Gebruiksaanwijzing /service van het product EVOi.net van de fabrikant JBL
Ga naar pagina of 36
User’ s Guide Introducing The Next Generation of Installed Sound A Loudspeak er W ith Intelligence.
CONTENTS Safety Information . . . . . . . . . . . . . . . . . . . . . 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Design Overview . . . . . . . . . . . . . . . . . . . . . . 3 Features EVOi.net Front . . . . . . . . . . . . . .
EVOi.net 1 IMPORT ANT SAFETY INFORMA TION - READ THIS CAREFULL Y This equipment has been tested and found to comply with the following European and international standards for Electromag- netic Compat.
EVOi.net 2 INTRODUCTION WELCOME P ACKAGE CONTENTS Upon unpacking the EVOi.net please take note of the contents as listed below . If you do not have the contents listed then please contact your dealer as soon as possible.
EVOi.net 3 DESIGN OVER VIEW The EVOi.net is either supplied in a 19” rack mount configuration or as part of the EVOi.sys. Simplicity in the presentation is at the forefront of the EVOi.net design. For installed loudspeaker systems, it is not practical to initiate setup and operational function with control on the actual loudspeakers.
EVOi.net 4 FEA TURES FRONT P ANEL 5 1 7 9 8 4 2 3 6 1 INPUT Indicators T wo sets of LED indicators monitor audio signal levels at the inputs A (left) and B (right).
EVOi.net 5 FEA TURES 6 A UT O EQ SETTING AUTO EQ SETTING includes two setup buttons, MAIN SETUP 1&2 and AUX SETUP 3&4 , and associated LED indicators for state confirmation. For detailed operation, refer to See Using The Auto EQ Setting on page 1 1.
EVOi.net 6 10 RU Mounting Holes The EVOi.net is equipped with four mounting holes for installation in one RU (rack unit) space. 11 Po wer Connector Insert the enclosed power cord into the IEC connector to supply the specified AC power . 12 Fuse The removable fuse protects internal circuits.
EVOi.net 7 INST ALLA TIONS/SETUP ST ARTING UP Installation Notes Although installing an EVOi.net is straightforward, please review the following notes to achieve the best installation: • Choose a mounting location that provides direct front panel viewing and easy access to the controls.
EVOi.net 8 INST ALLA TIONS/SETUP ST ARTING UP Connecting Measur ement Microphone IMPOR T ANT : EVOi.net is supplied with a dedicated JBL Measurement Microphone and 100’ XLR - XLR balanced signal cable. Successful setup will ONL Y occur if the JBL Measurement Microphone is used.
EVOi.net 9 INST ALLA TIONS/SETUP ST ARTING UP Initial Settings and Powering Up Upon activation, all of the LEDs on the front panel should light up once and then go out.
EVOi.net 10 INST ALLA TIONS/SETUP ST ARTING UP (continued) T esting the System At the beginning of or anytime during a system setup, the hookup configuration of the EVO loudspeaker can be tested by using the TEST button. This button is used to control the user audio test mode, i.
EVOi.net 11 INST ALLA TIONS/SETUP USING THE AUTO EQ SETTING 1X 2X 3X Placing Measurement Micr ophone for MAIN EV O Loudspeakers For simple applications of up to two EVO loudspeakers hooked up to OUTPUTS 1A and 2B (the MAIN OUT outputs), optimum placement of the Measurement Micro- phone is illustrated in Figure 10.
EVOi.net 12 INST ALLA TIONS/SETUP SETTINGS AUTO EQ SETTING LOCKED EQ SET TEST AEQ ON MAIN OUT SETUP 1&2 EQ SET AUX OUT SETUP 3&4 HOLD TO CLEAR MAIN HOLD TO CLEAR MAIN Perf or ming Auto EQ for MAIN OUT Loudspeak er s Before starting, check that the LOCKED indicator is off.
EVOi.net 13 LINK OUT LINK IN 4 B 3 A 2 B 1 A INTERFACE FLOATING BALANCED OUTPUTS MONO SUM MONO SUM Figure 15 - AUX Out Speakers 3A and 4B INST ALLA TIONS/SETUP SETTINGS AUTO EQ SETTING LOCKED EQ SET T.
EVOi.net 14 INST ALLA TIONS/SETUP DELA Y SETTING EVO Loudspeakers hooked up to AUX OUT 3A & 4B outputs can be instructed to automatically set their correct delay and level to perform optimally with EVO Loudspeak- ers hooked up to MAIN OUT 1A & 2B outputs.
EVOi.net 15 LIVE OPERA TION ANTI FEEDBACK CONTROL EQ SELECT SETTINGS FIXED AFC SET FILTERS FREE 1 2 3 LIVE AFC ON MUSIC I MUSIC II SPEECH NEUTRAL LOCKED TEST FIXED SETUP HOLD TO CLEAR FIXED HOLD TO CLEAR LIVE ANTI FEEDBACK CONTROL T wo different types of Anti Feedback Control engines can be initiated and set up via EVOi.
