Gebruiksaanwijzing /service van het product 625.3847 van de fabrikant Kenmore
Ga naar pagina of 20
OWNER'S MANUAL MODEL NO. 625.384700 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll-free number.
- WARRANTY- 1 li I I /liJ I Ill li I I _ I Ill I / I lill_ I FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM = = (except filter cartridges and R.
- TABLE OF CONTENTS - Where To Install the RO System ........ 4 Tools and Materials Needed ........... 4 Installation Steps .................... 5- 9 Cold Water Supply .................. 5 Drain Adapter ..................... 6 Faucet .................
- WHERE TO INSTALL THE RO SYSTEM - The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall sur- face, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting.
- STEP 1: INSTALL COLD WATER SUPPLY FITTING - Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak- tight connection to the RO 1/4" tubing (see FIG. 8, page 8). A typical connection using the included water supply fitting is shown in FIG.
- STEP 2: INSTALL DRAIN ADAPTER - • Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 18, is preferred. However, if that is not pos- sible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p-trap (FIG.
- STEP 3: INSTALL FAUCET (cont.)- B. ASSEMBLE FAUCET 1. If not already assembled, install the rubber washer, spacer, flat (or lock) washer and hex nut onto the threaded faucet stud. 2. Apply Teflon tape to the end of the faucet stud. Turn the tubing adapter with a blue collet onto the stud and hand tighten, then wrench 1/4 turn only.
- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS - 1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to FIG. 8, run the loose section (connected to faucet barb fitting) of black 3 / 8" tubing from the faucet to the drain adapter, with a black collet, installed on page 6.
- STEP 6: SANITIZING, PRESSURE TESTING & PURGING - SANITIZING Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PREFILTER Water from the cold supply pipe enters the RO as- sembly prefilter first (FIG. 8 and schematic below).
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - To keep your reverse osmosis system operating and producing high quality water, you must make sure supply water is always within the limits shown in the specifications. Good supply water helps to assure longer life from the RO membrane cartridge, prefilter and postfilter cartridges.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - 2. Press inward while turning the RO cap to the left (_) to remove from the bracket/membrane housing. 3. Use a pliers, or heavy wire made into a hook, to pull the RO cartridge from the housing. Note: Sanitizing is recommended after servicing in- ner parts of the system (see page 9).
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - TUBING CONNECTION (continued) If tubing other than tubing supplied with the system is used, be sure it is of high quality, exact size and roundness with a smooth surface. AUTOMATIC SHUTOFF SERVICE If the shutoff assembly requires service, be sure to reassemble parts exactly as shown in FIG.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NO. 625.384700 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges.
- DIMENSIONS and SPECIFICATIONS - 15" Supply water pressure limits ........................ 40 - 125 psi Supply water temperature limits ..................... 40 - 100 °F Maximum total dissolved solids (TDS) ............... 2000 ppm Maximum water hardness @ 6.
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Model No, 625.384700 33 !DRA , t ADAPTER 34 ! Bracket!Membrane Housing PUSH - IN FITrlNGS ] CO et 24 I 26 1/4" Tubing _ U 35 _10_ _ o-ring seals j3 I" I I 21 20 19 1 I I I I I .
Key NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 - REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Part Number 7205350 7207920 7185788 42-34702 71771.
- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM - REMOTE RO INSTALLATION (storage tank not shown) Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet.
19.
OWNER'S MANUAL MODEL NO. 625,384700 The model number of your reverse osmosis system is found on the rating decal. This decal is on the top of the bracket.
Een belangrijk punt na aankoop van elk apparaat Kenmore 625.3847 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Kenmore 625.3847 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Kenmore 625.3847 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Kenmore 625.3847 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Kenmore 625.3847 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Kenmore 625.3847 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Kenmore 625.3847 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Kenmore 625.3847 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.