Gebruiksaanwijzing /service van het product IC-F610 van de fabrikant Icom
Ga naar pagina of 36
INSTRUCTION MANUAL iF610 UHF TRUNKED RADIO IC-F610_MPT-2.qxd 05.5.10 1:00 PM Page 1 (1,1).
Icom, Icom Inc. and the logo are registered trademarks of Icom Incorporated (Japan) in the United states, the United Kingdom, Germany , France, Spain, Russia and/or other coun- tries.
i FOREWORD Thank you for purchasing this Icom product. IC-F610 UHF TRUNKED RADIO is designed and built with Icom’s superior technology and craftsmanship.
ii R W ARNING! NEVER connect the transceiver to an AC outlet. This may pose a fire hazard or result in an electric shock. NEVER connect the transceiver to a power source of more than 16 V DC such as a 24 V battery . This connection will ruin the transceiver .
iii FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . i IMPORT ANT . . . . . . . . . . . . . . . . . . . . . . . . . . . . i EXPLICIT DEFINITIONS . . . . . . . . . . . . . . . . . . i CAUTIONS . . . . . . . . . . . . . . . . . . . . . . .
1 1 P ANEL DESCRIPTION !2 !1 i r e w q !0 o u y t ■ Front panel q AF VOLUME CONTROL KNOB Rotate the knob to adjust the audio output level. • Minimum audio level is pre-programmed. w ST A TUS UP/DOWN (LEFT UP/DOWN) KEYS* [ ∫ ∫ ] / [ √ √ ] Pushing these keys will scroll up/down the status memory .
2 1 P ANEL DESCRIPTION t MEMOR Y DOWN (RIGHT DOWN) KEY* [ ] ➥ If the stored calls are displayed by pushing the Call Back key , this key scrolls down the screen. ➥ While entering the dial number via the optional microphone keypad, push the key to delete the last digit as a backspace key .
3 1 P ANEL DESCRIPTION ‘ ‘ Programmable key assignment Dealer programmable keys [P 0 ] , [P 1 ] , [P 2 ] , [P 3 ], left Up/Down [ ∫ ∫ ] / [ √ √ ] and right Up/Down [ ]/[ ] can be programmed for one of several functions by your Icom dealer .
4 1 P ANEL DESCRIPTION ■ Function display q TRANSMIT INDICA TOR Appears while transmitting. w RECEIVE INDICA TOR Appears while receiving a message. e SIGNAL STRENGTH METER Indicates the received signal strength at 4 levels. • If the connection with the communication network is not established, the whole icon turns OFF while blinks.
5 2 OPERA TION ■ T urning power ON q Push to turn the power ON. • A power-up alert tone sounds for about 1 sec. and an opening message may appear . w If the transceiver is programmed for a start up passcode, input the digit codes as directed by your dealer .
6 2 OPERA TION ‘ ‘ General Push to turn the power ON. A power-up alert tone will be heard. Push again to turn the power OFF . The following information will sequentially appear on the display . D D Opening text The pre-programmed opening text and individual ID will appear .
7 2 OPERA TION t A warning beep will be emitted 10 seconds before the communication timer reaches the limit. When the limit has been reached, the communication will be discon- nected automatically . y T o manually end the communication, push [Clear]. (or push [ ✱ ], then push [#]).
8 2 OPERA TION t A warning sound will be emitted 10 seconds before the communication timer reaches the limit. When the limit has been reached, the communication will be discon - nected automatically .
9 2 OPERA TION r Push [PTT] to send the status message to the despatch- er . t When the status message has been successfully sent out, ‘OK’ appears on the display . D D Include Call • After moving to the communication channel, you can make an additional call to the other station for them join in to the communication with you.
10 2 OPERA TION D D Group Call • Group Call to the stations having the same prefix and fleet codes. Enter the group code via the keypad and then push [#]. The group call will be started. (e.g.) T o call 200 5001 91 from 200 2001 200, enter 91#. • Group Call to the stations having the same prefix code and a different fleet code.
11 2 OPERA TION D D Emergency Call • Enter ✱ 9 ✱ plus an individual code or a group code and then push [#]. The emergency call will be started. ‘Selectable Emergency Function; Disable * ’ ➥ Enter ✱ 9, then push [#]. The pre-programmed ‘Emergency Number ’ used for the emergency call.
12 2 OPERA TION • Enter #44n ✱ plus station B’ s individual code and then push [#]. This will allow you to cancel the Divert 3rd Party call. • Enter #45n and then push [#]. This will allow you to can- cel the call that diverted to you. ➥ In the place of ‘n’, enter 1 for voice, 0 for data, or noth- ing for both voice and data.
13 3 RECEIVING ‘ ‘ Receiving a call D D Reception of an individual call When an individual call is received, the telephone beep sounds telling you that a call has been received. Immediately after this, you can talk with the caller . q The caller ’s individual code and count-down timer will appear on the LCD screen.
14 3 RECEIVING ➥ In the case of a call received from the Inter-Prefix, ‘INTER-PFIX’ is displayed on the LCD screen. ➥ The communication time timer will appear on the dis- play . w The individual ID will appear if ‘Display Pressel’ function is enabled, and remain displayed during the current communication.
