Intel ® Entry Server Board SE7221BA1-E User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C92730-002.
Disclaimer Disclaimer Information in this document is provided in connection with Intel ® products. No license, expres s or implied, by estoppel or otherwise, to any intellectual property rights i s granted by this document.
Preface Preface About this Manual Thank you for purchasing and using the In tel® Entry Server Board SE7221BA1-E. This manual is written for system technicians w ho are responsible for tr oubleshooting, upgrading, and repairing this server board.
Server Board Features Additional Information and Software If you need more information about this product or inf ormation about the accessories that can be used with this server board, use the followi ng resources. These files are available at: http://support.
Preface Safety Informa tion WARNING Before working with your server product, whet her you are using this guide or any other resource as a reference, pay close attention to th e safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals.
Server Board Features Safety Cautions Read all caution and safety statements in this document before performing a ny of the instructions. t See also Intel® Server Boards and Ser ver Chassis Safety Information on the Resource CD and/or a http://support.
Preface 重要安全指导 在执行任何指令之前,请 阅读本文档中的所有注 意事项及安全声明。参见 Resource CD(资源光盘) 和/或 http://support.
Server Board Features electrostática (ESD). Puede hacerlo si utiliza una muñequera anti estática sujetada a la toma de tierra del chasis — o a cualquie r tipo de superficie de metal sin pintar. 6. No ponga en marcha el siste ma si se han extraído las tapas del chasis.
Contents Contents 1 Server Board Features ................................................................................... 1 Connector and Component Locations ..................................................................................... 3 Back Panel Connectors .
Server Board Features Problems with Network ................................................................................................. 30 System Boots when Installing PCI Card ....................................................................
Contents Figures Figure 1. Intel® Entry Server Board SE7221BA1-E ..................................................................... 1 Figure 2. Server Board Connector and Component Locations .................................................... 3 Figure 3.
Server Board Features 1 Server Board Features This chapter briefly describes the main features of the Intel® Entry Server Board SE7221BA1-E. Provided is a photograph of the product, a list of the server board features, and diagrams showing the location of important components an d connections on the server board.
Server Board Features Feature Description Four Serial ATA channels, via the ICH6-R, one dev ice per channel One IDE interface with ATA-66/100 support One diskette drive interface One p.
Server Board Features Connector and Component Locations TP01370 J B E H A F C D G I II HH JJ KK LL GG EE X W Y V U Z AA BB L K CC DD FF M N O S Q T R P A: Conventional PCI Slot 3 K: 2 x 4 Power Connec.
Server Board Features Back Panel Connectors TP01371 C D B F A E A Keyboard / Mouse D Video B Serial P ort A E Intel® 82551QM (10/100) / USB 0, 1 C Parallel Port F Marvell* 88E8050 (Gigabit) / USB 2, 3 Figure 3. Back Panel Connectors The NIC LEDs at the right and left of each NIC provide the following information: Table 2.
Server Board Features Hardware Requirements To avoid integration difficulties and possible board damage, your system must meet the requirements outlined below. For a list of qualified components, see the links under “ Additional Information and Software .
Server Board Features NOTE System resources (such as PCI and PC I Express*) require physical memory address locations that reduce available memory addresses above 3 GB. This may result in less than 4 GB of memory being available to the operating system and applications.
Hardware Installa tions and Upgrades 2 Har d ware Installations and Upgrades Before You Begin Cautions and Warnings indicate conditions th at, if not observed, can cause personal injury.
Hardware Installa tions and Upgrades Tools and Supplies Needed Phillips (cross head) screwdriver (#1 bit and #2 bit) Needle nosed pliers A ruler Pen or pencil Antistatic wrist stra.
Hardware Installa tions and Upgrades If additional memory is to be used, install anot her matched pair of DIMMs in DIMM 1 (black) in both channels A and B (see Figure 5). Channel A 256 MB, 400 MHz DIMM 0 512 MB, 400 MHz DIMM 1 Channel B 256 MB, 400 MHz DIMM 0 512 MB, 400 MHz DIMM 1 Figure 5.
Hardware Installa tions and Upgrades 4. Remove the PCI Express* card if it interfere s with the DIMM retaining clips from being easily opened and closed. TP01373 Channel A, DIMM 0 Channel A, DIMM 1 Channel B, DIMM 0 Channel B, DIMM 1 A C D B Figure 7.
