PDU 5 with M3x5 screws 4 . No te: Ther e ar e two set s of mounti ng holes on the brac ket.
146 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 6. Inst al l t he 1U blank fil ler pan e l 1 on the f r ont of th e ra ck cabi n et at t he sam e U leve l a s th e Ra ck P D U. Use two M 6 scre w s th at co me wi th th is o pti o n .
Net BAY Pow er Dist ribution Un its 147 Figure 63. Installing th e mounting brack ets f or two devices 4. Push the two Rack PDUs together , aligning the holes o n the dual-device attac h ment brac ke ts; th en, us e four M6 sc re ws to se cur e the f r ont 1 and rear 2 of th e b ra ck ets to e ac h o th e r .
148 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 64. I n stalling two Rack PDUs and the b lank filler panel 7. Inst al l t he 1U blank fil ler pan e l 1 o n th e fron t of the ra ck c abi n e t at th e sa m e U leve l a s th e Ra ck P D U.
Net BAY Pow er Dist ribution Un its 149 Stateme nt 1 DA NGE R Stateme nt 13 To c o n n e c t : 1. T urn ever ything OFF . 2. F irst, atta ch all c ables t o devi ces. 3. A tta ch signal cable s to c onn ectors . 4. A tta ch pow er cords to outlet. 5. T urn d evi ce ON.
150 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks DA NGE R Cab li ng inst ructio ns f or ve r tical- mount P DUs If your R ack PDU cam e with more than one line cor d, sel ect either the high-voltage cord or the low-voltage cord for your installati on.
Net BAY Pow er Dist ribution Un its 151 2. Reinstall the scre w on the cable clamp 1 and repeat step 1 for the other device if you in stalle d tw o de vices.
152 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 67. Connecting and routing the line cord Reinstal l th e screw on t he cable clamp and r epeat this st ep for the other device, if you in stalle d tw o de vices.
Net BAY Pow er Dist ribution Un its 153 Figure 68. Connecting and routing other power cables to t h e outlets 7 7.
154 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Rac k PD U specifica tions When connected to a dedicated power source, t he R a ck PD U confo rms to UL950, CSA 22.0-9 50, EN-60 950, and IE C- 950 standar ds. The following ta ble contains th e pr oduct specifica tio ns for the Rack PDU: He ig ht 43 m m (1.
Net BAY Pow er Dist ribution Un its 155 P ower cabl es Power cables that you use to c onnect a sys tem, storage expansion uni t, and ot her dev ices t o t he R ack P DU us ua lly co me wi th tho se dev ice s.
156 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Lin e c o r ds A 4.3 m (14 f t) coun try-s pecif i c lin e cor d that you use to co nnec t y our Rack PDU to a pro perly wired , grounde d, and ded i cated pow er sour ce comes w i th t h e Rack PDU .
Net BAY Pow er Dist ribution Un its 157 • One vertical mounting plat e • One ve rtical-mounting ca ble-management br acket • Misc ellaneo u s har d war e kit (f or at taching brac k ets and inst.
158 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Stateme nt 1 DA NGE R 1. Refe r to th e do cumen ta t i on th a t c omes wi th y ou r rack cabi net for add iti onal inform ation. No te: Remo vin g t he rack doo rs an d s ide p anel s m ight ma ke your Ra ck PDU instal lat ion ea sier .
Net BAY Pow er Dist ribution Un its 159 Figure 69. Installing t he Rack PDU on the v er tical mount ing plate 3. Install the vertical mounting plate in the s i de of your r a ck cabinet with four M6 s cr ew s an d nuts th at c ome wi th thi s op ti on.
160 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 71. Routing the fix ed line cord and po wer cabl es 5. Route the lin e cor d towards a dedicated power source. Use the provided cable straps to secure the line cord along the w a y .
Net BAY Pow er Dist ribution Un its 161 Stateme nt 1 DA NGE R 1. Refe r to th e do cumen ta t i on th a t c omes wi th y ou r rack cabi net for add iti onal inform ation. No te: Remo vin g t he rack doo rs an d s ide p anel s m ight ma ke your Ra ck PDU instal lat ion ea sier .
162 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 72. Installing t he Rack PDU on the v er tical mounting plate 3. If you have a sec ond M/PDU d evice to ins tall, install it on t he ve rtical m ountin g pla te wi th fou r M 3 x5 scre w s th a t co m e w ith th e se co n d dev ic e.
