Gebruiksaanwijzing /service van het product BAR750 van de fabrikant Invacare
Ga naar pagina of 32
Owner’s Operator and Maintenance Manual DEALER: This manual MUST be given to the user of the bed. USER: BEFORE using this bed, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.
BAR750 2 Part No 1143215 WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANU AL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS, AND INSTRUCTIONS, CONTA.
TABLE OF CONTENTS Part No 1143215 3 BAR750 TABLE OF CONTENTS SPECIAL NOTES ................................................................................ 7 TYPICAL PRODUCT PARAMETERS .................................................... 8 LABEL LOCATIONS .
TABLE OF CONTENTS BAR750 4 Part No 1143215 TABLE OF CONTENTS SECTION 4—PACKAGING, HAND LING AND SET-UP ......................... 22 Receiving ............. .......................................................................................... ..
Name _______________________________________________________________ Address _____________________________________________________________ City ___________________ State/Province __________ Zip/Postal Code ________ Email ___________________________________ Phone No.
Fold here Fold here Cut Along Line Invacare Product Registration Form Please Seal with Tape Before Mailing.
SPECIAL NOTES Part No 1143215 7 BAR750 SPECIAL NOTES Signal words are use d in this manual and apply to hazards or unsafe practices which could result in personal injury or propert y damage.
TYPICAL PRODUCT PARAMETERS BAR750 8 Part No 1143215 TYPICAL PRODUCT PARAMETERS BAR 750 BARIATRIC BED MAXIMUM OVERALL WIDTH: 48 inches (121.9 cm) WIDTH EXTENDER: 39 inches (99 cm) 42 inches (106.6 cm) 48 inches (121.9 cm) MAXIMUM OVERALL LENGTH (WITH HEADBOARD AND FOOTBOARD): 88 in che s (22 3.
LABEL LOCATIONS Part No 1143215 9 BAR750 LABEL LOCATIONS NOTE: The same labels are located on the othe r side of the bed.
SECTION 1—GENERAL GUIDELINES BAR750 10 Part No 1143215 SECTION 1—GENERAL GUIDELINES WARNING SECTION 1 - GENERAL GUIDELIN ES contai ns important inform ation for the safe operation and use of this product.
SECTION 1—GENERAL GUIDELINES Part No 1143215 11 BAR750 Operating Information Check all parts for shipping damage and test before using. In case of damage, DO NOT use. Contact a qualified technician for further instruction.
SECTION 1—GENERAL GUIDELINES BAR750 12 Part No 1143215 ENTRAPMENT WARNING Proper patient assessment and monitoring, and proper maintenance and use of equipment is required to reduce the risk of entrap ment. Variations in bed rail dimensions, and mattress th ickness, size or density could increase the risk of entrapment.
SECTION 1—GENERAL GUIDELINES Part No 1143215 13 BAR750 DO NOT use the bed rails as push handles for moving the electric bed.
SECTION 1—GENERAL GUIDELINES BAR750 14 Part No 1143215 Grounding Instructions Electric beds are equipped with three ‐ prong (grounding) plugs for protection against possible shock hazards.
SECTION 2—OPERATION Part No 1143215 15 BAR750 SECTION 2—OPERATION Operating Bariatric Bed WARNING NEVER operate if the unit has a damaged cord or plug. If it is not working properly, call a qualified technician for examination and repair. Keep all electrical cords away from heated or hot surfaces.
SECTION 2—OPERATION BAR750 16 Part No 1143215 Raising and Lowering the Head and Foot Sections NOTE: For this proced ure, re fe r to FIGURE 2.2. 1. T o raise the head of the bed, press the Head UP button.
SECTION 2—OPERATION Part No 1143215 17 BAR750 3. Move the bed in a straight line about three feet backw ard or forward to lock. NOTE: This action will keep the caster fro m swiveling and allow better forwar d and backward movement.
SECTION 2—OPERATION BAR750 18 Part No 1143215 FIGURE 2.4 Adjusting Bed Rail Release Knob Bed Rail.
SECTION 3—MAINTENANCE Part No 1143215 19 BAR750 SECTION 3—MAINTENANCE CAUTION To protect flooring, en sure bed end is completely draine d and dry before placing on flooring. Otherwise, rema ining dirty water may da mage or stain flooring. Avoid spraying water directly into the gear bo x ends.
SECTION 3—MAINTENANCE BAR750 20 Part No 1143215 ❑ Check all function s: A. Head section raises and low ers properly . B. Foot section raises and lowers properly . C. Bed raises and lowers properly .
ASSEMBLY, MAINTENANCE AND ADJUSTME NT SECTIONS - FOR DEALERS ONLY Part No 1143215 21 BAR750 ASSEMBLY, MAINTENANCE AND ADJUSTMENT SECTIONS - FOR DEALERS ONLY WARNING The procedures in the follo wing sections MUST be performed by a qualified technician.
SECTION 4—PACKAGING, HANDLING AND SET-UP BAR750 22 Part No 1143215 SECTION 4—PACKAGING, HANDLING AND SET-UP Receiving 1. Count cartons before signing shipping papers. 2. Designate someone at the facility to receive and inspect all merchandise.
SECTION 4—PACKAGING, HANDLING AND SET-UP Part No 1143215 23 BAR750 8. Pull the head ‐ end section from the shipping bracket. 9. Remove the cl evis pin securing the shipping bracket to foot ‐ end section from each side of the foot ‐ end section.
SECTION 4—PACKAGING, HANDLING AND SET-UP BAR750 24 Part No 1143215 FIGURE 4.1 Assembling the Bed DETAIL “A” DETAIL “B” DETAIL “C” DETAIL “D” DETAIL “E” DETAIL “F” DETAIL “G.
SECTION 4—PACKAGING, HANDLING AND SET-UP Part No 1143215 25 BAR750 Adjusting the Bed Adjusting Length NOTE: For this proced ure, re fe r to FIGURE 4.2. 1. Pull down on the release knob located under the head section of the bed.
SECTION 4—PACKAGING, HANDLING AND SET-UP BAR750 26 Part No 1143215 Inspecting the Bed Examine each item carefully for scratches, nicks, dents or any other apparent damage. NOTE: Check all parts for shipping damage.
SECTION 5—MAINTENANCE Part No 1143215 27 BAR750 SECTION 5—MAINTENANCE Maintenance Checklist Inv acare recommends the following maintenance procedures be conducted at least once every three years.
SECTION 6—TROUBLESHOOTING BAR750 28 Part No 1143215 SECTION 6—TROUBLESHOOTING WARNING Read all general guidelines, warnings a nd cautions before performing any repair/maintenance on the bed. All repair and main tenance on the bed should be performed by a qualified te chnician.
SECTION 6—TROUBLESHOOTING Part No 1143215 29 BAR750 Troubleshooting: Mechanical SYMPTOM PROBABLE CAUSE SOLUTIONS Bed does not stay in place. Locking casters not locked. Lock casters. Refer to Locking the Casters on page 16. Pressing function on pendant results in motion other than that intended.
SECTION 6—TROUBLESHOOTING BAR750 30 Part No 1143215 NOTES.
LIMITED WARRANTY Part No 1143215 31 BAR750 LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABL E TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the ori ginal purchaser who purchases this product when new and unused from Invacare or a dealer.
Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800-668-5324 Invacare, the Medallion Design, and Yes, you can. are register ed trademarks of Invacare Corporation.
Een belangrijk punt na aankoop van elk apparaat Invacare BAR750 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Invacare BAR750 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Invacare BAR750 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Invacare BAR750 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Invacare BAR750 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Invacare BAR750 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Invacare BAR750 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Invacare BAR750 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.