LinCon-8000 Compact Embedded Controller Hardware User’s Manual REV 1.0.0.0 2004/9/15 LinCon8000 Series Hardw are user’s Manual, July/2003, v1.0 ----- 1.
Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning ICP DAS assumes no liability for damages consequent to the use of this product.
Table of Contents 1. INTRODUCTION ................................................................................ 4 1.1 P ACKAGE L IST & R ELEASE N OTE ...................................................................... 4 1.2 L IN C ON -8000 S ERIES .
1. Introduction 1.1 Package List & Release Note Package List : In addition to this m anual, the package includes the following items: z One set of LinCon8000 hardware z One Compact Flash Memory .
1.2 LinCon-8000 Series The LinCon-8000 is the flagship com pact embedded controller manufactured by ICPDAS. Its leading technology gives you all of the best features of both traditional PLCs and Linux capable P Cs. The LinCon-8000 syste m is powered by Linux and brings in the Linux programming style and skill into the world of PC- based PLC.
Model Description CPU Speed Embedded OS Slot Flash SDRAM Peripherals L-8031 L-8331 L-8731 Embedded Controller 206MHz Linux 0 3 7 32 Mbyte 64 Mbyte 10BaseT Ethernet Port × 1 VGA Port × 1 CF Slot × 1 USB × 1 PS/2 Keyboard × 1 PS/2 Mouse × 1 RS-232 × 1 RS-485 × 1 FRnet × 1(Option) LinCon8000 Series Hardw are user’s Manual, July/2003, v1.
1.3 Contents of CD and CF memory card CD : LinCon8000 SDK Source code of demo programs Software User’s Manual References are given in ReadMe.
2. Hardware Information The LinCon-8000 Embedded Controller is com petitive w ith Industrial PCs in performance, and is lower in price. The system provides VGA and PS/2 keyboard/mouse for local visualizat ion and management. User control programs and data can be saved in persistent storage via Compact Flash and USB interfaces.
2.2 Specifications Main Control Unit Intel Strong ARM CPU, 206MHz SRAM: 64M bytes Flash Memory: 32M bytes EEPROM: 16K bytes 64-bit hardware unique serial number Built-in Watchd.
3. Applications The following figure diagrams the genera l application area and structure of the LinCon-8000. Com2 is the standard RS232 interface, which can be connected via the modem or to the Com1 in the I-8000 C ontroller.
4. Quick S t art Step 1. Plug in your PS/2 keyboard and mouse. Step 2. Plug in your VGA monitor. Step 3. Connect the LinCon-8000 to the LAN Step 4. Insert the I-8K/87K series I/O modules into th e LinCon-8000 slots. Step 5. Connect the COM2 or the COM3 ports to your devices controlled by LinCon-8000.
5 Mechanical Information 5.1 Dimensions 5.2 Dimensions Rail Mounting 5.3 Wall Mounting LinCon8000 Series Hardw are user’s Manual, July/2003, v1.0 ----- 12.
5.4 Controller cover For safety and the controller setting memo, the LinCon-8000 provides a main controller cover to protect the reset pus h button applied under the uncontrolled situation. And it also offers an expansion slot setting record area and others configuration memo areas.
Een belangrijk punt na aankoop van elk apparaat ICP DAS USA LinCon-8000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ICP DAS USA LinCon-8000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ICP DAS USA LinCon-8000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ICP DAS USA LinCon-8000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ICP DAS USA LinCon-8000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ICP DAS USA LinCon-8000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ICP DAS USA LinCon-8000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ICP DAS USA LinCon-8000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.