Hardware Installa tions and Upgrades 6. Gently spread the retaining clips at each end of the DIMM socket. The DIMM pops out of the socket. 7. Hold the DIMM by the edges, lift it away from the socket, and store it in an anti-static package. 8. Reinstall and reconnect any parts you remove d or disc onnected to reach the DIMM sockets.
Hardware Installa tions and Upgrades 3. Lift the load plate. Do not touch the socket contacts . Figure 9. Lift the Load Plate 4. Remove the protective socket cover from the load plate. Do not discard the protective socket cover. Always replace the socket cover if the processor is removed from the socket.
Hardware Installa tions and Upgrades TP01377 Figure 11. Remove the Processor from the Protective Processor Cover 6. Hold the processor with your thumb and index fi ngers oriented as shown in Figure 12. Make sure fingers align to the socket cutouts. Ali gn notches with the socket.
Hardware Installa tions and Upgrades processor fan heat sink RM, refer to the boxed processor manual or the Intel World Wide W eb site at: http://support.Intel.com/support/processors/pentium4/intnotes478.htm Connecting the Processor Fan Heat Sink Cable Connect the processor fan heat sink cable to the 4-pin processor fan header.
Hardware Installa tions and Upgrades 4. Secure the card’s metal bracket to the chassis back panel with a screw. Removing the PCI Express* x8 Card Follow these instructions to remove the PCI Express* x8 card from the RM: 1. Observe the precautions in " Safety Information " at the beginning of this document.
Hardware Installa tions and Upgrades TP01382 Figure 15. Replacing the Backup Battery CAUTION Risk of explosion if the battery is repl aced with an incorrect type. Batteries should be recycled where possible. Disposal of used batteries must be in accordance with local environmental regulations.
Hardware Installa tions and Upgrades VARO Räjähdysvaara, jos pariston tyyppi on vä ärä. Paristot on kierrätettävä, jos se on mahdollista. Käytetyt paristot on hävitettävä paikallisten ympäristömääräysten mukaisesti. VORSICHT Bei falschem Einsetzen einer neuen Ba tterie besteht Explosionsgefahr.
Hardware Installa tions and Upgrades Προσοχή Υπάρχει κίνδυνος για έκρηξη σε περίπτωση που η µ παταρία αντικατασταθεί από µ ία λανθασ µ ένου τύπου .
Hardware Installa tions and Upgrades POZOR Zamenjava baterije z baterijo druga č nega tipa lahko povzro č i eksplozijo. Č e je mogo č e, baterije reciklirajte.
Hardware Installa tions and Upgrades A TTENZJONI UPOZORNENIE 20 Intel® Entry Server Board SE7221BA1-E User Guide.
Server Utilities 3 Server Utilities Using the BIOS Setup Utility The BIOS Setup program is accessed by pressing the <F2> key after the Power-On Self-Test (POST) memory test begins and before the operati ng system boot begins. For the latest BIOS Setup menu options, go to the Intel World Wid e Web site: http://support.
Server Utilities 5. Place the jumper on pins 2-3 as shown below. 3 1 6. Replace the cover, plug in the computer, turn on the computer, and allow it to boot. 7. The computer starts the Setup program. Setup displays the Maintenance menu. 8. Use the arrow keys to select Clear Passwords.
Server Utilities The Iflash Memory Update utility allows you to: Update the BIOS in flash memory Update the language section of the BIOS Updating the BIOS CAUTION The AUTOEXEC.BAT file provided with the update files updates the BIOS. Do not interrupt the process or the system may not function.
Server Utilities successful recovery of the boot block. This sequence of events indicates a successful BIOS recovery. • A series of continuous beeps indicates a failed BIOS recovery. 7. If recovery fails, return to step 1 and repeat the recovery process.
Troubleshooting 4 T r oub leshooting This chapter helps you identify and solve probl ems that might occur while you are using the system. For any issue, first ensure you are using the latest firmware and files. Firmware upgrades include updates for BIOS, the baseboard management c ontroller (BMC), and the hot-swap controller (HSC).