Net BAY Pow er Dist ribution Un its 163 Figure 7 4. Installing the ver tical mount ing pl ate and cable-management brack et 5. Inst all the ca ble-ma n age me n t br acket 1 b esid e th e ver tic a l mo un tin g pla te w it h fou r M 6 scre w s an d n u ts th a t com e wit h th i s op t i o n .
164 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 7. Route each line cord towar ds a d edicated power sour ce. Use t he pr ovided cabl e straps to secure the line cords along the way . Use the openings in your rack cab in e t , i f yo u mu st ex it th e ra c k ca b in e t to co n ne c t to you r po w e r so ur ce.
Net BAY Pow er Dist ribution Un its 165 Line co rds The 2. 5 m ( 8.2 ft) f i xed line c ord o n the Rac k PDU determines the connect i vity of the Rack P DU.
166 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks NetBA Y ser ver dual -cord P o wer Di str ibution U nit in trodu ction Th e IB M N etB A Y Se rver D ua l-c ord P ow e r D istr i.
Net BAY Pow er Dist ribution Un its 167 No te: The illustrat ions in th is docu menta tion m ight be slig htly d if fer en t from you r hardw a re. T ool re qui rem en ts Y ou will n eed the follow in.
168 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 77. Installing t he Rack PDU on the v er tical mounting plate 3. If you have a sec ond M/PDU d evice to ins tall, install it on t he ve rtical m ountin g pla te wi th fou r M 3 x5 scre w s th a t co m e w ith th e se co n d dev ic e.
Net BAY Pow er Dist ribution Un its 169 Figure 7 9. Installing the ver tical mount ing pl ate and cable-management brack et 5. Inst all t he cable-manag ement br acket 1 besid e the v ertical m ounting pl ate w ith fou r M 6 scre w s an d n u ts th a t com e wit h th i s op t i o n .
170 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 2. Inst all th e h orizon tal moun ti ng brac k e t 3 on o ne side of the Rack PDU 5 with M3x5 screws 4 .
Net BAY Pow er Dist ribution Un its 171 Ins tal ling t wo devi ces h orizo ntal ly Use the following pr ocedure to mount two Rack PDU s horizontally in your rack cab inet : 1. Refe r to th e do cumen ta t i on th a t c omes wi th y ou r rack cabi net for add iti onal inform ation.
172 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 82. Installing th e mounting brack ets f or two devices 3. Push the two Rack PDUs together , aligning the holes o n the dual-device attac h ment brac ke ts; th en, us e four M6 sc re ws to se cur e the f r ont 1 and rear 2 of th e b ra ck ets to e ac h o th e r .
Net BAY Pow er Dist ribution Un its 173 Fig ure 83. Install ing the Rack PDUs and the blank filler panel 6. Inst al l t he 1U blank fil ler pan e l 1 on the f r ont of th e ra ck cabi n et at t he sam e U leve l a s th e Ra ck P D U. Use two M 6 scre w s th at co me wi th th is o pti o n .
174 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Stateme nt 1 DA NGE R Stateme nt 5 CAUTION: The power control button on th e device and t he power switch on the power supply do n ot turn of f the electric al cur rent supplied to the device.
Net BAY Pow er Dist ribution Un its 175 have m ore than one pow er cord. T o rem ove all electric al cu rren t from the d evice, ensur e that all p ower cor ds are disco nnected f rom the p ower source.
176 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks along the way . Use the openings in your r ack cabinet, if you m u st exit the r ack ca b i net to co n nec t to you r power sou r ce.
Net BAY Pow er Dist ribution Un its 177 Figure 86. Connecting and routing the line cords 2. Connect the other l ine cor d to the Bac kup inlet on the Rack PD U.
178 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Figure 87. Connecting and routing other power cables to t h e outlets.
Net BAY Pow er Dist ribution Un its 179 Rac k PD U spec ificatio ns When connected to a dedicated power source, t he R a ck PD U confo rms to UL950, CSA 22.0-9 50, EN-60 950, and IE C- 950 standar ds. The following ta ble contains th e pr oduct specific atio ns for the Rack PDU: He ig ht 43 m m (1.
180 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks P ow e r cab les Power cables that you use to connect a server (with more than one p ower supply) to the Rac k PDU usually come with t he server .
Net BAY Pow er Dist ribution Un its 181 Line co rds T wo 4. 3 m (14 ft) country-s peci fic line cords that you use to connec t your Rac k PDU to pro perly wired , grounde d, and ded i cated pow er sour ces come w i th t h e Rack PDU .
