range guide Commercial & Industrial Boilers & Radiators www .idealcommer cialboilers.com.
Boilers Condensing icos HE 4 W 5 plus II 6 xtra 7 Concord CXC 8 GT Condenser 9 Gas Atmospheric Concord CXA/H S/H 10 Concord Modular 11 Concord CXSi/H 12 Concord ES/H 13 High Efficiency Super Series 4 .
Ideal Boilers Ideal Boilers is one of the most respected names in the UK Commercial and Domestic heating industry . W e design and develop ranges to suit the ever changing UK marketplace. With the market’ s continued move towards condensing products, Ideal launched the condensing range.
4 condensing icos HE 30 + 36kW • W all mounted • Robust cast aluminium heat exchanger • Compact • Easy to install and service • Modulating output down to 10.4kW • Wide range of flue options • Optional remotely mountable user controls Model 30 36 Boiler Output (condensing) 50/30˚C 11.
5 • Natural gas and propane • Single unit or modular configuration, wall or frame mounted • Robust cast aluminium heat exchanger • Easy to install and service • Simple UK voltage system controls wiring • Modulating output down to 13kW • Wide range of flue options Model W45 W45P W60 W60P W80 W80P Boiler output (condensing) 13.
condensing • Range of six models • Compact size - small footprint • High modulation - Close load matching (all models down to 11.6kW) • 108.4% Net efficiency (fully condensing) at 30% part loa.
7 • Robust cast aluminium heat exchanger • In-built commissioning and fault diagnostics • Low NOx emissions • V olt free contacts supplied as standard • Meets Building Regulations 2006 (Part L2) • Compact size - small footprint • Fully modulating operation down to 20% of output • Up to 107.
8 condensing • Natural gas fired condensing boiler • Meets Building Regulations 2006 (Part L2) • Fully condensing high efficiency 85% at 80˚C, 93% at 60˚C flow • Compact space saving design • Full automatic ignition • Advanced electronic controls Model 48 70 94 116 Boiler output (condensing) 48.
9 • Up to 16% extra heat • Compact space saving design • Adjustable flue and system connections • Low flue and system resistances • High insulation levels • Fanned or standard versions •.
• Ultra reliable gas atmospheric boilers • High, full and part load efficiencies - meets Building Regulations 2006 (Part L2) • Auto ignition • Remote indication kit options • CXA/H natural g.
• Suitable for Concord CXA/H and CXS/H models • Multiple installation outputs from 80-720kW • All servicing and maintenance from the front of boilers • Large clean-out cover for full access to.
Option Kits Boiler CXSi/H V olt free contacts, alarm & boiler run conditions ✓ • Ultra reliable gas atmospheric boilers • High, full and part load efficiencies - meets Building Regulations 2.
General Data Concord ES/H (140 - 380) • High/Low adjustable operation on all models • High, full and part load efficiencies - meets Building Regulations 2006 (Part L2) • Assembled or unassembled.
• V ertical and horizontal models • High efficiency 85% (gross) • Low NOx emissions (class 5) • 50kW Modules • Sequence controlled • Compact size • Complete package gas/water headers Mod.
• Horizontal assembly • High efficiency 85% (gross) • Low NOx emissions (class 5) • 100kW Modules • Ultra compact • Sequence controlled • Easy to install and service Model 200/S 300/3 30.
• Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • Compact size • Comprehensive control • Low temperature operation Model GTE 4 GTE 5 GTE 6 Sections 4 5 6 Output.
17 • Natural gas or oil fired • High efficiency • Minimal emissions • Compact size • Comprehensive control • Low temperature operation Model GTS 4 GTS 5 GTS 6 GTS 7 GTS 8 Sections 4 5 6 7 .
18 pr essur e jet • Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • 3 pass heat exchanger • Compact size • Meets Building Regulations 2006 (Part L2) Model GTE5 .
• Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • 3 pass heat exchanger • Compact size • Meets Building Regulations 2006 (Part L2) Model GT8 GT9 GT10 GT11 GT12 .
20 pr essur e jet • Natural gas, oil fired or dual fuel • Meets Building Regulations 2006 (Part L2) • Minimal emissions • 4 pass heat exchanger • Comprehensive control • Low temperature re.
• Steel shell construction • Natural gas, oil fired or dual fuel • One or two stage operation • High efficiency 91% net (82% gross) • Reverse flame combination chamber design • Easy to ins.
22 Stelrad Radiators Stelrad Radiators Stelrad is the UK market leader in central heating radiators, offering the widest range, and in more sizes, than any other manufacturer . Our highly advanced production and distribution facility in Mexborough, UK, produces over 2.
23 • 28 Models • Heights 698 - 1800mm • Lengths 400, 500 & 600mm • Output 240 - 1022 watts • T ypes Straight/Curved - White/Chrome • Cost effective • Adds elegance Ladder & Mini .
• 216 Models • Heights 300, 450, 600, 700mm • Lengths 400 - 3000mm • Output 190 - 6033 watts • T ypes P1, K1, P+ & K2 • W orking pressure - 16psi (8 bar) • 10 Y ear W arranty Elite H.
25 Compact Height Length Output Watts at Δ T50 (mm) (mm) K1 P+ K2 P1 300 500 255 373 491 • 300 1000 509 745 982 • 300 1500 764 1118 1473 • 300 2000 1018 1490 1964 • 300 2500 1273 1863 2455 .
low surface temperatur e 26 • 72 Models • Heights 500, 650, 800mm • Lengths 560 - 1960mm • Output 196 - 2767 watts • T ypes K1, P+ & K2 • Safety grilles supplied as standard • Casing.
Disabled Adaptor The disabled adapter comes as standard and is designed to aid those who may find it difficult to manoeuver the standard control. Model Height Height Emitter Length Emitter Output Watt.
Height Length Output Watts at Δ T50 (mm) (mm) K1 K2 P+ P2 300 500 225 435 • • 300 1000 450 869 • • 300 1400 630 1217 • • 300 2000 900 1738 • • 500 400 290 514 • • 500 600 436 772 .
6 T appings The planar comes with 6 tappings enabling a multitude of installation configurations which dramatically reduce installation time. Height Length Output Watts at Δ T50 (mm) (mm) K1 K2 300 5.
30 data & dimensions Concord Height Length Elements Plane Plane (mm) (mm) Single Double Data & Dimensions - Plane 440 500 6 382 673 440 600 6 458 808 440 700 6 535 942 440 800 6 611 1077 440 9.
31 radiator options V alves Stelrad can offer a range of luxury valves to complement our design products. 3 / 4 ” Adaptor The adaptor enables you to connect to 3 / 4 ” pipework with no detriment to performance. Extension Pieces 20/30 and 40mm extension pieces are available to help bridge gaps on replacement installations.
20 40 100 150 200 600 800 1000 1500 3500 68 136 340 511 682 2047 2729 3412 5118 11942 Boiler output Concord CXS/H Concord CXSi/H Concord ES/H Concord Modular Concord Super Series 4 Buccaneer GTE Falco.
Een belangrijk punt na aankoop van elk apparaat IDEAL INDUSTRIES 30 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen IDEAL INDUSTRIES 30 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens IDEAL INDUSTRIES 30 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding IDEAL INDUSTRIES 30 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over IDEAL INDUSTRIES 30 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van IDEAL INDUSTRIES 30 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de IDEAL INDUSTRIES 30 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met IDEAL INDUSTRIES 30 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.