Gebruiksaanwijzing /service van het product TM9V*MP van de fabrikant Johnson Controls
Ga naar pagina of 40
701379-UIM-C-0712 RESIDENTIAL GAS FURNACE MODELS: TM9V*MP (96% AFUE T wo St age V ariable Speed ECM Multi-position) INSTALLATION MANUAL LIST OF SECTIONS SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DUCTWORK .
701379-UIM-C-0712 2 Johnson Controls Unitary Products SECTION I: SAFETY This is a safety alert symbol . When you see this symbol on labels or in manuals, be alert to the potential for personal injury . Understand and pay particular attention to the signal words DANGER , WA R N I N G , or CAUTION .
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 3 • Furnaces for installation on combustible flooring shall not be installed directly on carpeting, tile or other combustible material other than wood flooring. • Check the rating plate and power supply to be sure that the elec- trical characteristics match.
701379-UIM-C-0712 4 Johnson Controls Unitary Products INSPECTION As soon as a unit is r eceived, it should be inspected for possible dam- age during transit. If damage is evident, th e extent of the damage should be noted on the carrier ’s freight bill.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 5 SECTION II: DUCTWORK DUCTWORK GENERAL INFORMA TION The duct system’s design and installation must: 1. Handle an air volume appropriate for the served space and within the operating parameters of the furnace specifications.
701379-UIM-C-0712 6 Johnson Controls Unitary Products COIL INST ALLA TION COIL/FURNA CE ASSEMBL Y - MC/FC/PC SERIES COILS FURNACE ASSEMBL Y - MC & FC SERIES COILS These coils are factory shipped for installation in either upflow or down- flow applications with no conversion.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 7 Dimension “C” should be at least 2/3 of dimension “D”. See Figure 6. CRITICAL COIL PROJECTION The coil assembly must be located in the duct such that a minimum dis- tance is maintained between the top of the coil and the top of the duct.
701379-UIM-C-0712 8 Johnson Controls Unitary Products HORIZONT AL APPLICA TION A TTI C INST ALLA TION This appliance is certified for line contact when the furnace is installed in the horizontal left or right position.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 9 SECTION III: FIL TERS FIL TER INST ALLA TION All applications require the use of a field installed filter . All filters and mounting provision must be field supplied. Filters must be installed external to the furnace cabinet.
701379-UIM-C-0712 10 Johnson Controls Unitary Products SIDE RETURN Locate the “L” shaped corner loca tors. These indicate the size of the cut- out to be made in the furnace side panel. Refer to Figure 14. Install the side filter rack followi ng the instructions provided with that accessory .
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 11 The furnace must be isolated from the gas supply piping system by closing its individual external manua l shutoff valve during any pressure testing of the gas supply piping system at pressures equal to or less than 0.
701379-UIM-C-0712 12 Johnson Controls Unitary Products SECTION V : ELECTRICAL POWER ELECTRICAL POWER CONNECTIONS Field wiring to the unit must be grounded. Electric wires that are field installed shall conform to the temperature limitation for 63°F (35°C) rise wire when installed in accordance with instructions.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 13 For additional connection diagrams for all UPG equipment refer to “Low V oltage System Wi ring” document available on-line at www .
701379-UIM-C-0712 14 Johnson Controls Unitary Products FIGURE 19: Thermostat Chart - Single S tage Heat Pump with Two S tage V ariable Speed Furnace (Hot Heat Pump or Conventional) Part Numbers: SAP =.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 15 FIGURE 20: Thermostat Chart - T wo S tage AC with T wo S tage V ariable S peed Furnace AC 24C Two Stage Air Conditioner – Two Stage Variable S.
701379-UIM-C-0712 16 Johnson Controls Unitary Products FIGURE 21: Thermostat Chart - T wo S tage HP with T wo St age V ariable S peed Furnace (Hot Heat Pump or Co nventional) O Reversing Valve Energiz.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 17 ACCESSOR Y CONNECTIONS The furnace control will allow power-switching control of various accessories. ELECTRONIC AIR CLEANER CONNECTIO N T wo 1/4” (6.4 mm) spade terminals (EAC and NEUTRAL) for electronic air cleaner connections are located on the control board.
701379-UIM-C-0712 18 Johnson Controls Unitary Products CONDENSA TE DRAIN TERMINA TION A condensate sump pump MUST be used if required by loca l codes, or if no indoor floor d rain is avail able. The cond ensate sump pump must be approved for use with acidic condensate.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 19 FIGURE 24: Upflow Configuration INDUCER ROT A TED FOR LEFT SIDE VENTING UPFLOW AS RECEIVED INDUCER ROT A TED FOR RIGHT SIDE VENTING When drain hose routing changes are required, be sure to cap all un-used openings.
701379-UIM-C-0712 20 Johnson Controls Unitary Products FIGURE 25: Downflow Configuration AIRFLOW AIRFLOW Move rain gutter hose to this position. DOWNFLOW - INDUCER ROT A TED FOR LEFT SIDE VENTING DOWNFLOW - INDUCER ROT A TED FOR RIGHT SIDE VENTING Move pressure switch hose to this position.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 21 FIGURE 26: Horizontal Left Configuration HORIZONT AL - LEFT INDUCER ROT A TED HORIZONT AL - LEFT INDUCER AS RECEIVED AIRFLOW AIRFLOW Move pressure switch hose to this position. NOTE: May require the longer hose that is provided with wider cabinets.