182 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
© Co pyright I BM Co rp. 2001 183 Related service inf ormation These pr o cedures ar e written w ith the as sumption that you have model-specific training on a ll com puter s, or t hat ar e familiar with the c omput ers, f unctions , term ino log y , and servi ce infor m atio n provided in this manu al.
184 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 1. PER IGO • O peso m á ximo permitido para dispositivos montados em trilhos é de 80 kg (176 lbs ). N ã o instale di spositivos em trilho s que excedam este pes o. • O ce ntr o de g ra vi da de pa ra u ma un ida d e est end id a n ã o pode ex ceder 3 62 mm (14.
R elate d servic e informa tion 185 1. DA NGE R 2. DA NGE R 3. DA NGE R 4. DA NGE R.
186 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 1. DA NGE R • Le po ids m ax ima l d' une u nit é mont é e sur glis si è res es t de 80 kg ; n' installez pas d'un it é s d ont le poi ds e st sup é ri eu r .
R elate d servic e informa tion 187 2. DA NGE R • Commencez tou jours par in staller les se rveurs et les b locs d ’ a limentation dans la partie inf é r i eure d e l'ar mo ir e. • Instal lez toujours les c omposants les plus lou rds dans la partie inf é rieure de l'armoire.
188 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 1. VORSI CHT • Das zul ä ssi ge H ö c h stg ew i ch t f ü r auf Schi enen m o ntie rte Ei nhe iten betr ä gt 80 k g. K eine Einhe iten mit h ö he ren Ge w i ch t einb au e n.
R elate d servic e informa tion 189 1. PERICOLO • Il peso massimo c onsentito per i dispositivi montati su slitte è d i 80 kg . Non installare dispositivi scorrevoli che hanno un peso sup eriore a quello sopra citato. • Il c entro di g ravi t à d i un 'uni t à estratta non pu ò superare i 362 mm dalla supe rficie del r ack.
190 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks 1. 2. 3. 4..
R elate d servic e informa tion 191 1. PELIG RO • El peso m á ximo permit i do para los dispositivos montados en c orr ederas es de 80 Kg (1 76 lbs ). N o instale disposit ivos deslizant es que exceda n este peso. • El centr o de gravedad de una unidad extendida no puede exceder los 362 mm (1 4,25 p gda.
192 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks • Eng lish • Brazil ian/Port ugues e • Ch inese • French • Ger man • Italian • Spanish CAUTION: The server selector unit is heavy . Y ou will need two people to safely remove th e serv er se lect or un it.
R elate d servic e informa tion 193 Ch ecklist: 1. Che ck ex teri or c ove rs f or damag e (lo ose, br oken, or sh arp edge s). 2. Power-of f the computer . Disconnect the power c or d. 3. Check the po wer cord for: a. A thi rd -wire g r ound c on nect o r i n go od co nd iti on .
194 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks — Use the round ground-pr ong of th e ac plug on ac-operat ed computers. Gr ou ndin g requi re ment s Electric al grounding of the PC Server Rack a nd computers is requir ed for operato r safety and corre ct s ys tem function.
R elate d servic e informa tion 195 Notices Refer en ces in this publication to IB M product s, pro gram s, or services do not imply that IB M intend s to mak e these av ailable in all cou ntries in w hich IB M ope rates.
196 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks Send us y our c omment s! W e want to know your opi nion abou t th is manual (part nu mber 10K2658). Y our in put will h elp u s to improve our public ations. Please photocopy this survey , complete it, and then fax it to IBM HMM S urv ey at 919-543- 8167 (USA) .
R elate d servic e informa tion 197 T rad ema rk s The following items are trademarks of the IB M Corporation in the United States or ot h er co u ntri e s or both : Apex PC Solutions, OutLook, OutLook4, and OSCAR are trademar ks of Apex PC Solut ions, I nc.
198 Hardwa re Main tenan ce Manu al: IBM PC Serv e r/Enter prise Racks.
.
IBM@ P art Numb er: 10K 2658 File Nu mber : Pr inted in the United S tates of A merica on r ecycled p aper c ontaining 10% recov ered pos t-consum er fiber.
Een belangrijk punt na aankoop van elk apparaat IBM 4SA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen IBM 4SA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens IBM 4SA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding IBM 4SA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over IBM 4SA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van IBM 4SA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de IBM 4SA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met IBM 4SA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.