EVOi.net 16 LIVE OPERA TION Live Anti Feedbac k Contr ol Initiate Live Anti Feedback Control by pressing the square button. LIVE AFC ON will illuminate.
EVOi.net 17 EVOi.net Rear (NOTE: For clarity , power connections are not shown.) Speaker Placement In Room XLR Si gnal Cable EVOi.324 Input EVOi.324 Main Audio Output (from Mixer) IMPORT ANT : Make sure POWER is off before making connections. Mono Mono Mono In Main Mono XLR Si gnal Cable Approximate measurement microphone placement.
EVOi.net 18 APPLICA TIONS EVOi.net IN RECT ANGULAR ROOMS (continued) Longer Rectangular Room: EVOi.net + 1 Main (Mono) EVOi.324 + 1 Delay (Mono) EVOi.324 In a longer rectangular room, additional coverage may be required. Page 12 of the EV Oi.324 Users Guide illustrates a typical application.
EVOi.net 19 APPLICA TIONS EVOi.net IN RECT ANGULAR ROOMS Smaller/Wider Rectangular Room: EVOi.net + 2 Main (Stereo) EVOi.324s The hook up diagram below illustrates the most typical EVO Systems configuration.
EVOi.net 20 APPLICA TIONS EVOi.net IN RECT ANGULAR ROOMS (continued) Longer / Wider Rectangular Room: EVOi.net + 2 Main (Stereo) EVOi.324s + 2 Delay (Stereo) EVOi.324s In large rooms, an EVO system as illustrated in the inset diagram may be required. EVOi.
EVOi.net 21 APPLICA TIONS EVOi.net IN RECT ANGULAR ROOMS Longer / Wider Rectangular Room: EVOi.net + 2 Main (Mono Array) EVOi.324s + 2 Delay (Mono Array) EVOi.324s Another typical configuration for larger rooms is to configure two mono arrays, as illustrated in the inset diagram.
EVOi.net 22 APPLICA TIONS EVOi.net IN F AN-SHAPED ROOMS Small Fan-Shaped Room: EVOi.net + 1 Main (Mono) EVOi.324 EVOi.net hook up configuration and Measurement Microphone are as illustrated below . The setup is identical to EVOi.net in a Small Rectangular Room.
EVOi.net 23 APPLICA TIONS EVOi.net IN F AN-SHAPED ROOMS Medium Fan-Shaped Room: EVOi.net + 2 Main (Mono Array) EVOi.324s For a medium size Fan Shaped Room, broader coverage may be required, therefore the EVOi.324s are configured as illustrated below (see EVOi.
EVOi.net 24 APPLICA TIONS EVOi.net IN F AN-SHAPED ROOMS (continued) Large Fan-Shaped Room: EVOi.net + 2 Main (Mono Array) EVOi.324s + 2 Delay (Mono) EVOi.324s For a Large Fan Shaped Room, the Main Array is set up and hooked up to EVOi.net as illustrated below .
EVOi.net 25 APPENDIX POWER UP OPERA TION There are two scenarios: a) EV O Speakers have been changed/replaced or the speakers hook up configuration is different.
EVOi.net 26 TROUBLESHOOTING EVOi.net is used as the interface for the set up and operation of EVO Loudspeakers. The following section may help in resolving some problems that may occur . 1. The front panel is inoperative and does not respond to button pressing: Check the LOCKED indicator .
EVOi.net 27 TROUBLESHOOTING 1 st Flash 2 nd Flash Digit Digit Meaning 2 1 Speaker Over Current. (Short Circuit on amplifier output). Contact Authorized Service Representative. 2 2 Speaker Over T emperature. (Heatsink temperature too hot). Reduce level to allow speaker to cool.
EVOi.net 28 TECHNICAL DA T A E V O i .net S p e c i f i c a t i o n s Inputs: 2 channels, Max. level +20dB (7.5V rms), 8k Ohms impedance, Electroni- cally Balanced, XLR connectors, pin 2+ 1 Dedicated .
EVOi.net 29 JBL Limited Warr anty The JBL Limited W arranty on professional loudspeaker products (except for enclosures) remains in effect for five years from the date of the first consumer purchase. JBL amplifiers are warranted for three years from the date of original purchase.
EVOi.net 30 NOTES.
EVOi.net 31.
EV Oi.net EVOi.net 32.
SAFETY INFORMA TION AC Operation Fuse . . . . 6 Power Connector . . . . 6 Anti Feedback Control . . . . 4, 15-16, Clearing Anti Feedback Control . . . . 16 Fixed Anti Feedback Control . . . . 4, 15-16 Live Anti Feedback Control . . . . 4, 15-16 Appendix .
A Har man Inter national Company JBL Pr ofessional • 8500 Balboa Boule var d • Nor thridge, CA 91329 www .jblpr o.com Part # 337540-001 © Copyright 2001 JBL Professional • Printed in the USA.
Een belangrijk punt na aankoop van elk apparaat JBL EVOi.net (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen JBL EVOi.net heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens JBL EVOi.net vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding JBL EVOi.net leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over JBL EVOi.net krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van JBL EVOi.net bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de JBL EVOi.net kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met JBL EVOi.net . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.