701379-UIM-C-0712 22 Johnson Controls Unitary Products FIGURE 27: Horizontal Right Configuration AIRFLOW HORIZONT AL - RIGHT INDUCER ROT A TED HORIZONT AL - RIGHT INDUCER AS RECEIVED Move rain gutter hose to this position. Move pressure switch hose to this position.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 23 SECTION VII: COMBUSTION AIR AND VENT SY STEM COMBUSTION AIR AND VENT SAFETY This Category IV , dual certified direct vent furnace is designed for resi- dential application.
701379-UIM-C-0712 24 Johnson Controls Unitary Products Dimensions are those requi red in S tandard ASTM D-331 1. Example: An 80,000 BTUH furnace requires 32 feet of pipe and five 90º elbows.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 25 VENT CLEARANCES † A vent shall not terminate directly above a sidewalk or paved driveway tha t is located between two single family dwellings and serves both dwellings. †† 12” (30.5 cm) up from the botto m edge of the structure for T wo- pipe (direct vent) applicat ions per ANSI Z223.
701379-UIM-C-0712 26 Johnson Controls Unitary Products VENT SY STEM This furnace is certified to be installed with one of two possible vent configurations. 1. Horizontal vent system. This vent system can be installed com- pletely horizontal or combinations of horizontal, vertical, or of fset using elbows.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 27 DOWNWA RD VENTING In some applications, it may be neces sary to run the vent pipe and air intake downwards.
701379-UIM-C-0712 28 Johnson Controls Unitary Products An unconfined space is not less than 50 cu.ft (1.42 m 3 ) per 1,000 Btu/ hr (0.2928 kW) input rating for all of the appliances inst alled in that area.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 29 6. An air inlet supply from outdoor s shall be equipped with a means to prevent the direct entry of rain and wind. Such means shall not reduce the required free area of the air supply opening. 7.
701379-UIM-C-0712 30 Johnson Controls Unitary Products Specially Engineered Inst allations The above requirements shall be permitted to be waived where special engineering, approved by the authority having jurisdiction, provides an adequate supply of air for combustion and ventilation.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 31 V erify natural gas input rate by clocking meter. 1. T urn off all other gas appliances and pilots. 2. Run furnace for a minimum of 3 minutes in heating operation. 3. Measure time (in sec) for gas meter to complete 1 revolution and note reading.
701379-UIM-C-0712 32 Johnson Controls Unitary Products ADJUSTMENT OF MANIFO LD GAS PRESSURE & INPUT RA TE Inlet and manifold gas pressure may be measured by connecting the “U” tube manometer to the gas valve with a piece of tubing. Follow the appropriate section in the instructions below.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 33 ADJUSTMENT OF TEMPERA TURE RISE After about 5 minutes of operation, determine the furnace temperature rise. T ake readings of both the return air and the heated air in the ducts, about six feet (1.
701379-UIM-C-0712 34 Johnson Controls Unitary Products T ab le 18: Air Flow Data HIGH / LOW SPEED COOLING AND HEA T PUMP CFM 040A10 060B12 080B12 Jumper Settings High Low High Low High Low COOL T ap A.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 35 SECTION IX: SAFETY CONTROLS CONTROL CIR CUIT FUSE A 3-amp fuse is provide d on the control circuit board to protect the 24- volt transformer from overload caus ed by control circ uit wiring errors.
701379-UIM-C-0712 36 Johnson Controls Unitary Products Heating Cycle When the thermostat switch is set on HEA T and the fan is set on AUTO, and there is a call for heat, a circuit is completed between terminals R and W of the thermostat.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 37 5 RED FLASHES: This fault is indicated if the limit circuit is open for more than fifteen minutes, usually i ndicating that a manual-reset rollout switch has opened. Check fo r proper combustion air, proper inducer operation, and primary heat excha nger failure or burner p roblem.
701379-UIM-C-0712 38 Johnson Controls Unitary Products SECTION XI: REPLACEMENT P ARTS LIST DESCRIPTION MOT OR MOTOR, DIRECT DRIVE BLOWER BLOWER, COMBUSTION 2-ST AG E ELECTRICAL CAP ACITOR, RUN SWITCH,.
701379-UIM-C-0712 Johnson Controls Unitary Produ cts 39 SECTION XII: WIRING DIA GRAM FIGURE 43: Wiring Diagram 1600/2000 CFM MODELS ONLY C PS3 NO ROS1 HI C M GAS VALVE CONTROLS TO AIR CONDITIONER ROOM.
Subject to change without not ice. Published in U.S.A 701379-UIM-C-0712 Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 701379-UIM-B-1211 Y ork Inte rnational Corp.
Een belangrijk punt na aankoop van elk apparaat Johnson Controls TM9V*MP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Johnson Controls TM9V*MP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Johnson Controls TM9V*MP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Johnson Controls TM9V*MP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Johnson Controls TM9V*MP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Johnson Controls TM9V*MP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Johnson Controls TM9V*MP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Johnson Controls TM9V*MP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.