Invacare ® Therapeutic Support Surfaces Catalog 06-059 9/26/06 7:58 AM Page 1.
Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 2 Patients immobilized and unable to move can suffer serious destruction of the skin and soft body tissue in as little as one hour . This often results in the formation of a pressure ulcer .
Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 3 Stages of Pressure Ulcers Pressure ulcers can be graded from Stage I to Stage IV to classify the degree of tissue damage. Pressure ulcers do not necessarily progress from Stage I to Stage IV or heal from Stage IV to Stage I.
Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 4 • Always follow the directions and advice given by the prescribing physician. • Elevate the head of the bed no more than 30˚ whenever possible for maximum pressure distribution.
Invacare ® Therapeutic Support Surfaces GROUP I Invacare ® Therapeutic Support Surfaces 5 Invacare ® CareGuard ™ 101 Foam Mattress Model no. CG101080, CG10180CA Invacare ® Gel Foam Mattress Overlay Model no. IVCGFMO Invacare ® CareGuard ™ APP Alternating Pressure Pad System Model no.
Invacare ® Therapeutic Support Surfaces Group II Invacare ® Therapeutic Support Surfaces 6 Invacare ® Alternating Pressure Mattress System Model no. MNS400-E Invacare ® Alternating Pressure Mattress System Model no. MNS400-S, MNS400-B Invacare ® Low Air Loss Mattress Replacement System Model no.
Group II Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 7 Invacare ® microAIR ® 3500S ™ Low Air Loss System Model no. BB9572000 Invacare ® Low Air Loss with Alternating Pressure Mattress Replacement System Model no.
Invacare ® Therapeutic Support Surfaces Group II Invacare ® Therapeutic Support Surfaces 8 Invacare ® microAIR ® T urn-Q ® Plus Low Air Loss with Rotation System Model no.
Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 9 Medicare Coverage Criteria* In order to qualify for a therapeutic support surface, patients must meet certain criteria. A Group I support surface is covered if the patient meets either of the following scenarios: 1.
Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 10 Gel Overlay Foam Mattress Alternating Pressure Non-powered Alternating Pressure Model Name CareGuard ™ Gel Foam M.
Invacare ® Therapeutic Support Surfaces Invacare ® Therapeutic Support Surfaces 11 Low Air Loss Lateral Rotation MNS400-S / MNS400-B MNS500AP / MSN500AP-B BB9572000 MNS500-S / MSN500-B BB9612000 MNS600-S / MNS600-B EO277 EO277 EO277 EO277 EO277 EO277 $645.
Invacare Corporation www .invacare.com USA One Invacare W ay Elyria, Ohio 44035-4190 (800) 333 - 6900 Canada 570 Matheson Blvd. E. Unit 8 Mississauga, Ontario L4Z 4G4 Canada (800) 668 - 5324 Invacare, the Blue Medallion Design, Y es, you can.
Een belangrijk punt na aankoop van elk apparaat Invacare IVCGFMO (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Invacare IVCGFMO heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Invacare IVCGFMO vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Invacare IVCGFMO leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Invacare IVCGFMO krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Invacare IVCGFMO bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Invacare IVCGFMO kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Invacare IVCGFMO . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.