Troubleshooting Are all peripheral devices installed correctly? If the system has a hard disk drive, is it properly formatted or configured? Are all device drivers properly installed? Are the configuration settings made in Setup correct? Is the operating system properly loaded? Re fer to the operating system documentation.
Troubleshooting Confirming Loading of the Operating System Once the system boots up, the operating system prompt appears on the screen. The prompt varies according to the operating system. If the opera ting system prompt does not appear, see “ No Characters Appear on Screen .
Troubleshooting No Characters Appear on Screen Check the following: Is the keyboard functioning? Test it by turnin g the “Num Lock” function on and off to make sure the Num Lock light is functioning.
Troubleshooting System Cooling Fans Do Not Rot ate Properly If the system cooling fans are not operating prope rly, it is an indication of possible system component failure.
Troubleshooting Cannot Connect to a Server Make sure the network cable is securely attached to the correct co nnector at the system back panel. Try a different network cable. Make sure you are using the correct and the current drivers. See “ Additional Information and Software ” for a link to the current drivers.
Troubleshooting Turn off the server power by using the power button on the front of the system. Unplug the AC power cord(s) from the server. Problems with Newly Insta lled Application Software Problems that occur when you run new application so ftware are usually related to the software, not the server hardware.
Troubleshooting Devices are not Recognized under Device Manager The Windows* operating systems do not include all of the drivers fo r the Intel chipsets, onboard NICs, and other components. See “ Additional Information and Software ” for a link to the current drivers and chipset files.
Troubleshooting BIOS POST Beep Codes The Server Board SE7221BA1-E reports POST errors in two ways: By sounding a beep code By displaying an error message on the monitor BIOS Beep Codes The BIOS beep codes are listed in Table 5.
Troubleshooting Error Message Explanation DMA Error Error during read/write test of DMA controller. FDC Failure Error occurred trying to access diskette drive controller. HDC Failure Error occurred trying to access hard disk cont roller. Checking NVRAM.
Regulatory and Certification Information Regulator y and Cer tification Inf ormation WARNING To ensure regulatory compliance, you must adh ere to the assembly ins tructions in this guid e to ensure and maintain co mpliance with existing product certificat ions and approvals.
Regulatory and Certification Information EN55022 - Emissions (Europe) EN55024 - Immunity (Europe) CE – EMC Directive 89/336/EEC (Europe) VCCI Emissions (Japan) AS/NZS 3548 Emissions (Australia / New.
Regulatory and Certification Information Product Regulatory Compliance Markings The Intel Server Baseboard bears the following regulatory marks. Regulatory Compliance Country Marking UL Mark USA/Canad.
Regulatory and Certification Information Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules.
Regulatory and Certification Information Europe (CE Declaration of Conformity) This product has been tested in accordance too, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). Th e product has been marked with the CE Mark to illustrate its compliance.
Regulatory and Certification Information 5. Manufacturer/Nation: Intel Corporation/Re fer to country of origin marked on pr oduct CNCA (CCC-China) The CCC Certification Marking and EMC warning is located on the outside rear area of the product.
Getting Help Getting Help World Wide Web http://support.Intel.com/support/mot herboards/server/SE7221BA1-E/ Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card e x c h a n g e r a t e p l u s a p p l i c a b l e t a x e s .
Getting Help In Latin America Brazil 001-916 377 0180 Mexico Contact AT&T USA at 001 800 462 628 4240. Once connecte d, dial 800 843 4481 Colombia Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481 Costa Rica Contact AT&T USA at 0 800 0 114 114.
Intel® Server Issue Report Form Intel® Server Issue Repor t Form Date Submitted: Company Name: Contact Name: Email Address: Intel® Server Product: Priority (Critical, Hot, High, Low): Brief Problem Description. Provide a brief description below. See the last page for space to include a detailed problem description.
Intel® Server Issue Report Form Operating System Information Operating System _________________________________ ___________________________ Version ___________________________________________________.
Intel® Server Issue Report Form Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done.
Een belangrijk punt na aankoop van elk apparaat Intel SE7221BA1-E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Intel SE7221BA1-E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Intel SE7221BA1-E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Intel SE7221BA1-E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Intel SE7221BA1-E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Intel SE7221BA1-E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Intel SE7221BA1-E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Intel SE7221BA1-E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.