Gebruiksaanwijzing /service van het product iMcV-T1/E1/J1 van de fabrikant IMC Networks
Ga naar pagina of 21
iMcV-T1/E1/J1 Operation Manual.
FCC Radio Frequency Interference Statement This equipment has been tested and found to comp ly with the limi ts for a Class B computi ng device, pursuant to Part 15 of the F CC Rules. These limits are designed to provide reasona ble protection agains t har mful interferenc e when the equi pment is operated in a com merc ial environment.
Table of Content s FCC Radio Frequency Interference Stateme nt .................................................... ii Warranty ............................................................................................................ ii About th e iMcV-T1/E 1/J1 .
About the iMcV-T1/E 1/J1 The i McV-T1/ E1/J1™ chass is mou nted medi a conversion module allows you to extend the distances between T1, J1, and E1 co pper telephony systems by addi ng a fiber segmen t. The d istances you can add ran ge from 2 km to 100km dependin g on the module used an d the fiber t ype available.
Configuration The iMcV-T1/E 1/J1 module is factory-configur ed to use the fo llowing defa ult features : • T1/ E1 Mo de .................................................................................................... T1 • Receive Equalizer Gain Limit ( EGL) : .
Available configurations enable d by DIP switches (and iView 2 ): T1 Mode Configurations (default) • Receive Equalizer Gain Limit (EGL) iView 2 o -36 dB (Long Haul) o -30 dB (Limited Long Haul) (def.
Installation At the central location the iMc V-T1/E1/J1 unit is typically install ed in a managed chassis su ch as the iMediaChassis or the iMediaCenter .
MediaChassis The MediaCha ssis provides a ty pical unmanaged chassis suitable for all r emote installation locations. NOTE Chassi s may also be available in Industria l Ethernet (I E) configur ations.
DIP Switch Tabl e T1/E1 Se lection S2-1: OFF T1 Mode Selected default S2-1: ON E1 Mode Selected Receive Equalizer Gain Limit (EGL) E1 iVIEW 2 S2-2: ON -12 dB (Short Haul) iVIEW 2 S2-2: OFF -43 dB (Lon.
10.
Unmanaged Modules Before installing the i McV-T1/E1/J1 modul e into an unmanaged chassis, configure the module hard ware-sel ectable featur es via DIP switches loca ted at positi on S3 and S2 on the PCB (refer to t he DIP Switch Table section for more infor mation).
Receive LIU Termination (Line Termination) This opt ion allows you to se t the rece ive term ination. T his is used to properly terminate c ables in order t o prevent signal r eflections w hich can cause sign al degradation.
Remote Ma nage ment This option allo ws you to enable R emote management on the modul e. The re mote manageme nt fea ture i s desig ned to work only on th e remote modu le of the Local/Remote pair . With Remote management enabled, you can e asily perform the following: • Test t he line integ rity of the remote copper port.
Module LED Functions This sec tion desc ribes th e LEDs and their f u nctions. The Fiber port LED RM is the only LED t hat should b e lit on th e modules under normal operating c onditions. Copper Port LEDs LPBK Glows gr een when the mo dule is set t o one of the Loopback mode s.
Testing To test a media converter by itself, first make sure y ou have an appropriate fi ber patch cable, then perform the following ste ps: 1. Connect t he media c onverter t o the T1/E1 device wit h a standar d UTP cable. I f the NO LNK LED for the copper port remains on, you are n ot receiving a valid signal.
The iMcV-T1/E 1/J1 can be configured to use the foll owing loopback test modes: • Local Fiber Loopbac k Mode This set ting te sts the path from the CO coppe r port to the Local iMcV -T1/E1/ J1 module fiber port an d back.
Remote Fiber Loopback Mode To se t the loopback testing m ode to Remote Fiber Loo pback Mode , perfo rm the following: 1. Set the Local iMcV-T1/E1/J 1 module Loopback to None (DIP switch S3-3=On and S3-4=On) 2. Set the Remote iMcV -T1/ E1/J1 mod ule to Local Loopback (DIP switch S3-3= Off and S3-4= On).
Testing with Pseudorandom Bit Sequence (PRBS) To test the copper segment from the Remote module to the Customer Prem ises Equipment (CPE) by us ing PRBS, perfor m the following: 1. Set the CPE to l oopback the signal. 2. Set the Remote module to genera te PRBSs (DIP switch S2-9=On an d S2-10=Off).
Specifications Power Cons umption (Typi cal): 0.550 Amp Operatin g Temperatur e: 32° to 122° F ( 0° to 50° C) Storage Te mperature : 0° to 160°F (-20° t o 70° C) Humidity: 5 to 95% (non-co ndensing); 0 to 10,000 ft.
Saf ety C ertif icat ion s UL/CUL: Listed to Safety of Informati on Technology Equip ment, including Electrical Busin ess Equipm ent. CE: The p roducts de scribed herein comply wi th the C ouncil Dire.
19772 Pauling • Foothill Ranch, CA 926 10-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetwork s.com © 2007 IMC Networks. Al l rights reserved The informatio n in this documen t is subje ct to ch ange with out noti ce. IMC Networks assumes no respo nsibility f or any errors t hat may appear i n this document.
Een belangrijk punt na aankoop van elk apparaat IMC Networks iMcV-T1/E1/J1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen IMC Networks iMcV-T1/E1/J1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens IMC Networks iMcV-T1/E1/J1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding IMC Networks iMcV-T1/E1/J1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over IMC Networks iMcV-T1/E1/J1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van IMC Networks iMcV-T1/E1/J1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de IMC Networks iMcV-T1/E1/J1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met IMC Networks iMcV-T1/E1/J1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.