15 3 RECEIVING ‘ ‘ Progress messages The following messages appear corresponding to the progress of the processing of a call. MESSAGE DESCRIPTION ABORTED . . . . . . Y our call has been aborted (W ait for a while and then make the call again). CALLING .
16 4 OTHER FUNCTION D D Call Back function • If you do not want to answer the call immediately , use this function. ➥ Pushing [Call Back] will allow you to enable or disable the function. • When this function is enabled, the transceiver sends the Call Back to the called station.
17 4 OTHER FUNCTION D D Scrambler function The transceiver is compatible with the optional UT -109 (#02)* scrambler unit. ➥ Pre-programmed 5 scrambler code can be selected in the User Setup Menu. (p. 19) NOTE: UT -109 is recommended for trunking operation.
18 4 OTHER FUNCTION D D RX Speaker function (optional OPC-617 is required) Output the receive audio to an out-of-vehicle speaker . External audio amplifier and speaker are required. D D Ignition SW function The transceiver ’s power turns ON/OFF automatically depending on the ignition switch position.
19 5 USER SETUP MENU ‘ ‘ User Setup Menu By pushing and holding down the [Clear/P 4 ] key for 2.5 sec- onds when your transceiver is in the standby mode (not dur- ing communication, dialling, or operation), the User Setup menu appears.
20 6 MAP27 ‘ ‘ MAP27 serial interface MAP27 is a Mobile Access Protocol for MPT1327/1343 com- munication equipment. It permits data exchange between MPT radio equipment and external equipment such as a data terminal which may be a laptop computer .
21 7 CONVENTIONAL MODE ‘ ‘ Conventional Mode operation This transceiver has conventional mode capability . Y ou can use up to 32 pre-programmed conventional channels. These channels can be selected with the [ ] or [ ]. ➥ Push the [Mode] key assigned as the dealer programma - ble key to toggle between T runking mode and Conventional mode.
22 7 CONVENTIONAL MODE Either Trunking or Conventional mode; [Mode] Push this key to toggle between T runking mode and Conventional mode. [Null] No function is assigned. [High/Low] Pushing this key will toggle in the order of Low1 power, Low2 power , High power and Auto power .
23 8 CONNECTION AND MAINTENANCE NEVER connect to a 24 V batter y . Solder Crimp Note: Use the terminals for the cable connections. q Antenna Optional speaker (SP-22) r t Optional cable (OPC-617 or OPC-822) e Supplied DC power cab le w 12V Battery red: blac k: ■ Rear panel and connection IC-F610_MPT-2.
24 8 CONNECTION AND MAINTENANCE q ANTENNA CONNECTOR Connects to an antenna. Ask your Dealer about antenna selection and placement. w MICROPHONE HANGER Connect the supplied microphone hanger to the vehicle ’ s ground for microphone on/off hook functions.
25 8 CONNECTION AND MAINTENANCE ■ Mounting the transceiver The front panel can be inverted for correct viewing while leav - ing the built-in speaker facing away from the mounting sur- face. D Inverting the Front panel q Unscrew the 2-side screws. w Detach the Front panel forward from the transceiver .
26 8 CONNECTION AND MAINTENANCE D Mounting the transceiver The universal mounting bracket supplied with your transceiv- er allows overhead mounting. • Mount the transceiver securely with the 4 supplied screws to a thick surface which can support more than 1.
27 8 CONNECTION AND MAINTENANCE t r e w q o i u y ■ Optional OPC-617 installation Install the OPC-617 as shown below . OPTIONAL CABLE PIN ASSIGNMENT q LCD backlight cont. IN w AF OUT for P A, RX SP . function e Det. AF OUT r Mod. IN t NC y Horn drive cont.
28 9 CLONING ‘ ‘ Cloning Cloning allows you to quickly and easily transfer the programmed contents from one transceiver to another trans- ceiver; or data from PC to a transceiver using the optional CS-F600(MPT) CLONING SOFTWARE . PC-to-transceiver cloning Please refer to the HELP file that comes with the CS-F600(MPT) CLONING SOFTWARE .
29 10 OPTIONS SP-22 EXTERNAL SPEAKER Compact and easy to install. Input impedance: 4 Ω Max. input power: 5 W HM-100TN DTMF microphone. SM-25 Desktop microphone. UT -109/UT -1 10 (#02) VOICE SCRAMBLER UNIT • UT -109: Non-rolling type (max. 32 codes) Recommended for trunking mode.
30 CE CE V ersions of the IC-F610 which display the “ CE ” symbol on the serial number seal, comply with the essential requirements of the European Radio and T elecommunication T erminal Directive 1999/5/EC.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan A-6163H-1EU- w Printed in Japan © 2002 – 2005 Icom Inc. (MPT) < Intended Country of Use > GER AUT GBR IRL FRA NED BEL LUX ESP POR ITA GRE SWE DEN FIN SUI IC-F610_MPT-2.
Een belangrijk punt na aankoop van elk apparaat Icom IC-F610 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Icom IC-F610 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Icom IC-F610 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Icom IC-F610 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Icom IC-F610 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Icom IC-F610 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Icom IC-F610 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Icom IC-F610 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.